1.  Product  Introduction

    Wattman  (HPM-100A)isaconsumption/standby  power  analyzer  and  a  practical  and  economical  handheld-type  wattmeter.  It 

enables  the  measurement  of  the  power  consumption  of  home  appliances  and  business  equipment  with  not  greater  than  a 

9mW~3.75kW  power  consumption,  in  a  Plug  &  Play  way,  thus  allowing  easy  and  simple  operation  by  any  user.  It  also 

enables  the  easy  conversion  of  electric  power  usage  data  into  electric  charge  and  amount  of  CO2  emission  values.

⊙ 

Characteristics

    -  It  displays  the  voltage,  current,  power,  and  frequency  at  the  same  time.  It  can  also  display  the  power  factor,                   

        electric  energy,  electric  charge,  and  amount  of  CO2  emission  based  on  the  amount  of  electric  energy  used.

    -  There  is  no  need  for  batteries  and  adaptors  as  no  additional  power  operation  is  needed.

    -  Superior  precision,  with  a  base  error  range  of  ±0.4%.

    -  Equipped  with  universal  and  convenient  multiplug  sockets.

    -  Its  front  buttons  enable  the  selection  of  the  unit  to  be  used  for  the  electric  charge  and  the  amount  of  CO2  emission.

    -  Equipped  with  a  time  setting  function  (00.hr:  unlimited;  1~24  hr).

    -  Comes  with  a  free  copy  of  the  GUI  PC  program.

    -  With  free  portable  bags.

    -  Cable  supply  for  data  communication  use  (with  charge).

       

    Warning 

    -  Extreme  caution  against  high  voltage  should  be  taken  whenusingthisproduct.

    -  The  inappropriate  use  of  this  product  may  cause  casualties  or  electric  shock.

    -  Observe  all  the  safety  guidelines  stated  in  the  accompanying  manual.

    -  Do  not  repair  your  own  unit  unless  you  have  the  necessary  skills. 

⊙ 

Safety  Instructions

    This  equipment  was  designed  in  accordance  with  the  CE  CAT  II  &  FCC  safety  standards.  The  users,  however,  must       

    have  a  thorough  knowledge  of  the  following  guidelines  and  must  use  the  product  with  full  attention  to  ensure  safe           

    operation.

        -  Do  not  attempt  to  operate  the  product  if  you  cannot  close  its  back  cover.

Summary of Contents for Wattman HPM-100A

Page 1: ... 1 Consumption Standby Power Meter Manual Product Name Wattman HPM 100A AD Power Co Ltd ...

Page 2: ... 2 CONTENTS 1 Product Introduction 3 2 Power Measurement 7 3 Electric Energy Measurement 7 4 PC Communication Method 9 5 Functions of Hold and the Backlight 10 6 Others 10 ...

Page 3: ...s needed Superior precision with a base error range of 0 4 Equipped with universal and convenient multiplug sockets Its front buttons enable the selection of the unit to be used for the electric charge and the amount of CO2 emission Equipped with a time setting function 00 hr unlimited 1 24 hr Comes with a free copy of the GUI PC program With free portable bags Cable supply for data communication ...

Page 4: ...l General Characteristics It is easy to analyze the voltage electric current and frequency values obtained as they are displayed at the same time 0 4 electric power accuracy 0 3 voltage and electric current accuracy Voltage measurement range AC 90 260V 0 3 3 digit Electric current measurement range AC 100μA 15A 0 3 3 digit Electric power measurement range 9mW 3 75kW 0 4 3 digit Power factor measur...

Page 5: ... a new measurement DISPLAY Voltage W accumulative electric energy Wh power factor PF amount of CO2 emission kg and electric charge mode conversion button W h TIM E SET Time setting for electric energy Wh accumulation 00 hr unlimited 1 24 hr W h RUN STO P Start stop accumulation setting in the accumulative electric energy mode At the start of the accumulation ENERGY will be displayed on the LCD scr...

Page 6: ...Euro European currency unit For European Union member s use 9 Yuan Chinese currency unit For Chinese s use 10 Dollar U S currency unit For American s use 11 Won Korean currency unit For Korean s use 12 Power Factor Displays the power factor of the equipment to be measured 13 Electric Power Displays the electric power consumption of the equipment to be measured 14 Electric Energy per hour Displays ...

Page 7: ...ment Electric energy measurement will be conducted up to 2000 kWh Ex For the instantaneous power of 1 KW it is 2000 hours 1 DISPLAY Press the button to set the accumulative electric energy mode 2 Press the W h TIM E SET and buttons to set the desired accumulation time 1 24 hr If the time does not change Wh CLR reset after the initialization 3 Press the W h RUN STOP button and ENERGY will be displa...

Page 8: ...untperkWhappliedcanbemodified ifnecessary Electric Charge Measurement Please note that the average electric charge of an average household with an electric power usage rate of 300 kWh month is KRW168 kWh Ex Electric charge KRW 1 kWh 168 The electric charge unit can be modified using the Setting key CO2 Emission Amount Measurement The allowable amount of fossil fuel petroleum coal CO2 emission for ...

Page 9: ...r Micom or when RS 232 is pressed data will be consecutively received and COMM will be displayed on the product s screen When the English capital letter E is transmitted the communication will be cancelled S on the communication screen means the start of a set of data while E means the end Warning When collecting data through the HPM 100A GUI program the accumulated Wh value on HPM 100A will be re...

Page 10: ...til HOLD is pressed again To operate the LCD backlight press LIGHT The power consumption of the backlight is not included in the measured value 6 Others Maintenance Warning To prevent electric shock or damage take note of the following 1 Do not separate the equipment from its case when the power source is applied 2 Use an identical voltage rating 250V 15A when replacing a fuse damaged due to overl...

Page 11: ... s negligence or due to a natural disaster extra charges will be applied for the services rendered by the company s A S service team 4 It is much safer to have the product repaired by the company s service personnel even beyond the warranty period A S Service Center Contact No 82 32 234 3794 Accessories Manual for users portable bag cable supply for data communication use with charge AD Power Co L...