background image

 

© Adam Equipment Company 2006 

 

24

 
 
 
 

WARRANTY INFORMATION 

 
 

Adam Equipment offers Limited Warranty (Parts and Labour) for the 
components failed due to defects in materials or workmanship.  Warranty 
starts from the date of delivery. 
 
During the warranty period, should any repairs be necessary, the 
purchaser must inform its supplier or Adam Equipment Company. The 
company or its authorised Technician reserves the right to repair or 
replace the components at the purchaser’s site or any of its workshops 
depending on the severity of the problems at no additional cost. 
However, any freight involved in sending the faulty units or parts to the 
service centre should be borne by the purchaser. 
 
The warranty will cease to operate if the equipment is not returned in the 
original packaging and with correct documentation for a claim to be 
processed. All claims are at the sole discretion of Adam Equipment. 
 
This warranty does not cover equipment where defects or poor 
performance is due to misuse, accidental damage, exposure to 
radioactive or corrosive materials, negligence, faulty installation, 
unauthorised modifications or attempted repair or failure to observe the 
requirements and recommendations as given in this User Manual. 
        
Repairs carried out under the warranty does not extend the warranty 
period. Components removed during the warranty repairs become the 
company property. 
        
The statutory right of the purchaser is not affected by this warranty. The 
terms of this warranty is governed by the UK law. For complete details on 
Warranty Information, see the terms and conditions of sale available on 
our web-site. 

 
 
 
 
 

Summary of Contents for CBW 15

Page 1: ...SERIES P N 4276 Rev B8 November 2006 Software rev 1 2 2 04 For CBW 6H rev 1 4 3 00 Inscale Measurement Technology Ltd 2007 Inscale Measurement Technology www inscale scales co uk www inscale scales co...

Page 2: ...Adam Equipment Company 2006...

Page 3: ...ing while Parts Counting 12 6 7 ACCUMULATED TOTAL 12 6 8 MANUAL ACCUMULATION 13 6 9 AUTOMATIC ACCUMULATION 14 7 0 PARAMETERS 14 7 1 INCREMENT VALUE 15 7 2 CONTROL THE BACKLIGHT 15 7 3 AUTOMATIC ACCUMU...

Page 4: ...Adam Equipment Company 2006 2...

Page 5: ...BS base assembly All scales have sealed keypads with colour coded membrane switches and the displays are large easy to read liquid crystal type displays LCD The LCD s are supplied with a backlight The...

Page 6: ...of measure Kg g Interface RS 232 bi directional Interface Optional Stabilisation Time 2 Seconds typical Operating Temperature 0 C 40 C Power supply 9 VDC 800 mA Through an external adapter Battery Int...

Page 7: ...nsation Avoid direct contact with water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not place near open windows or air conditioning vents Keep...

Page 8: ...n number A self test is followed next At the end of the self test it will display ZERO if the zero condition has been achieved A stable symbol and GROSS indicators are also displayed 4 0 KEY DESCRIPTI...

Page 9: ...is not in the weighing mode it will return the user to weighing A secondary function C is available to act as a clear key when setting values for parameters or other functions Print It is used to prin...

Page 10: ...ther weighing and counting is measured This will usually be necessary when the platform is empty When the zero point is obtained the display will show the indicator for ZERO The scale has an automatic...

Page 11: ...ack to the same condition it was when Zero Enter was last pressed 6 3 WEIGHING A SAMPLE To determine the weight of a sample first tare an empty container if used then place the sample in the container...

Page 12: ...nting i e 10 20 50 100 or 200 pieces Press the Zero Enter key when the number matches the number of parts used for the sample As more weight is added the display will show the number of parts pcs Pres...

Page 13: ...weighing with the Check weighing function enabled When a weight is placed on the scale the arrows will show whether the weight is above or below the limits and the beeper will sound as described belo...

Page 14: ...ck weighing to operate To disable the Checkweighing function enter zero into both limits by pressing Limit to recall the current settings When the current limits are shown press Func C to clear the se...

Page 15: ...ill be output to a printer or PC Remove the weight allowing the scale to return to zero and put a second weight on Press Print the display will show ACC 2 and then show the new total Continue until al...

Page 16: ...d In all cases the scale must return to zero or a negative number before another sample can be added to the memory More products can be added and Print be pressed again This can continue for up to 99...

Page 17: ...ally i e turning it off when the scale is not being used The backlight can be set to be EL on always on EL AU Automatic or EL oFF always off The maximum battery life is achieved with the backlight tur...

Page 18: ...weight is almost near zero This helps to make sure that the scale is measuring weight from an accurate zero starting point The Auto zero value can be set to 0 5 1 2 or 4 scale divisions The normal se...

Page 19: ...when check weighing 1 will set the buzzer to on when the OK symbol is on 2 will set the buzzer to on when the weight is outside the OK symbol limit To change this digit press the Tare key Press the Z...

Page 20: ...the scale and plug in The scale does not need to be turned on The battery should be charged for 12 hours for full capacity To the left of the display is a LED to indicate the status of battery chargi...

Page 21: ...niature socket Pin 3 Output Pin 2 Input Pin 5 Signal Ground Data Format Normal Output GS 1 234 Kg GS for Gross weight NT for net weight with tare value stored U W 123 g Kg and g for metric and Lb for...

Page 22: ...DS FORMAT The scale can be controlled with the following commands The commands must be sent in upper case letters i e T not t Press the Enter key of the PC after each command T cr lf Tares the scale t...

Page 23: ...tion mass on the pan It is best to use a weight close to the full capacity of the scale Press the Zero Enter key The display will then show the last mass used If this is same as the mass on the pan th...

Page 24: ...tion of the scale Damaged load cell Damaged Electronics Err 5 Keyboard error Improper operation of the scale Err 6 A D count is not correct when turning the scale on Platform is not installed Load cel...

Page 25: ...y A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be avail...

Page 26: ...ease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warra...

Page 27: ...tion against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accord...

Page 28: ...W UK Phone 44 0 1908 274545 Fax 44 0 1908 641339 e mail sales adamequipment co uk Adam Equipment Inc 26 Commerce Drive Danbury CT 06810 USA Phone 1 203 790 4774 Fax 1 203 792 3406 e mail sales adamequ...

Reviews: