For detailed instructions on how to use the software, please visit
PROTON WHO
Nature of Violations and Exposure intervals are shown in below table:
User Interface
User can fetch the data from PC/Laptop, also can see data on display by clicking on prompt button.
User can see number of violations, type of violation, time stamps of violations, trip time on the display.
Time stamps can be seen by clicking on the button in steps.
If there are No violations, Tick/OK mark will be displayed on the LCD.
If there are violations, X/not OK mark will be displayed on the LCD.
www.adaptloggers.com
+91-8639739890
https://docs.adaptloggers.com/devices/proton/protonswho/
03
END
hrs
Trip Ended with Violations
Higher Threshold Violation
Recording Ended
Medium Threshold Violation
Lower Threshold Violation
Violation Count
END
hrs
Trip Ended with no violations
Recording Ended
OK
OK
Alarm settings
A
larm T
y
pe
Time
-
Temperature
threshold
P
eriod of
E
xposure
T
y
pe
C
High Threshold
≥
45
˚C
single e
v
ent
1
Hours
Medium Threshold
≥30˚C
cumulati
v
e exposure
10
Hours
Low Threshold
≤
-
0.
5
˚C
single e
v
ent
1
Hours
Type A/B
High Threshold
≥
45
˚C
single e
v
ent
1
Hours
Medium Threshold
≥30˚C
cumulati
v
e exposure
10
Hours
Low Threshold
≥10˚C
cumulati
v
e exposure
2
0
Hours
Type
Rotateq
High Threshold
≥
2
7˚C
single e
v
ent
1
Hours
Medium Threshold
≥17˚C
cumulati
v
e exposure
2 Hours
Low Threshold
≤
-
25
˚C
single e
v
ent
1
Hours
Type
Prevenar
High Threshold
≥
4
0˚C
single e
v
ent
1
Hours
Medium Threshold
≥30˚C
cumulati
v
e exposure
10
Hours
Low Threshold
≤
-
0.
5
˚C
single e
v
ent
1
Hours