- 9 -
Customer telephone helpline: 08448 809301
Helpline email address: [email protected]
CO9073 V3_210711
Use and Care Manual
Eclipse Electric Fire
PLUG REPLACEMENT
(For product fitted with BS Plug)
This appliance is supplied with a BS1363 3 pin plug fitted with a 13 Amp fuse.
Should the fuse require replacement, it must be replaced with a fuse rated at
13
Amp
and approved to BS1362.
In the event the mains plug has to be removed/replaced for any reason, please
note:
The wires in the mains lead on this appliance are coloured in accordance with the
following code:
Green and Yellow
-
Earth
Blue
-
Neutral
Brown
-
Live
THIS APPLIANCE MUST BE EARTHED
As the colours may not correspond with the markings identifying the terminals in your
plug proceed as follows.
The green and yellow wire must be connected to the terminal in the plug which is
marked with the earth symbol or with the letter E or coloured green & yellow.
The blue wire must be connected to the terminal marked N or coloured black.
The brown wire must be connected to the terminal marked L or coloured red.
Important - any cut off plug should be disposed of safely to prevent hazard. There is a
danger of electric shock if a cut off plug is inserted into a socket outlet.
APPLIANCE DATA
Supply Voltage; 220
– 240V~, 50Hz
Rated Power: 2000W
Fuse (BS Plug) Rating: 13 AMP
Lighting: 5W LED Array (non serviceable)