background image

WARRANTY DOESN’T EXTEND TO FOLLOWING CASES:

1. If the standard or serial product number will be changed, erased, removed or wil be unreadable.

2. Periodic maintenance, repair or changing parts as a result of their normal runout.

3. All adaptations and modiications with the purpose of improvement and expansion of normal sphere of product ap-

plication, mentioned in the service instruction, without tentative written agreement of the expert provider.

4. Service by anyone other than an authorized service center.

5. Damage to products or parts caused by misuse, including, without limitation, misapplication or nrgligence of the terms 

of service instruction.

6. Power supply units, chargers, accessories, wearing parts.

7. Products, damaged from mishandling, faulty adjustment, maintenance with low-quality and non-standard materials, 

presence of any liquids and foreign objects inside the product.

8. Acts of God and/or actions of third persons.

9. In case of unwarranted repair till the end of warranty period because of damages during the operation of the product, 

it’s transportation and storing, warranty doesn’t resume.

Summary of Contents for ZHT 100

Page 1: ...ADA ZHT 100 00109 http www vseinstrumenti ru instrument izmeritelnyj gigrometry ada zht_100_a00109 http www vseinstrumenti ru instrument izmeritelnyj gigrometry ada zht_100_a00109 tab Responses...

Page 2: ...ZHT 100 ZHT 100 ADAINSTRUMENTS WWW ADAINSTRUMENTS COM...

Page 3: ...ZHT 100 1 3 2 3 3 3 4 4 5 6 6 7 7 7 8 7 9 8 10 8 11 1 12 2...

Page 4: ...ZHT 100 MEASUREMENT FOUNDATION ZHT 100 9 ZHT 100 2 1 RH 10 90 25 30 100 0 80 0 01 RH 0 01...

Page 5: ...MEASUREMENT FOUNDATION 10 90 25 2 5 OL 0 40 80 10 60 80 15 9 ZHT 100...

Page 6: ...MEASUREMENT FOUNDATION 225 45 34 200 ZHT 100 0 100 30 100 0 01 2 25 20 80 0 5 0 9 25 0 8 1 5 0 100 80 20...

Page 7: ...ZHT 100 MEASUREMENT FOUNDATION 1 2 C F BAT MAX MIN 3 MAX MIN MAX MIN MAX MIN 2 4 C WBT Due point C WBT Due point 5 6...

Page 8: ...ZHT 100 MEASUREMENT FOUNDATION 2 7...

Page 9: ...MEASUREMENT FOUNDATION 1 ZHT 100...

Page 10: ...___________________________ _____________________________________________________________________________ _______________ ______________________________________________________________________________...

Page 11: ..._______________________________________________ ___________________ _________________ ___________________ 12 II 454 491 _________________________________...

Page 12: ...1 2 3 4 5 6 7 8 9 WWW ADAINSTRUMENTS COM info adainstruments com...

Page 13: ...Operating manual Humidity and Temperature meter Model ZHT 100 Manufacturer Address WWW ADAINSTRUMENTS COM...

Page 14: ...3 Functionality 14 4 Speciications 15 5 Features 17 6 Humidity and air temperature measurements 18 7 Safety instructions 18 8 Battery replacement 18 9 Warranty 19 10 Exceptions from responsibility 19...

Page 15: ...ractical applications for professional and home use The Humidity Temperature Meter has semiconductor sensor Microprocessor processes data This operations manual contains general information and specii...

Page 16: ...10S 90 at 25 C still air Sampling Rate 2 5 samples per second Polarity Automatic negative polarity indication Over range OL mark indication Operating Conditions 0 to 40 C 80 RH non condensing Storage...

Page 17: ...dity 0 100 RH Temperature 30 C 100 C Resolution 0 01 RH Humidity Accuracy 2 RH at 25 C 20 80 RH 2 5 RH at other ranges Air Temperature Accuracy 0 5 C 0 9 C at 25 C 0 8 C 1 5 C all other ranges Note Th...

Page 18: ...re that the MAX MIN reading will not exceed the testing range Press once to select MIN Press again to select MAX Press and hold the Button for over 2 seconds to turn off MAX MIN Recording 4 C Dew Poin...

Page 19: ...Relative Humidity and Air Temperature dew point temperature wet bulb temperature Safety instructions Do not immerse the probe in liquid it is intended for use in air only Don t expose the sensor to d...

Page 20: ...r warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product s accuracy and general performance The manufacturer or its representatives assumes no r...

Page 21: ...__________________ _____________ name and model of the instrument Corresponds to ______________________________________________________________ designation of standard and technical requirements Data...

Page 22: ...r fault identiication which is under the warranty is made only in the authorized service center In no event shall manufacturer be liable before the client for direct or consewuential damages loss of p...

Page 23: ...ice by anyone other than an authorized service center 5 Damage to products or parts caused by misuse including without limitation misapplication or nrgligence of the terms of service instruction 6 Pow...

Page 24: ......

Page 25: ...ADA MEASUREMENT FOUNDATION WWW ADAINSTRUMENTS COM...

Reviews: