3.3. CONNECTION FIBRE-OPTIC BUS

The multimode Fibre-Optic with connectors type: ST®, SC or SMA, connect into their corresponding converter's connectors type: ST®,

SC or SMA like on the Fig. 6. Connecting the fiber optic cables should be cautious and careful not to damage them or dirty. If it is

necessary to lay the cable at an angle, must be created the appropriate bends.

ATTENTION!!! 
The device is equipped in the laser transmitter.
The radiation emitted by the laser transmitter is harmful to the eyes! 
Under no circumstances should never look to at the uncovered slot, to which it is not connected the fiber optic 
connector.

3.3.1. WIRING TOPOLOGY FIBER OPTIC BUS

Fig.6. Examples of fiber optic bus connection.

7

ADA-7240

RS-232

ADA-7010

closing

ADA-7240

Multidrop

RS-232

RS-422/485

Current loop

Controller 1

Controller 3

RS-232

PC

Fiber Optic bus

2 fibres 50/125um or 62.5/125

Controller 2

PC

ADA-7210

Multidrop

ADA-7220

Multidrop

ADA-7010

closing

Summary of Contents for ADA-7240

Page 1: ...User manual ADA 7240 RS 485 RS 422 to Multidrop Fiber Optic Converter 1 ADA 7240 Copyright 2001 2017 CEL MAR sp j io_ada 7240_en_v3 22...

Page 2: ...RS422 BUS 5 3 2 1 CONNECTION TO 4 WIRE RS422 BUS 5 3 2 2 CONNECTION TO 4 WIRE RS485 BUS 6 3 2 3 CONNECTION TO 2 WIRE RS485 BUS 6 3 2 4 LINE TERMINATION Rt ON RS485 RS422 BUS 6 3 3 CONNECTION FIBRE OP...

Page 3: ...sable from the supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit...

Page 4: ...isolation between connected devices and resistance to interference on the transmission bus Fiber optic connection is made by the use of two fibres ADA 7240 can be use also for extend the fiber optic b...

Page 5: ...talled within a single object not supply converter from power circuit device that generates large impulse interference such as transmitters contactors 3 1 ASSEMBLING The ADA 7240 converter case is ada...

Page 6: ...not needed below 9600Bd should be used the Line Termination resistor if the distance is over 1000m 9600Bd or 700m 19200Bd transmission Example connection of Rt are shown on Fig 3 4 5 Two resistors Rt...

Page 7: ...NTION The device is equipped in the laser transmitter The radiation emitted by the laser transmitter is harmful to the eyes Under no circumstances should never look to at the uncovered slot to which i...

Page 8: ...ctor TX RX RX DSR DTR RTS CTS TX V V PC RS232 connector RX DSR DTR RTS CTS TX ADA 7020 Current loop connector FO Conn TX RX V TX TX RX RX V Controller Current loop connector V TX TX RX RX V ADA 7240 R...

Page 9: ...s automatic data flow control 2 wire and 4 wire RS485 network Full duplex or half duplex transmission 4 2 DEFAULT SETTING The ADA 7240 converter is being set in RS485 mode during production as in the...

Page 10: ...and receiver for an optical wavelength from 640nm to 675nm Screw terminal wire max 2 5mm2 Line length up to 2000m for fibre type 50 125 mm up to 2500m for fibre type 62 5 125 mm up to 2000m for fibre...

Page 11: ...onmental Parameters Operating temperature Standard version S 0 C 23 C 50 C Extended version E 30 C 23 C 60 C Humidity 5 95 non condensing Storage temperature 40 70 C Casing Dimensions 71 x 90 x 58 mm...

Page 12: ...transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you p...

Reviews: