Adam Equipment AE 504 Series User Manual Download Page 25

 

© Adam Equipment Company 2019 

 

 

 

 

 

 

 

24

 

NOTE: if the text for the barcode is entered incorrectly then an error message  will 
appear indicating a wrong entry.  

 

 

 

9.1.7 

Adding QR Codes 

 

  Left click the QR code icon located in the editing tools section and click on the label 

area to place the QR code picture. The parameters for the QR code are as follows: 

 

 

 

9.1.8 Deleting 

items 

 

 

  Select the item you want to delete by left clicking it and press the delete button on 

the keypad.  

 

 

  A  message  will  appear  asking  the  user  to  confirm  the  deletion.  Press 

‘OK’

  to 

confirm and the item will then be deleted from the label.  

X: 

8=1mm, 400=50mm 

Y: 

8=1mm, 400=50mm

 

Thickness: 

The size of the QR code will affect the size of the 

QR code. The bigger in size, the easier to scan 

Error Correction Level: 

The bigger the percentage, the 

easier it is to recover lost print data 

Text: 

The text entered can be a web link or common words 

so when the QR code is scanned with a smart device it will 
take the user to the address entered in this parameter.  

Summary of Contents for AE 504 Series

Page 1: ...Adam Equipment Company 2019 Adam Equipment AE 504 Software rev V 1 00 above...

Page 2: ...uipment Company 2019 Easy Reference Model name of the indicator scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier a...

Page 3: ...mulation Totalising 13 6 5 SETTING THE PLU DATA 14 6 5 1 Edit the PLU data 14 6 5 2 Input letter 15 6 5 3 Setting by PC recommend 15 7 0 USER PARAMETERS 17 8 0 CALIBRATION 19 8 1 SIMPLE CALIBRATION 19...

Page 4: ...et to verify counts up to 60000 divisions All indicators are supplied with a RS 232 bi directional interface and real time clock RTC The indicator has a sealed keypad with colour coded membrane switch...

Page 5: ...o Range 0 10mv Signal range 20mV 20mV A D conversion method DIGITAL SECTION Capacity 1 800000kg Verified counts 1 30000 1 60000 A D conversion speed 8 times sec Max A D conversion bits 24 Operating Te...

Page 6: ...r 80mm Functions Parts counting weighing percentage weighing checkweighing pre set count with alarm Interface RS 232 bi directional interface English German French Spanish selectable text Date Time Re...

Page 7: ...temperature Do not place in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large u...

Page 8: ...hown below The cable length should be as short as possible using a large size wire to minimise errors due to resistance in the leads 3 3 1 Fixing the cable and the indicator Thread the cable through t...

Page 9: ...the preinstall value M Add all the quantities and store the max Total Number of Additions is 99 AVG On Off the automatic average function QTY PST Preinstall the High low Limit values ID Press this key...

Page 10: ...the net weight Entering a value using the keypad will store that as the tare value 0 Zero Sets the zero point for all subsequent weighing to show zero 5 0 DISPLAYS The indicator includes one LED displ...

Page 11: ...h even though the piece weight is too small however this may affect the count accuracy Press Q TY PST key to enter the H L Limit value for Quantity Preset in the weighing mode LIMOF is used to configu...

Page 12: ...the same condition as it was when the Zero 0 key was pressed last 6 2 1 Preset tare When the scale platform is empty press the Tare key on the indicator the display will now show Pre tare Enter the w...

Page 13: ...ow see LIMOF then Weight or Count on the display press the M key in order to alternate between the two Once selected press the Q TY PST key to move to the next setting CHLn0d H L should now appear on...

Page 14: ...he larger the sample weight is the more accurate the quantity will be With both the Unit weight and Quantity displays showing zero pressing either the UNIT W T Key or the SMPL key will recall the late...

Page 15: ...ed 6 5 SETTING THE PLU DATA In pricing computing mode use number keypad to input PLU serial number then press PLU can get the weights name and unit weight of the corresponding weights The display will...

Page 16: ...blink press once again the display will show B and so on After the letter stops flashing it means this letter has been inputted To return to number input mode press ABC the letter input sign will als...

Page 17: ...ort Click if this succeeds this will show Success The user can then set the next PLU DOWNLOAD MULTIPLE PLU BY TABLE RECOMMEND Use table edit software such as Excel WPS Numbers to new built a file then...

Page 18: ...ey will enter the sub parameter setting Alternatively the user can press the number key that links to a corresponding sub parameter setting For example in T1 FC press 3 the display will jump to T3 bps...

Page 19: ...ep time of the backlight in seconds 1 45 seconds F2 ARG For setting the average unit weight function automatically ON OFF F3 CST Tare and zero stable waiting time ON OFF F4 MAE Turn ON OFF next add up...

Page 20: ...tly NOTE AE504 indicators will have the lb or kg indicator on to show the unit of the weight requested If the scale was in pounds before starting the calibration the weights requested will be in pound...

Page 21: ...software interface 9 1 2 Operation method 1 Connect the indicator to the PC using the RS 232 cable provided this is so the customised label can be downloaded straight to the indicator after completion...

Page 22: ...eters have been set the label can be customised and edited to the desired preference From here select to start a new label design open a previously saved template or save a template to your PC Printer...

Page 23: ...all icon before uploading the image file via the parameter settings section Left click the TEXT icon and the drop down will appear Left click on any variable to add to the label For example net weight...

Page 24: ...tomisable parameters Height The height of the barcode Thickness Minimum line width Barcode type Type of barcode food retailers usually use EAN13 Readable Enable or Disable the Print out of the text be...

Page 25: ...left clicking it and press the delete button on the keypad A message will appear asking the user to confirm the deletion Press OK to confirm and the item will then be deleted from the label X 8 1mm 4...

Page 26: ...software Export the image by selecting the export icon from the barcode icon in the top left hand corner Press the download icon Select the necessary serial port and baud rate and click download 10 0...

Page 27: ...Print 9 pin D subminiature socket Pin 3 Output Pin 2 Input Pin 5 Signal Ground lf cr lf cr ID QTY 0 pcs U W 123 g Kg or g for metric weights and lb for pounds G W 1 234 Kg Net Wt if net weight is disp...

Page 28: ...k Piezas Number of weighings added to subtotals No Nb Anzhl Num Total weight and count printed Total Total Gesamt Total Print date Date Date Datum Fecha Print time Time Heure Zeit Hora 10 1 INPUT COMM...

Page 29: ...ress ID to escape and return to normal weighing mode 10 3 AUTO SLEEP FUNCTION To set the auto sleep function you will need to enter the Other function parameter setting in the User parameters see sect...

Page 30: ...e recommend that you do not always connect to the power supply 11 3 BACKLIGHT FOR LCD The backlight of the LCD can be set to be 1 ON at all the time 2 ON only when a weight is placed on the scale or 3...

Page 31: ...s still shown contact your dealer for further support ERROR CODE DESCRIPTION Solution ADO Over A D resolution range Remove the weights of the pan or send back to the agent ADL Over A D resolution rang...

Page 32: ...4 0 15289 battery 6V10AH 3 10 2 3 15290 printer head roll 3 10 2 0 15291 display panel 3 10 2 3 15292 top houseing 3 10 2 3 15293 base housing 3 10 2 3 15296 printer roller 3 10 2 3 15297 printer hea...

Page 33: ...hods B Details of the unit purchased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a pr...

Page 34: ...ce faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable ba...

Page 35: ...mmercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radi...

Page 36: ...one 49 0 4340 40300 0 Fax 49 0 4340 40300 20 e mail sales adamequipment co za Adam Equipment S A Pty Ltd 7 Megawatt Road Spartan EXT 22 Kempton Park Johannesburg Republic of South Africa Phone 27 0 11...

Reviews: