en
12
HRs / Jumbo
: 661Y1200 • C
EN
NL
ES
IT
DE
PL
RU
FR
TECHNICAL CHARACTERISTICS
PERFORMANCE
DHW performance
HRs
HR
s
/JUMBO
Operating conditions at 80°C
321
601
800
1000
Peak flow at 40 °C
L/10'
922
1345
1881
2265
Peak flow at 45 °C
L/10'
790
1153
1612
1941
Peak flow at 60 °C
L/10'
504
706
961
1145
Peak flow at 40 °C
L/60'
2732
3437
4270
4940
Peak flow at 45 °C
L/60'
2342
2946
3660
4234
Peak flow at 60 °C
L/60'
1402
1733
2124
2438
Constant flow at 40 °C
L/h
2172
2511
2868
3210
Constant flow at 45 °C
L/h
1862
2152
2458
2751
Constant flow at 60 °C
L/h
1077
1232
1395
1562
Coefficient
NL
18
34
67
87
Primary heating input power
kW
76
88
100
112
Operating temperature : 90°C
Water supply temperature : 10°C
MAXIMUM OPERATING CONDITIONS
Maximum Service Pressure [tank full of water]
- Primary circuit : ..................................................3 bar
- DHW water circuit : ....................................... 10 bar
Operating Temperature
- Maximum temperature : ................................90°C
Supply Pressure (DHW circuit)
- Max. 6 bar without requiring a pressure reducing valve
Water Quality
- Chlorides < 150 mg/L
- 6 ≤ pH ≤ 8
- If the water hardness is > 20°fH, the installation of a water softener is recommended.