The

 IS118

 (992-0010, 992-5010) comes with 4x Neutrik Speakon™ NL4 connections, wired in parallel. The 2 rear 

connections pass pin 1 +/- to the driver and the 2 front connections pass pin 2 +/- to the driver. 

The 

IS118b

 (992-0011, 992-5011) comes with an external barrier strip mounted to the rear grill.  Terminals 1, +/- are 

passed to the driver, terminal 2, +/- are not connected. 

To operate the IS118b in FB or FBF cardioid mode, swap the front and rear grills by:

1.  Removing the six screws holding each grill to the side rigging pieces

2.  Unclipping the grill with the barrier strip from the rear PCB, and swapping the grills

3. 

Re-clipping the grill with the barrier strip to the front PCB and affix with the same screws

Wiring

IS118 Rear

IS118 Front

IS118b Rear

Summary of Contents for IS118

Page 1: ...nd the IS Series Rigging Manual Use only with the rigging frames accessories speci ed by Adamson or sold with the loudspeaker system This speaker enclosure is capable of creating a strong magnetic eld...

Page 2: ...ia of the applicable EC Directive s in particular Signed at Port Perry ON CA May 1st 2021 Brock Adamson President CEO ADAMSON SYSTEMS ENGINEERING Inc 1401 Scugog Line 6 Port Perry ON L9L 1B2 Ontario C...

Page 3: ...ld with the loudspeaker system This speaker enclosure is capable of creating a strong magnetic eld Please use caution around the enclosure with data storage devices such as hard drives Safety Warnings...

Page 4: ...d has an aluminum rigging system mounted on each corner Without sacrificing lowered resonance to composite material the IS118 is able to maintain a low weight of 39 kg 85 lbs Up to sixteen IS118 can b...

Page 5: ...external barrier strip mounted to the rear grill Terminals 1 are passed to the driver terminal 2 are not connected To operate the IS118b in FB or FBF cardioid mode swap the front and rear grills by 1...

Page 6: ...um quantities of the IS118 per amplifier model are shown below For a master list please refer to the Adamson PLM Lake Handbook found on our website https adamsonsystems com support downloads directory...

Page 7: ...presets designed for a variety of IS118 deployments For a master list please refer the Adamson PLM Lake Handbook found on our website https adamsonsystems com support downloads directory design and co...

Page 8: ...e is made of non plated stainless steel designed to provide exceptional rust and corrosion resistance particularly in high saline environments Environmental sealing Additional protection of the cabine...

Page 9: ...3 dB Components LF ND18 S 18 Neodymium Driver Nominal Impedance LF 8 Power Handling AES Peak LF 500 2000 W Rigging Integrated Rigging System Connection 4x Speakon NL4 2x Front 1 1 2x Rear 2 2 or Barri...

Reviews: