background image

P a g e

9                 

© Adam Equipment Company 2013

 

3.0  RS-232 SPECIFICATION 

T

he  GK  indicator  and  GBK/GFK  scale  are  both  supplied  with  bi-directional  RS-232  interface  as  standard. 

The  indicator  when  connected  to  a  printer  or  computer  outputs  the  weight  with  the  selected  weighing  unit 
through the RS-232 interface. 

 Default Specifications: 

 

 

 

 

 

 

 

Connector: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232 output of weighing data 

ASCII code 

9600 Baud (user selectable) 

8 data bits 

No Parity 

9 pin d-sub miniature socket 

 

Pin 3  Output 

 

Pin 2  Input 

 

Pin 5  Signal Ground 

Summary of Contents for GBK 120

Page 1: ...ecycled materials and environmentally friendly packaging where possible As part of this initiative we have developed a short manual that uses less paper and ink to describe the main functions of your new Adam indicator scale A complete version is available at www adamequipment com Thank you for your support of Adam Equipment and we hope that you enjoy your new scale ...

Page 2: ... Adam Equipment Company 2013 ...

Page 3: ... 2 2 TARING 3 2 3 PARTS COUNTING 4 2 4 CHECK WEIGHING 5 2 5 PERCENT WEIGHING 6 2 6 ANIMAL Dynamic WEIGHING 7 2 7 ACCUMULATED TOTAL 8 3 0 RS 232 SPECIFICATION 9 4 0 CALIBRATION 10 4 1 CALIBRATION COUNTER FOR APPROVED SCALES 10 5 0 SPECIFICATIONS 11 6 0 ERROR MESSAGES 16 7 0 MENU STRUCTURE 17 8 0 WARRANTY INFORMATION 18 ...

Page 4: ...P a g e 2 Adam Equipment Company 2013 ...

Page 5: ...ght disabled the life is approximately 70 hours before needing to be recharged The battery should be charged for 12 hours for full capacity 2 0 OPERATION 2 1 ZEROING You can press the Zero key at any time to set the zero point from which all other weighing and counting is measured The scales have an automatic re zeroing function to account for minor drifting or accumulation of material on a connec...

Page 6: ...tering parts counting and press Tare Press Cnt to enter the Parts Counting mode The display will show the last sample size used For example 10 Pcs To change the sample size you can press CE to clear the last values and then enter the value 20 using the numeric keypad Place the right number of parts on the platform Then press Cnt to determine an average piece weight After the sample has been weighe...

Page 7: ... value will return the scale to weighing with the Check weighing function enabled During parts counting and percent weighing the limits are set in the same way as above The limits are displayed in pcs or To disable the check weighing function enter zero into both the limits as described above When the current limits are shown press CE to clear the settings then press Tare to store the zero values ...

Page 8: ...ey F4 PCt will be displayed Press Tare again to enter percent weighing The scale will set the sample mass on the platform as 100 reference weight NOTE If there is no reference weight on the pan and percent weighing function is entered pressing Tare again will return the indicator to normal weighing Remove the sample weight Then any other weight placed on the platform will be displayed as a percent...

Page 9: ...ll show Filt x where x is a value from 1 to 5 To increment the value shown press the Func key then press the Tare key to accept it The display will flash Ani 2 times then show the current weight 0 00 The scale is now ready to weigh Place containers or blankets onto the platform and press the Tare key to zero the display Place the animal to be weighed on the platform When a stable reading is found ...

Page 10: ... 2 for 2 seconds and then show the new total Continue until all weights have been added This can continue for up to 99 entries until the capacity of display is exceeded To view the total in memory press the Print key when the indicator is at zero The display will show the total number of accumulation ACC xx and the total weight before returning to zero To print the total press Print to recall and ...

Page 11: ...rface as standard The indicator when connected to a printer or computer outputs the weight with the selected weighing unit through the RS 232 interface Default Specifications Connector RS 232 output of weighing data ASCII code 9600 Baud user selectable 8 data bits No Parity 9 pin d sub miniature socket Pin 3 Output Pin 2 Input Pin 5 Signal Ground ...

Page 12: ...rn to normal weighing if entered directly Remove the calibration mass If an error message FAIL H or FAIL L is shown re check the calibration and repeat If the error cannot be corrected contact your supplier 4 1 CALIBRATION COUNTER FOR APPROVED SCALES The approved GK M GBK M GK M Models scales have the ability to control access to the calibration or metrology parameters using a passcode to limit ac...

Page 13: ...rating Temperature 10 C 40 C 14 F 104 F Power supply 230 VAC 50 60 Hz 12V 800ma adaptor for USA versions Battery Internal rechargeable battery Calibration Automatic External Display 6 digits LCD digital displays with capacity tracker and symbols for units Indicator Housing ABS Plastic Overall Dimensions wxdxh 260 x 170 x 115mm 10 2 x 6 7 x 4 5 Net Weight 1 8 kg 4 lb Applications Weighing and check...

Page 14: ...for USA Calibration External Calibration Mass User Selectable Display Backlit Green display 20mm with capacity tracker Balance Housing Cast aluminum base Pantone cool grey painted base stainless steel grade 304 Top pan ABS Cool grey indicator housing Pan Size 400mm x 500mm x 65mm 15 7 x 19 7 x 2 6 400mm x 500mm x 65mm 15 7 x 19 7 x 2 6 400mm x 500mm x 65mm 15 7 x 19 7 x 2 6 600mm x 800mm x 65mm 23...

Page 15: ...a only XXXa also to have pounds Ounces Pound Ounces Stabilization Time 2 3 Secs Operating Temperature 10 C to 40 C 14 F to 104 F Power Supply 230VAC 50 60Hz in Europe Asia and South Africa 12vDC 800mA UL CSA adapter for USA Calibration External Calibration Mass User Selectable Display Backlit Green display 20mm with capacity tracker Balance Housing Cast aluminum base Pantone cool grey painted base...

Page 16: ...0VAC 50 60Hz Calibration External Calibration Mass User Selectable Display Backlit Green display 25mm with capacity tracker Balance Housing Cast Aluminum base Pantone cool grey painted base stainless steel grade 304 Top pan ABS Cool grey indicator housing Pan Size 400mm x 500mm 15 7 x 19 7 Overal Dimensions w x d x h 400 mm x 620 mm x 860 mm 15 7 x 24 4 x 33 9 Net Weight 12 5kg 27 6 Lb Features We...

Page 17: ...F Power Supply 230VAC 50 60Hz Calibration External Calibration Mass User Selectable Display Backlit Green display 25mm with capacity tracker Balance Housing Cast Aluminum base Pantone cool grey painted base stainless steel grade 304 Top pan ABS Cool grey indicator housing Pan Size 300mm x 400mm x 50mm 11 8 x 15 5 x 2 Overal Dimensions w x d x h 300mmx 520mm x 660mm 11 8 x 20 5 x 26 Net Weight 7 6k...

Page 18: ...t on the platform when turning the indicator on Excessive weight on the platform when zeroing the indicator Platform is not installed Improper calibration of the indicator Damaged load cell Damaged Electronics Err 6 A D count is not correct when turning the indicator on Load cell is damaged Electronics is damaged Err 7 Percent input error Percent function is entered with no reference mass on the p...

Page 19: ... Prt on Prt oFF C2 bd Baud Rate 600 To 19200 C3 Prm Printing Mode mA StA Manual Stable mA AnY Manual Any Au StA Auto Stable Au End Auto End Ct StA continuous Stable Ct AnY Continuous Any C4 Aon Enable Accumulation on oFF C5 Ln Language for printing English French German Spanish C6 Uid User ID Enter using numeric keys C7 Sid Scale ID Enter using numeric keys C8 LAb LAb On Lab Off FUNC 3 Scale Param...

Page 20: ...ginal packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requiremen...

Page 21: ...19 P a g e Adam Equipment Company 2013 ...

Page 22: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CALI...

Page 23: ...Phone 49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail vertrieb aeadam de Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11 974 9745 Fax 27 0 11 392 2587 e mail sales adamequipment co za Adam Equipment S E ASIA PTY Ltd 2 71 Tacoma Circuit CANNING VALE 6155 Perth Western Australia Phone 61 0 8 6461 6236 Fax 61 0 8 9456 4462 e m...