background image

6

TECHNICAL SPECIFICATION

DIMENSIONS

The units are delivered fully assembled, tested and packed on a timber base with shockproof edges and protected by heat-shrunk plastic film.
On reception and after unpacking, check the equipment for damage. For transport purposes, refer to the weight 

(page 5)

and dimensions given

below.

D

G

F

E

J

H

B

A

K

C

D

A

C

C/2

A mm

B mm

C mm

D mm

E mm

F mm

G Ø mm

H mm

J mm

K mm

HM 60 N

1698

1583

538

625

540

390

150

1098

281

1665

HM 60 N BG 2000-S 60

1698

1583

538

801

540

390

150

1098

281

1665

HM 70

1743

1630

678

797

680

390

150

1289

285

1720

HM 70 N BG 2000-S 70

1743

1630

680

937

680

390

150

1289

285

1720

HM 100 N

2093

2030

680

797

680

390

150

1693

285

2120

HM 100 N BG 2000-S 100

2093

2030

680

937

680

390

150

1693

285

2120

HM 150 Jumbo

2124

2117

1020

1440

1020

600

250

1383

590

2250

HeatMaster 60 N

Without burner

With ACV BG 2000-S

premix gas burner

Summary of Contents for HM 60 N

Page 1: ...and Servicing Instructions HM 60 N 70 N 100 N 150 JUMBO HM 60 N 70 N 100 N With ACV BG 2000 S premix gas burner HM 60 N 70 N 100 N With ACV BM 101 oil burner HM 150 JUMBO With ACV BM 151 oil burner He...

Page 2: ...specified by ACV Failure to observe instructions regarding tests and test procedures can result in personal injury or pollution risks Note ACV reserves the right to modify the technical specification...

Page 3: ...in conjunction with HR and Jumbo hot water storage tanks the Heatmaster can supply even the largest hot water requirement Standard equipment The HeatMaster 60 N 70 N 100 N and 150 Jumbo has the follow...

Page 4: ...pump Primary expansion vessel Heating circuit filling valve with removable hose and non return valve Automatic air vent Heating return Burner Tank in Tank heat exchanger Flue pipes and turbulators Flu...

Page 5: ...2 21 20 19 GRASSLIN GRASSLIN I O Manual reset high limit thermostat Burner lockout indicator Combined temperature and pressure gauge Time clock Servicing socket 230 V 50 Hz Control thermostat ON OFF s...

Page 6: ...942 2133 2133 3172 3172 4828 Peak delivery at 45 C L 60 1656 1656 1794 1794 2680 2680 4138 Peak delivery at 60 C L 60 1106 1106 1219 1219 1813 1813 2864 Peak delivery at 70 C L 60 681 681 971 971 1226...

Page 7: ...A C C 2 A mm B mm C mm D mm E mm F mm G mm H mm J mm K mm HM 60 N 1698 1583 538 625 540 390 150 1098 281 1665 HM 60 N BG 2000 S 60 1698 1583 538 801 540 390 150 1098 281 1665 HM 70 1743 1630 678 797...

Page 8: ...7 TECHNICAL SPECIFICATION D G F E J H B K A C D A C C 2 A K H J E C D F G 562 HeatMaster 150 Jumbo HeatMaster 70 N and HeatMaster 100 N Without burner With ACV BG 2000 S premix gas burner...

Reviews: