background image

 

P a g e

11

 

 

© Adam Equipment Company 2009

 

 

9.0  WARRANTY INFORMATION 

 

Adam Equipment offers Limited Warranty (Parts and Labour) for components that fail due to defects in 

materials or workmanship.  Warranty starts from the date of delivery. 

 

During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or 

Adam  Equipment  Company.  The  company  or  its  authorised  Technician  reserves  the  right  to  repair  or 

replace the components at any of its workshops depending on the severity of the problem. However, 

any  freight  involved  in  sending  the  faulty  units  or  parts  to  the  service  centre  will  be  borne  by  the 

purchaser. 

 

The warranty will cease to operate if the equipment is not returned in the original packaging and with 

correct  documentation  for  a  claim  to  be  processed.  All  claims  are  at  the  sole  discretion  of  Adam 

Equipment. 

 

This  warranty  does  not  cover  equipment  where  defects  or  poor  performance  is  due  to  misuse, 

accidental  damage,  exposure  to  radioactive  or  corrosive  materials,  negligence,  faulty  installation, 

unauthorised  modifications  or  attempted  repair  or  failure  to  observe  the  requirements  and 

recommendations as given in this User Manual. 

        

Repairs  carried  out  under  the  warranty  does  not  extend  the  warranty  period.  Components  removed 

during the warranty repairs become the company property. 

        

The  statutory  right  of  the  purchaser  is  not  affected  by  this  warranty.  The  terms  of  this  warranty  is 

governed by the UK law. For complete details on Warranty Information, see the terms and conditions 

of sale available on our web-site. 

 

 

Summary of Contents for WBW 16/35a

Page 1: ...cycled materials and environmentally friendly packaging where possible As part of this initiative we have developed a short manual that uses less paper and ink to describe the main functions of your new Adam indicator scale A complete version is available at www adamequipment com Thank you for your support of Adam Equipment and we hope that you enjoy your new scale ...

Page 2: ... Adam Equipment Company 2009 ...

Page 3: ... 2 0 OPERATION 2 2 1 NUMERIC ENTRY METHOD 2 2 2 ZEROING 2 2 3 TARING 2 2 4 WEIGHING 3 2 5 CHECK WEIGHING 3 3 0 RS 232 SPECIFICATION 4 4 0 CALIBRATION 4 5 0 ERROR CODES 5 6 0 SPECIFICATIONS 6 7 0 ERROR MESSAGES 9 8 0 MENU STRUCTURE 10 9 0 WARRANTY INFORMATION 11 10 0 SERVICE INFORMATION 12 ...

Page 4: ...it of weight that was selected last NOTE the scale can be operated from the battery If desired the battery life is approximately 50 hours When the battery needs charging a symbol on the display will turn on The battery should be charged for 12 hours for full capacity 2 0 OPERATION 2 1 NUMERIC ENTRY METHOD To set a value when required use the keys as given below Limit key to increase the flashing d...

Page 5: ... high limit The user will be asked for the password if the current check weighing password is anything other than 0000 See the parameter F4 PS in menu structure Enter the correct password using the numeric entry method as mentioned in section 2 1 If the password is 0000 it will display the last used high limit The HI symbol will appear on the display Press Tare to accept the displayed high limit o...

Page 6: ...f test Scale will show P Enter code number 0000 using the numeric entry method see section2 1 and press Tare This will take you directly to the calibration section Display will show UnLoAd Remove all weight from the pan and then press the Tare key when the scale is stable After the Zero point is set the display will show Ld xx Place the suggested calibration mass on the pan It is best to use a wei...

Page 7: ...hen zeroing the scale Platform is not installed Improper calibration of the scale Damaged load cell Damaged Electronics Err 6 Err 6 Err 6 Err 6 A D count is not correct when turning the scale on Load cell is damaged Electronics is damaged Err 8 Err 8 Err 8 Err 8 High limit input error Low limit is set first then the high limit is set lower than the low limit and high limit not equal to zero Err 9 ...

Page 8: ...ograms Maximum Capacity 2 000 kg 4 000 kg 8 000 kg 16 000 kg Tare Range 2 000 kg 4 000 kg 8 000 kg 16 000 kg Readability 0 0002 kg 0 0005 kg 0 001 kg 0 002 kg Repeatability S D 0 0002 kg 0 0005 kg 0 001 kg 0 002 kg Linearity 0 0004 kg 0 001 kg 0 002 kg 0 004 kg Grams Maximum Capacity 2000 g 4000 g 8000 g 16000 g Tare Range 2000 g 4000 g 8000 g 16000 g Readability 0 2 g 0 5 g 1 g 2 g Repeatability ...

Page 9: ...S D 0 01 oz 0 02 oz 0 05 oz 0 1 oz Linearity 0 02 oz 0 04 oz 0 1 oz 0 2 oz Pounds Ounces Maximum Capacity 5 lb 0 00 oz 9 lb 0 00 oz 18 lb 0 0 oz 35 lb 0 0 oz Readability 0 01 oz 0 02 oz 0 1 oz 0 1 oz Repeatability S D 0 01 oz 0 02 oz 0 1 oz 0 1 oz Linearity 0 02 oz 0 04 oz 0 2 oz 0 2 oz OTHER SPECIFICATIONS Units of measure WBW M kg g WBW WBW a kg g lb oz lb oz Tare Full range Stabilisation Time 2...

Page 10: ...CD digital display with capacity tracker and symbols for units Scale Housing IP 65 Sealed ABS Plastic housing with Stainless Steel pan Pan Size 210 x 173 mm Overall Dimensions wxdxh 231 x 265 x 153 mm Net Weight 3 3 kg 7 26 lb Applications Weighing Scales Functions Weighing Check weighing ...

Page 11: ... on the platform when turning the indicator on Excessive weight on the platform when zeroing the indicator Platform is not installed Improper calibration of the indicator Damaged load cell Damaged Electronics Err 6 A D count is not correct when turning the indicator on Load cell is damaged Electronics is damaged Err 7 Percent input error Percent function is entered with no reference mass on the pl...

Page 12: ...P a g e 10 Adam Equipment Company 2009 8 0 MENU STRUCTURE ...

Page 13: ... the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted re...

Page 14: ...her methods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready reference Model name of the scale WBW_____ Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of t...

Page 15: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to oper...

Page 16: ...s Medical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features ...

Reviews: