1-14
A
LPHA
4000 RBG MNS, P
O
E I
NSTALLATION
M
ANUAL
(PN 1776610301 R
EV
. A)
S
TART
-
UP
Alpha 4000 RBG MNS PoE
Start-up
After installing a sign according to the previous sections, make sure the unit is installed properly by applying power to it. It
may take up to 30 seconds for the loading icon to appear. Then, information similar to the following should display on the
sign if Alpha Net Player is installed.
Sign display
Meaning
ALPHA controller
1199663011 1.2.10
Software part number including revision and build
Sign Serial Number
JY00000000
AMS Product serial number
Serial Address
V 01
Alpha Protocol Type code character serial address in hexadecimal
Serial 9600 8N1
Serial baud rate data bits parity stop bits
IP
10.11.11.254
Current IP address of sign (default will be listed on the sign)
SUBNET
255.255.0.0
Current SUBNET of sign (default will be listed on the sign)
Gateway
0.0.0.0
Current Gateway of sign (default will be listed on the sign)
Port
3001
Current Sign Port (default will be listed on the sign)
1775250301 Kit
1775250302 Kit
A
Knockout For 1.00 Inch
Bushing For Cable Management
1.00 Inch Hole Plug for 1.00 Inch Bushing
For Cable Management
1.00 Inch Bushing For Cable Management
(An Extra Bushing Provided With Kit)