background image

Program P1 – Lower temperature at night (night-time heating)

By activating programme P1, the temperature is automatically reduced by 5 °C for 7 hours.

Note: 

the programme must be activated when you require the lower temperature: e.g. 11 PM.

P1 must be activated at the time you require the lower temperature at night. When P1 is activated, the reduction
in temperature will be activated in the evening/night automatically.

If you see a green light + red light blinking

when this module is selected, the start time for night-time heating 

             

 

has not been specified

Activating P1 – Night-time heating

1.

     

.

The programme must be activated at the time you wish to reduce the temperature at night (e.g.  10.30 PM)

2.     

.

Turn the control dial to P1 (P1- set to the light)

3.     

Press the control dial once. If the time is not given, a green light will blink!

4.     

.

Press and hold in the control dial for 2 seconds until the green light blinks

5.     

Turn the control dial to the required temperature (22 degrees) and confirm by depressing the control dial.

Programme

 

P1

 

will then reduce the temperature from 22 °C to 17 °C  for 7 hours. After 7 hours, the radiator will warm up 

to 22°C

If the temperature is adjusted when night-time heating is set, the updated temperature will be reduced by 5°C.

If a different

 

“comfort”

 

temperature is required, e.g. 22°C, this can easily be adjusted by setting a new

 

“comfort”

 

temperature (e.g. 20°C.

 

The reduced night-time temperature will then be 15°C).

Changing starting time for P1 – Lower temperature at night (night-time heating)

1. 

   

 

.

Reactivated when the required starting time for night-time heating is set: e.g. 10 PM

2.     

   

Follow steps 2 – 5 under activating night-time heating.

Manuel mode

When activating the manual mode, the desired temperature is set by turning the control dial.
The radiator is heating up when the red light is on. When the green light is on, the room has reached the 
settemperature.

1.     

      

Turn the control dial to the hand symbol

and press once to confirm

Set the desired temperature you require. Adjust for night-time heating and/or set the temperatureto 5°C if the radiator
is set to guard against frost in a shed or holiday home.

Open window

This setting is set to Off by default. By registering an open window, it makes it possible to detect

 

an open window 

(registering a suddenly change in temperature). When the radiator senses a window is open,

 

the temperature is 

automatically set to anti-frost mode (7°C). When the window is closed– i.e. when the zone temperature starts to 
increase – the radiator automatically reverts to the previous set temperature.

Activate / Deactivate Open window

1.     

        

.

Turn the control dial to the hand symbol –

Press to confirm

2.     

.

Turn the control dial to 13°C

3.     

Status

 

 

Press in the control dial for 1 second twice

 

 

the green light will blink

.

        a. 

   

Open window is activated – Green light shows

        b. 

   

Open window is deactivated – Red light shows

4.     

.

Turn Open window off or on

        a. 

   

Turn the control dial to the left to turn off – The LED light will turn red–Press the dial in to confirm. The green 

        

light will blink

.

        b. 

   

   

Turn the control dial to the right to turn on – The LED light will turn green – Press the dial in to confirm. The 

       

green light will blink

.

5.    

   

When either is turned off or on – adjust to the desired temperature.

10

Trigger:
When 5 (or more) °C drop is detected during 10 minutes period.

indication will inform about detected open window. During this stage heater will be

 

inactive.

  

Summary of Contents for ET ECO SX.2

Page 1: ...ower cut occurred It will start heating up again as soon as the power is on If the temperature is changed the light will blink red indicating a power outage To adjust the temperature you must follow Step 1 Starting the radiator for the first time If the radiator is turned off for a long period e g during the summer the light will blink red when it is turned on again follow the process for Step 1 Chi...

Page 2: ...et e g 10 PM 2 Follow steps 2 5 under activating night time heating Manuel mode When activating the manual mode the desired temperature is set by turning the control dial The radiator is heating up when the red light is on When the green light is on the room has reached the settemperature 1 Turn the control dial to the hand symbol and press once to confirm Set the desired temperature you require Ad...

Page 3: ...programmes and services to the factory settings so it can be set up as new Factory settings 1 Turn the control dial to the hand symbol Press to confirm 2 Turn the control dial to 11 C 3 Press the control dial in for 1 second two times The green and red lights will blink 4 Press and hold in the control dial for 3 seconds until the green light blinks The radiator is now reset to its factory settings ...

Page 4: ...confirm it is set Repeat the above process until you have set all the times and temperatures required during your Day or W eek schedule When the programme is active the temperature will be adjusted at the times specified irrespective of the temperature showing on the control dial until you choose another programme or stop the programme Erase saved programme settings 1 Turn the control dial to P2 P2 ...