Orientation
•
Standard color
•
Alternative color
•
Index
(Log channel number)
•
Interval
(for time diagram)
The parameters of the display elements differ greatly depending on the type of display
and are explained below for the individual display types.
Common parameters of all display elements
Most parameters apply to all display elements and are listed below.
Parametername
Default value
Range
Unit
Show[N]
Numeric 0, Numeric
1, Numeric 2, Nu-
meric 3, Numeric 4,
Numeric auto,
Bar
chart, LED, Time di-
agram, Drag indica-
torr
Color change func-
tion[N]
Off,
Hysteresis,
Window
Switching points[N]
0 ... 1
float
’Unit’
Label position[N]
Left
Left, Right,
Above, Below
top[N]
10
5 ... 235
Pixel
left[N]
10
5 ... 315
Pixel
Height[N]
20
10 ... 220
Pixel
Width[N]
20
10 ... 300
Pixel
Standard color[N]
Green
Red,
Green,
Blue,
Cyan, Magenta, Yel-
low, Orange, White,
Black, Grey
Alternate color[N]
Red
Red,
Green,
Blue,
Cyan, Magenta, Yel-
low, Orange, White,
Black, Grey
Index channel[N]
1
1 ... 32
Interval
1
1 ... 65535
s
[N] is the 1-based index of the display element [1...40].
With the parameter
Show[N]
the type of presentation can be selected.
The parameter
color change function[N]
determines whether and after which func-
tion the alternative color is used to represent the value from the channel.
The switching points define the limit values for the color change function.
They have the same unit as the value of the channel.
19