![Adamson IS118 User Manual Download Page 7](http://html1.mh-extra.com/html/adamson/is118/is118_user-manual_2846307007.webp)
Adamson Systems Engineering |
Page 7
IS118 User Manual
IS118
Subwoofer Configuration
Applicable Preset
Presets
IS118
All IS118 forward facing
Omni pattern
IS118 FB
Bottom IS118 forward facing,
top IS118 reversed
Cardioid pattern
IS118 FBF
Bottom and top IS118 forward
facing, middle IS118 reversed
Cardioid pattern
The Adamson Load Library
(https://www.adamsonsystems.com/support/downloads-directory/design-and-control/e-
rack/245-adamson-load-library-5-0-1/file
) contains presets designed for a variety of IS118 deployments.
For a master list, please refer the Adamson PLM & Lake Handbook, found on our website.
com/support/downloads-directory/design-and-control/e-rack/205-adamson-plm-lake-handbook/file
When flown in the same array as an IS7, all IS118 presets contain the inherent delay needed to be properly phase-
aligned.
When flown or ground stacked separately, IS118 subs should be phase-aligned using measurement software.
Subwoofer Configuration
100 Hz
35 Hz
0°
180°
180°
90°
90°
100 Hz
35 Hz
0°
180°
180°
90°
90°
IS118 FB
IS118 FBF
Cardioid Dispersion
IS118 EF40
End fire 40”/100cm Distance
from Front Screens
Cardioid pattern