After pressing
[Tare]
↵
,
‘noload’
should appear on the display. Use the
directional button
⭡
to switch to
‘load1’
and set the desired weight limit of the
test object to be placed on the scale using the
⭡
or
⭣
directional buttons and
the
⭢
directional key to move to the next digit. Press the
[Tare]
↵
key to
confirm.
After pressing
[Tare]
↵
,
‘Load’
will appear on the display. Place the
calibration test weight that matches the weight previously entered onto the
scale weighing pan and press the
[Tare]
↵
key to confirm.
Pressing Tare should bring up the
‘Load 2’
option on the display. Follow the
same procedure as before by setting a new weight and adding the
appropriate calibration weight and press the
[Tare]
↵
key to confirm.
Pressing
[Tare]
↵
will reconfigure the scale and bring the user back to the
regular weighing mode.
6.0 TROUBLE
SHOOTING
No.
Problem
Cause
Solution
1
Forks cannot ascend
to the maximum
height
Inadequate hydraulic oil in the
chamber.
Refill oil chamber. See Figure 1.
2
Forks can not be
raised
No hydraulic oil.
Oil is not clean.
Refill oil chamber. See Figure 1.
Change oil
3
Forks can not
descend
Position of the goods are to one
side of the truck
Relocate load.
4
Oil spillage
Aging or damaged seals.
Call for Service.
5
Forks descend
when the trigger is
not in descend
position
The oil could be unclean
Some parts of the hydraulic
system are damaged.
Change the oil.
Vent the air.
Call for Service.