Before any work on the boiler, it is important to disconnect the
power supply.
It is important to carry out all the electrical connection before
changing the MCBA parameters.
1. The 12kΩ NTC sensor must be inserted into the dywell and connected on
terminals 3 and 4.
[See the picture below].
2. Connect the DHW pump to the dedicated connector on the internal wiring
[see the wiring diagram]
.
domestic hot Water connection
prestige solo + smart tank
- Rinse the installation before connecting the domestic hot water circuit.
- Fill the tank before filling the heating circuit.
optional accessories
code
description
10800079
Domestic hot water hydraulic kit:
Kit to connect a Prestige Solo boiler to an external
water heater.
The kit includes :
- one circulator
- one NTC sensor 12kΩ (L = 3,2 m)
- one check valve
- four copper pipes + gaskets
5476g003
NTC sensor 12kΩ :
Senses the temperature in the external hot water
tank.
(Delivered with the kit 10800079)
1. Cold water supply tap
2. Non-return valve
3. Safety group
4. Pressure reducing valve
5. Hot water expansion vessel
6. Thermostatic mixer
7. Drawoff tap
factury
setting
typical
setting
description
Domestic hot water temperature
setting
(to be adjusted between
60 and 80°C)
.
00
: DHW Mode “OFF”
01
: DHW Mode “ON”
12
: Tank with NTC sensor
13
: Tank with control thermostat