background image

AD

AMS

RITE

MANUF

A

CTURING CO

.

A D A M S   R I T E   P O W E R   S U P P L

A D A M S   R I T E   P O W E R   S U P P L

Y

Y

P

P

A R T   N U M B E R   P S - L R

A R T   N U M B E R   P S - L R

260 Sant

260 Sant

a Fe S

a Fe S

treet, Pomona, CA

treet, Pomona, CA

91767•800.872.3267•Fax 800.232.7329

91767•800.872.3267•Fax 800.232.7329

Page 1 of 10

Need more information? Visit our website at:

www

www

.adamsrite.com

.adamsrite.com

Rev Date: 07/26/10

80-0180-247 REV (H)

OWNERS  MANUAL  AND  INSTALLATION  INSTRUCTIONS

A

AD

DA

AM

MS

S  R

RIIT

TE

E  P

PO

OW

WE

ER

R  S

SU

UP

PP

PLLY

Y

P S - LL R

Document Part Number

80-0180-247 Rev.(H)

ECN 11117

2 - October - 2007

Summary of Contents for PS-LR

Page 1: ... C A 9 1 7 6 7 8 0 0 8 7 2 3 2 6 7 F a x 8 0 0 2 3 2 7 3 2 9 9 1 7 6 7 8 0 0 8 7 2 3 2 6 7 F a x 8 0 0 2 3 2 7 3 2 9 Page 1 of 10 Need more information Visit our website at www www adamsrite com adamsrite com Rev Date 07 26 10 80 0180 247 REV H OWNERS MANUAL AND INSTALLATION INSTRUCTIONS A AD DA AM MS S R RI IT TE E P PO OW WE ER R S SU UP PP PL LY Y P S L L R Document Part Number 80 0180 247 Rev ...

Page 2: ...OWER SUPPLY ___________________________6 1 8 STEP 8 INSTALL BACKUP BATTERIES OPTIONAL ____________________________6 1 9 STEP 9 PS LR WIRING DIAGRAM __________________________________________7 1 10 STEP 10 BASICDOOR WIRING DIAGRAM____________________________________8 1 11 STEP 11 WIRE AUTOMATIC DOOR INTERFACE OPTIONAL 9 ___ 1 12 STEP 12 WIRING PRIMARY POWER CONNECTION 9 2 DESCRIPTIONS PART NUMBERS ...

Page 3: ...evice remains unlatched until the controlling switch is released An optional mode is available allowing both retraction timers to activate in response to closure of either switch The Adams Rite Power Supply is listed as an Exit Device Access Control System unit to UL305 and UL1012 requirements for power supplies and CAN CSA C22 2 Exit devices under the system control remain latched during a comple...

Page 4: ...dip switch SW1 Single Input Sequential Operation Factory Setting Application Control one opening Operation Either input retracts Exit Device 1 immediately followed by Exit Device 2 Dual input Independent Operation Application Control two separate openings Operation Input IN1 retracts Exit Device 1 Input IN2 retracts EXIT DEVICE 2 1 3 STEP 3 SET HOLD OPEN TIMES The Adams Rite Power Supply has two h...

Page 5: ... alarm control connect as follows Remove the jumper wire factory installed between positions 9 and 10 Fire of the J3 terminal block Connect the fire alarm normally closed relay contacts to positions 9 and 10 Fire of the J3 terminal block Closed relay contacts indicate NO ALARM CONDITION When a fire alarm occurs the controlled exit devices will immediately latch secure Exit Devices remain latched d...

Page 6: ...nd two 12V 7AH batteries such as EverOn EVA12 7 5F batteries or equivalent An orange jumper block has been installed into the BATT BACKUP connector of the Power Supply circuit board Remove this jumper by pulling the orange jumper free from the circuit board Install the Battery Backup System circuit board in the location shown below Mounting points are available in the enclosure for the Battery Bac...

Page 7: ...as relay contacts that let the automatic door opener know the latch state The relay contacts are closed when the latch is fully retracted The relay contacts open when the latch is extended Connect the automatic door opener as shown in the figure below 1 12 STEP 12 WIRING PRIMARY POWER CONNECTION J4 Connection For the 115 230 VAC power input terminal block J4 will accommodate up to 12AWG wire Conne...

Page 8: ...proximately 44 OHMS 28 5VDC when powered Black Red Wires 2 OHMS 6VDC when powered Microswitch Blue wires set on Normally Closed Can be measured from Two Wire Driver Board Solenoid wires do not need to be removed from board If Microswitch is Open when no power applied terminals may be set Normally Open Terminal Connectors are loose or Microswitch is failing and need replacing 2 3 PS LR VALUE READIN...

Page 9: ...sed Switch becomes normally open when powered applied Verify revision on Two Wire Driver Board If lower than REV H recommend replacement Also check for shorts in the wiring and if fuses are blown in the PS LR 3 2 Q I HAVE BLOWN FUSES IN MY PS LR A If new install Check for shorts in the wiring particularly around the exit device and hinge Check for rods binding If existing hardware verify revision ...

Page 10: ...rts There is no Fire Alarm connected between J3 9 and J3 10 or the factory installed jumper between J3 9 and J3 10 is removed IN1 AND IN2 LIGHTS DO NOT LIGHT IN RESPONSE TO INPUT SWITCHES An open connection in the field wiring exists between the Adams Rite Power Supply and control switch used for activating the latch solenoids A defective control switch exists on J3 1 and J3 2 or J3 3 and J3 4 OUT...

Page 11: ...is in line with the transformer output 28VDC Little Fuse P N 213004 MXP Adams Rite Mfg P N 29 0667 F2 3 15A 250V 5X20MM 202 I2 t SLOW BLOW Fuse F2 is in line with the transformer input 120VAC 230VAC Little Fuse P N 2133 15 MXP Adams Rite Mfg P N 29 0668 BBK LR FUSES BBK LR BATTERY BACKUP CHARGER FUSE IS THE SAME AS F1 ABOVE FUSE REPLACEMENT MUST BE THE SAME RATING Fuse F3 is not user serviceable I...

Page 12: ...0 2 3 2 7 3 2 9 4 2 Connector Signal Descriptions 4 2 1 Connector J1 BATTERY BACKUP PIN DESCRIPTION 1 Power In 28VDC returned from battery charging system 2 Power Out 28VDC supplied to battery charging system 3 Ground 4 2 2 Connector J3 FIELD WIRING PIN DESCRIPTION 1 2 INPUT 2 Normally open activation switch 3 4 INPUT 1 Normally open activation switch 5 EXIT DEVICE 2 Coil return 6 EXIT DEVICE 2 28...

Reviews: