TECHNICAL CHARACTERISTICS
DOMESTIC HOT WATER PERFORMANCES - Operating conditions: 70
0
C
HeatMaster
©
TC
TECHNICAL
DHW
T
0
Peak flow [liters/min.]
Continuous flow
Preheating
time [min]
10 min
20 min
30 min
40 min
50 min
60 min
l/h
kW
10 - 70
0
C
40
377
533
690
847
1004
1161
940
37,3
{
25
}
45
312
436
561
686
811
936
748
37,3
50
263
363
462
561
660
759
600
37,3
55
223
303
384
464
544
624
481
37,3
60
191
254
317
380
443
506
380
37,3
Operating conditions 70
0
C - Cold water 10
0
C
HM 35 TC
HM 85 TC
DHW
T
0
Peak flow [liters/min.]
Continuous flow
Preheating
time [min]
10 min
20 min
30 min
40 min
50 min
60 min
l/h
kW
10 - 70
0
C
40
606
983
1360
1737
2114
2491
2264
94,6
{
20
}
45
501
801
1102
1402
1702
2002
1801
94,6
50
422
663
903
1143
1383
1623
1445
94,6
55
358
551
744
937
1130
1323
1158
94,6
60
306
458
611
763
915
1067
914
94,6
2 x HM 85 TC
DHW
T
0
Peak flow [liters/min.]
Continuous flow
Preheating
time [min]
10 min
20 min
30 min
40 min
50 min
60 min
l/h
kW
10 - 70
0
C
40
1212
1966
2720
3474
4228
4982
4528
189,2
{
20
}
45
1002
1602
2204
2804
3404
4004
3602
189,2
50
844
1326
1806
2286
2766
3246
2890
189,2
55
716
1102
1488
1874
2260
2646
2316
189,2
60
612
916
1222
1526
1830
2134
1828
189,2
3 x HM 85 TC
DHW
T
0
Peak flow [liters/min.]
Continuous flow
Preheating
time [min]
10 min
20 min
30 min
40 min
50 min
60 min
l/h
kW
10 - 70
0
C
40
1818
2949
4080
5211
6342
7473
6792
283,8
{
20
}
45
1503
2403
3306
4206
5106
6006
5403
283,8
50
1266
1989
2709
3429
4149
4869
4335
283,8
55
1074
1653
2232
2811
3390
3969
3474
283,8
60
918
1374
1833
2289
2745
3201
2742
283,8
Summary of Contents for HeatMaster 35 TC
Page 1: ...HeatMaster TC TECHNICAL...
Page 27: ...27 Electric diagram Solar pump DHW circulating pump...
Page 31: ...31 Electric diagram Mixed HC pump close open...
Page 33: ...33 Electric diagram Direct HC pump Mixed HC pump close open...
Page 35: ...35 Electric diagram Direct HC pump Mixed HC pump 1 Mixed HC pump 2 open close open close...