6D
MAXLINER
MEASUREMENT FOUNDATION
To check level
Choose a wall and set laser 5M away from the wall. Turn on the laser and cross laser line is marked A on the wall. Find another
point M on the horizontal line, the distance is around 2.5m. Swivel the laser, and another cross point of cross laser line is marked B.
Please note the distance of B to A should be 5m.
Measure the distance between M to cross laser lune, if the difference is over 3mm, the laser is out of calibration, please contact with
seller to calibrate the laser.
28