6-4
ARO-1130SA Installation and Hardware Guide
Note:
To load the driver automatically at server bootup, make
sure the
startup.ncf
file includes the
load
command line for
the
cda1000.dsk
driver. (If you also have an Adaptec host
adapter that uses the Adaptec
aic78xx.dsk
driver, make sure
the driver loads after the
cda1000.dsk
driver.)
NetWare 3.12
Follow these instruction only if you are installing NetWare 3.12 for
the first time:
1
Follow the procedures in your NetWare documentation for
installing a new server. (For information on using a CD-ROM
drive on a NetWare server, see Appendix D, Using a CD-ROM
Drive.)
2
When you see the NetWare colon prompt (:), use the
load
com-
mand to install the driver from the appropriate Adaptec
Array1000xA Family Manager Set driver diskette (Disk A or
Disk B). (See Running the Array1000xA BIOS & Driver Selection
Utility on page 3-2 to determine the appropriate driver dis-
kette.)
The correct syntax to load the
cda1000.dsk
driver is
:load [
pathname
]cda1000
(For example,
:load a:\netware\v3_1x\cda1000
)
Note:
To load the drivers automatically at server bootup,
copy the
aspitran.dsk
and
cda1000.dsk
drivers to the
server’s startup directory and modify the
startup.ncf
so
that the proper path to the driver is specified
.
The
aspitran.dsk
driver must reside in the same path as
cda1000.dsk
, because NetWare attempts to load this file
automatically. If you also have an Adaptec host adapter
that uses the Adaptec
aic78xx.dsk
driver, make sure the
driver loads after the
cda1000.dsk
driver.