![ACV HeatMaster 120 TC Installation, Operation And Maintenance Instructions Download Page 6](http://html1.mh-extra.com/html/acv/heatmaster-120-tc/heatmaster-120-tc_installation-operation-and-maintenance-instructions_3047123006.webp)
Addendum HeatMaster/WaterMaster Chimney Connections : A1005390 - ADD0080
* Designations and references (between brackets) are provided as information only. Please refer to the latest ACV brochure for more information and the correct references.
EN
Boiler M
odels
Conne
xion t
ype
Material /
Ø (mm)
Components *
Terminals
Pipes
Extensions
Bends
Measurement and con-
densate recovery
Accessories
Adapters
Hea
tM
ast
er 70-85-120
TC
W
at
erM
ast
er 70-85-120
C13
C33
PP - Galva
Ø 100/150
• Roof Terminal
(537D6300)
• Wall terminal kit
(537D6301)
Lengths :
• 250 mm (
537D6302)
• 500 mm (537D6303)
• 1000 mm (537D6304)
• 2000 mm (537D6517)
Sliding extension, straight
(+ 50 to 130 mm)
(537D6305)
• 43° - 45° (537D6306)
• 87° - 90° (537D6307)
• Measuring Tube
( 537D6308)
• Measuring T-piece with
inspection (537D6310)
• Weather Slate Steep
25°-45° (537D6209)
• Bracket Ø 150 mm
(537D6210)
• Weather Slate, Flat roof
(Ø 430 mm) (537D6208)
Concentric to parallel
Ø 100/150 mm - 2 x Ø 100
mm (537D6207)
Hea
tM
ast
er 70-85-120
TC
W
at
erM
ast
er 70-85-120
B23P
C53
SST
Ø 150
• Roof Terminal , flue
Ø 150
(537D6211)
• Wall terminal kit , flue,
Ø 150
(537D6212)
• Wall terminal kit, air,
Ø 100
(537D6213)
Lengths, flue, Ø 150 :
• 250 mm (
537D6214)
• 500 mm (537D6215)
• 1000 mm (537D6216)
Length, air, PVC Ø 100 :
• 500 mm (
537D6217)
Sliding extension, flue,
Ø 150
(537D6218)
• Flue, Ø 150, 45°
(537D6219)
• Flue, Ø 150, 90°
(537D6220)
• Air, Ø 100, 45°
(537D6221)
• Air, Ø 100, 90°
(537D6222)
Element for measurement
and recovery of conden-
sates, flue,
Ø 150
(537D6223)
• Weather Slate Steep
25°-45° (537D6209)
• Bracket Ø 150 mm
(537D6210)
• Weather Slate, Flat roof
(Ø 430 mm) (537D6208)
• Expander Ø 100 -
Ø 150 mm mandatory
(537D6293)
• Concentric to parallel
adapter Ø 100/150
mm - 2 x Ø 100 mm
(537D6207)
• Adapter Ø 80 - Ø 100
mm, air (537D6172)
Hea
tM
ast
er 70-85-120
TC
W
at
erM
ast
er 70-85-120
C13
C33
SST - SST
Ø 100/150
• Roof Terminal,
(537D6197)
• Wall terminal
(537D6198)
Lengths :
• 250 mm (
537D6199)
• 500 mm (537D6200)
• 1000 mm (537D6201)
Sliding extension (280 to
395 mm)
(537D6202)
• 43° - 45° (537D6203)
• 87° - 90° (537D6204)
Element for measurement
and recovery of conden-
sates, flue, (537D6226)
• Weather Slate Steep
25°-45° (537D6209)
• Bracket Ø 150 mm
(537D6210)
• Weather Slate, Flat roof
(Ø 430 mm) (537D6208)
Concentric to parallel
adapter Ø 100/150 mm - 2 x