background image

 

 

 

 

 

 

 

17

 

© Adam Equipment Company 2012

 

 

9.1

 

ERROR

 

MESSAGES 

If an error message is shown, repeat the step that caused the message. If the error 

message is still shown then contact your dealer for support. 

 

DISPLAYED MESSAGE 

DESCRIPTION 

Err  

Measured height is above 
210cm/82.5 inches 

UNDER 

Measured height is below 
80cm/31.5 inches 

Err H 

Calibration weight value 
used too high 

Err L 

Calibration weight value 
used too low 

- - - - - - 

Weight on top pan exceeds 
300kg/660Lbs 

 

 

10.0 

TECHNICAL

 

SPECIFICATIONS 

 

Model  

MUW 300L 

Maximum Capacity 

300kg/660Lbs 

Readability 

0.05kg/0.1Lbs 

Repeatability (s.d.) 

0.1kg/0.2Lbs 

Linearity ± 

0.1kg/0.2Lbs 

Units of Height 

Cm, inches, feet and inches 

Height range 

80cm – 210cm/ 31.5 - 82.5 inches 

Units of Weight 

Kg, lb’s, lb’s and ounces 

Power Supply 

12vDC @800ma or Internal 

rechargeable 6vDC battery 

Overall  Dimensions 

w x d x h 

0.38m x 0.6m x 2.3m 

15 x 23.6 x 90.2 inches 

 

All manuals and user guides at all-guides.com

Summary of Contents for MUW 300L

Page 1: ...1 Adam Equipment Company 2012 Adam Equipment MUW HEALTH AND FITNESS SCALE USER MANUAL P N 7 00 6 6 0229 Revision A July 2012 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...TS 9 5 7 CLEARING A PREVIOUS RESULT 9 6 0 PARAMETERS 10 6 1 SETTING THE BACKLIGHT OPERATION F1 EL 10 6 2 SETTING AUTO OFF F2 OFF 11 6 3 SETTING THE PRINTING CONTROLS F3 SEr 11 6 4 PRINTING DETAIL CONT...

Page 3: ...nstructions as below 1 Remove the base and pillar sections from the packaging 2 Lift the lower pillar section and place it with the screw holes at the rear onto the back of the base allowing for the c...

Page 4: ...Do not use near large users of electricity such as welding equipment or large motors Do not let the balance battery go flat If you are not using it for a long time you should charge the battery perio...

Page 5: ...D DISPLAY FUNCTION The keypad and display have a number of features as shown and explained below Charging LED Battery Symbol Zero Indicator Stable Indicator Tare Symbol Ultrasonic Sensor Symbol All ma...

Page 6: ...rging indicator in the lower left corner of the LCD will be on to show it is charging and will turn green when the battery is fully charged KEYS PRIMARY FUNCTION SECONDARY FUNCTION To turn the scale O...

Page 7: ...e parameters section 6 0 5 2 ZEROING You can press the Zero key to set a new zero point and show a zero reading This may be necessary if the weight reading is not indicating zero with nothing on the p...

Page 8: ...nified by the symbol in the upper right part of the display and start to determine the height When a stable reading of weight is obtained the three readings will be displayed The results will remain o...

Page 9: ...rint and Clear keys to move the flashing digit and the kg lb and cm ft keys to enter the Id number you require and press Zero to save The display will now show the Patients Id screen use the keys as a...

Page 10: ...T T T See section 6 7 Setting the date and time F8 F8 F8 F8 SET SET SET SET UP UP UP UP See section 6 8 Set up parameters F9 F9 F9 F9 TE TE TE TECH CH CH CH Service only 6 1 SETTING THE BACKLIGHT OPER...

Page 11: ...PRINTING CONTROLS F F F F3 3 3 3 SE SE SE SER R R R The MUW can be set to automatically print AUTO or print on demand PrN by pressing the Print button The data transmission speed Bps of the MUW must...

Page 12: ...s can all be enabled or disabled to suit the information you need to see 1 Switch on the scale then press the kg lb key during the self checking test of the display 2 The display will show the first f...

Page 13: ...plete the display will show AdJUST XX If after calibration the height sensor is not measuring correctly press Print or Clear at point 3 to change XX A lower number will decrease the height measurement...

Page 14: ...her the Print or Clear key to move the flashing digit to the left or right 8 Press Zero to save cm ft to exit then kg lb to select the next parameter 6 8 SET UP F8 F8 F8 F8 SET SET SET SET UP UP UP UP...

Page 15: ...w kg or lb press Print to select the unit of weight being used for the calibration and then Zero to confirm 3 The display will show CAL XX XX being the last calibration weight to be used 4 Press the P...

Page 16: ...be sent in upper case letters i e T not t Z cr lf Will Zero the scale performs the same functions as pressing the Zero key P cr lf Will send a Print command to a PC or Printer Performs the same funct...

Page 17: ...too high Err L Calibration weight value used too low Weight on top pan exceeds 300kg 660Lbs 10 0 TECHNICAL SPECIFICATIONS Model MUW 300L Maximum Capacity 300kg 660Lbs Readability 0 05kg 0 1Lbs Repeat...

Page 18: ...orrect documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accid...

Page 19: ...likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure...

Page 20: ...s Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this public...

Reviews: