background image

 

 

Page 10/29  

Vidar 

Installation

 

Guide

 

Adaptive Recognition 

America 

Adaptive Recognition 

Hungary 

Adaptive Recognition 

Nordic 

Adaptive Recognition 

Singapore 

[email protected]

 

WWW.ADAPTIVERECOGNITION.COM

 

Here's an exact example of Transversal installation: 

 

 

13.

 

Access control - Typical for access control 

 

Typical height (h): At least 1 meter above the headlights of the car 

 

Distance from the side of the road (d): Maximum 1 or 2 meters 

 

ANPR range: typically 4 m 

 20 m  

 

Horizontal rotation - 

PAN (β): max. 25°

 

 

Vertical rotation: as low as possible, tilted slightly down  

 

Camera should be pointed on the road, below the horizon 

 

Sun should not shine in the camera or from behind the camera 

 
 

Transversal installation geometrics with exact values 

Access control with range values 

Summary of Contents for Vidar

Page 1: ...guide contains an overview of the hardware and required components suggested scenarios and step by step guide for installation and safety and maintenance instructions Copyright Adaptive Recognition Inc All rights reserved 14 03 2023 ...

Page 2: ...2 Hardware Overview 4 3 Required components 5 4 Recommended installation 6 5 Installation steps 12 5 1 Power Specifications 12 5 2 Cable Layouts 13 5 3 Hardware installation 14 5 4 Optional wiring 16 6 Software Requirements 17 7 Accessing the Camera 17 8 Safety 19 9 Maintenance Storage 20 10 Appendix 21 10 1 Recommended Power Supply 21 10 2 Cable Layouts 21 10 3 Junction Box 23 10 4 Adding Alterna...

Page 3: ...ng the camera on https www youtube com watch v v_6v2UZ5lHk list PLFiWaPY4v7LwJKqy5Jpdbq9YdhmgU10R Z index 2 2 VIDAR ANPR LPR Camera Setting the IP Address and Reaching the GUI In this video we guide you through connecting the VIDAR ANPR camera to a PC or laptop centralized router switch to set it up by covering the following Setting a static IP address Reaching the device s graphical user interfac...

Page 4: ...gary Adaptive Recognition Nordic Adaptive Recognition Singapore REQUESTINFO ADAPTIVERECOGNITION COM WWW ADAPTIVERECOGNITION COM 2 HARDWARE OVERVIEW Green status LED Light sensor Red status LED Sunshield Wall bracket Camera with bracket Camera front Camera optics Built in illuminator Laser ...

Page 5: ...x contains Vidar camera Bracket Optional parts GPIO cable Junction Box Synchronized External Illuminator Required for camera operation These are not included in the box you can purchase it directly from Adaptive Recognition Power cable Ethernet cable Assets needed Size 3 Allen key PC to reach web interface Magnet min I2I0 mT strength to recover cameras when IP is lost Tools for Junction Box Philli...

Page 6: ...NITION COM WWW ADAPTIVERECOGNITION COM 4 RECOMMENDED INSTALLATION 1 Please make sure that the camera is installed centered and it does not roll neither to the left nor right Roll must be 0 You can check the ROLL on the camera GUI here Maintenance Sensors 2 Connect the cables to the designated connectors Seal the unused cable endings with end sleeves before connecting to power ...

Page 7: ...d cables are tightened properly and the unused connectors are capped 5 Failures caused by inappropriate installation could void the warranty 6 Please note that cameras installed inadequately may underperform in reading accuracy and vehicle detection 7 Avoid east west orientation of the camera Sun can make reading difficult at certain times of the day 8 The camera should be lowered below the horizo...

Page 8: ...installation when camera placed above the lane Vertical positioning h o typically 4 9 m above the lane o 2 5 4 m internal Horizontal positioning center of the lane Vertical rotation TILT α 20 40 Typical range r o external 15 20m o internal 4 10m Camera should be pointed below the horizon Sun shouldn t be seen Typical application areas external highway tolling internal parking Overhead installation...

Page 9: ... example of Overhead installation 12 Transversal installation when the device is installed on a pole near the road and it has to be Typical height h 4 8m Distance from the road d 1 2m Vertical rotation TILT α 20 40 Horizontal rotation PAN β 10 20 Typical range r 15 20m Typical field of application fixed installation on a road Overhead installation geometrics with exact values Transversal installat...

Page 10: ...ontrol Typical for access control Typical height h At least 1 meter above the headlights of the car Distance from the side of the road d Maximum 1 or 2 meters ANPR range typically 4 m 20 m Horizontal rotation PAN β max 25 Vertical rotation as low as possible tilted slightly down Camera should be pointed on the road below the horizon Sun should not shine in the camera or from behind the camera Tran...

Page 11: ...Recognition America Adaptive Recognition Hungary Adaptive Recognition Nordic Adaptive Recognition Singapore REQUESTINFO ADAPTIVERECOGNITION COM WWW ADAPTIVERECOGNITION COM Here s an exact example of Access control Access control with exact values ...

Page 12: ...24Vac output 2 6A IP30 Procurement source TME PSS63 230 24V Product Glass Fuse Current Rating 3 15A Fuse Type Time delay Slow Blow Fuse Size 5 mm x 20 mm Voltage Rating AC 250 VAC Mounting Style Holder Clips Minimum Operating Temperature 55 C Maximum Operating Temperature 125 C Please use the following fuse protection or equivalent Littelfuse Cartridge Fuses 02183 15MXP Distributor Mouser 576 0218...

Page 13: ...ted to AC1 and AC2 Both signals are connected to two pins a and b to allow for larger effective cable diameter two wires for each potential AC1_a and AC1_b are connected in the device AC2_a and AC2_b are connected in the device See Appendix for more details at section 10 2 1 Ethernet 8 pos M12 X coded Female RJ45 Wire colours and RJ45 positions referto thosein thesupplied standardETH cable Usequal...

Page 14: ...ition Nordic Adaptive Recognition Singapore REQUESTINFO ADAPTIVERECOGNITION COM WWW ADAPTIVERECOGNITION COM 5 3 HARDWARE INSTALLATION Bracket Details and Sizes Camera fastening screws To ensure proper mounting of the camera with bracket please use the largest possible fastener e g fastening screw with DIA 8 mm ...

Page 15: ...OGNITION COM Adjust the bracket 1 Loosen the camera fastening screw on the bottom of the bracket Use size 5 Allen key 2 Adjust the bracket into the desired position Tighten the screw back Mounting Thebracketcan be mounted into differentsurfaces Useappropriatescrews forinstallationaccording to the mountable surface Do not overtighten the screws Failures due to inappropriate installation void the wa...

Page 16: ... COM WWW ADAPTIVERECOGNITION COM 5 4 OPTIONAL WIRING I O 12 pin 12 pos M12 A coded Female Connector pinout and wire color coding Colours refer to those in the supplied standard I O cable See Appendix for more details at section 10 2 3 Trigger specifications Input min 5V max 12V Logic Output min 5V max 12V max 10mA Pulse width min 1 ms Schematic for triggering Be aware of the polarity ...

Page 17: ...to the newest available version 7 ACCESSING THE CAMERA Steps of accessing the web interface of the camera from a browser 1 Connect the camera to a computer or network switch then power on the camera After it is turned on both status LEDs red and green on the camera front are turned on while the camera is booting After finished the green status LED flashes two times while the red one turns off sign...

Page 18: ...ed o proxy is set in the browser or the browser is not set to offline If these obstacles are checked and there is still no reply power off then on and enter the previous ping command again 6 Start a browser then enter the default IP address of the camera into the address bar http 192 0 2 3 After this the camera starts with administrator privileges ready to be setup and configured Next step is the ...

Page 19: ...the screws Failures due to inappropriate installation void the warranty The camera must only be installed on a stable surface For cabling use quality outdoor certified cables Improper cabling causes warranty to void Water may enter into the camera inside through not properly sealed connectors To maintain the camera s watertightness please make sure that connected cables aretightened properly and t...

Page 20: ...t because it was specially designed to provide proper air cooling The cameras should be stored in low humidity environment in temperature range of 40 C to 55 C Always use the sealing caps on the connectors to keep the camera unit waterproof If you miss to use it the warranty will be void The maintenance of the devices is recommended on a quarterly basis In case of extreme weather conditions more o...

Page 21: ...ed one is an AC230V AC24V transformer the other is an AC230V 36V DC power supply Both are suitable for powering a Vidar camera under suitable environmental conditions AC DC power supply Type Stontronics SRS 75 36 Main features 75W Universal AC input 100 240Vac 36V DC output Procurement source Farnell 3377270 AC AC transformer Type BREVE PSS 63 230 24V Main features 63W 230Vac input 24Vac output 2 ...

Page 22: ...tion America Adaptive Recognition Hungary Adaptive Recognition Nordic Adaptive Recognition Singapore REQUESTINFO ADAPTIVERECOGNITION COM WWW ADAPTIVERECOGNITION COM 10 2 2 Ethernet 8 pos M12 X coded Female RJ45 10 2 3 I O 12 pin 12 pos M12 A coded Female ...

Page 23: ...TINFO ADAPTIVERECOGNITION COM WWW ADAPTIVERECOGNITION COM 10 3 JUNCTION BOX A 12 pin user cable M12 binder female connector at one end and a stripped end on the other is required to connect the camera to the Junction Box This I O cable is not included by default with the camera However you can purchase it directly from Adaptive Recognition PART COMBUY OTH0326 ...

Page 24: ...nd Sharing Center 4 Click on the network connection you want to add an IP address for to which the camera has been connected and select Properties 5 Select Internet Protocol Version 4 TCP IPv4 click on Properties and selectthe Alternate Configuration tab 6 Select User configuredandentere g the192 0 2 54IP address and255 255 255 0as Subnet mask as shown on Figure 1 7 Click OK in the opened windows ...

Page 25: ... magnet is in proper position the green indicator led on the front of the camera will start flashing very fast Remove the magnet Enter the web interface at the 192 0 2 3 default IP Entering Recovery mode to Vidar camera Starting of the Recovery mode can be implemented by magnetization in the following way By magnetization 1 Power off the camera 2 Touch a magnet not included to the back of the came...

Page 26: ... the bottom of the device CAUTION The device is equipped with an infra led illumination unit The human eye will not or slightly see this light coming from the LED s Do not look into the illumination unit directly from close range or for more than 100 seconds Eyes can be damaged by not taking these precautions The sticker indicating the Name IP address MAC address and the Serial Number of the camer...

Page 27: ...ant with EC Directive 2002 95 EC on the Restrict of Certain Hazardous Substances in Electrical and Electronic Equipment commonly known as the EU RoHS Directive Compliance with RoHS means that where the product falls under the scope of the EU RoHS Directive the product does not contain the following substances Mercury Hg 0 1 Lead Pb 0 1 Cadmium Cd 0 01 Hexavalent Chromium Cr 6 0 1 Polybrominated Bi...

Page 28: ...e equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfe...

Page 29: ...ort System ATSS is designed to provide you the fastest and most proficient assistance so you can quickly get back to business Information regarding your hardware latest software updates and manuals are easily accessible for customers via our Documents Site www adaptiverecognition com doc after a quick registration New User If this is your first online support request please contact your sales repr...