ACV Delta Classic Installation, Operating And Servicing Instructions Download Page 14

INTERNATIONAL

ACV international n.v

KERKPLEIN, 39
B-1601 RUISBROEK - belgium
TEL.: +32 2 334 82 20
FAX: +32 2 378 16 49
E-MAIL: [email protected]

AUSTRALIA

ACV PACIFIC PTY.LTD

UNIT 7, 10 ANELLA AVENUE
CASTLE HILL NSW 2154 - AUSTRALIA
TEL.: +61 2 88 50 45 88
FAX: +61 2 88 50 45 99
E-MAIL: [email protected]

BELGIUM

ACV  BELGIUM nv/sa

KERKPLEIN, 39
B-1601 RUISBROEK-BELGIUM
TEL.: +32 2 334 82 40
FAX: +32 2 334 82 59
E-MAIL: [email protected]

CHILE

ALBIN TROTTER Y ACV LTDA

SAN PABLO 3800
QUINTA NORMAL - SANTIAGO - CHILE
TEL.:+56 2 772 01 69
FAX:+56 2 772 92 62/63
E-MAIL: [email protected]

CZECH REPUBLIC

ACV CR SPOL. s.r.o

NA KRECKU 365
CR-109 04 PRAHA 10 - CZECH REPUBLIC
TEL.:+420 2 720 83 341
FAX:+420 2 720 83 343
E-MAIL: [email protected]

DEUTSCHLAND

ACV DEUTSCHLAND Gmbh

GEWERBEGEBIET GARTENSTRASSE
D-08132 MÜLSEN ST.JACOB - DEUTSCHLAND
TEL.:+49 37601 311 30
FAX:+49 37601 311 31
E-MAIL: [email protected]

ESPAÑA

ACV ESPAÑA

C/ANTONIO GAUDI, 3
E-08349 CABRERA DE MAR - ESPANA
TEL.:+34 937 595 451
FAX:+34 937 593 498
E-MAIL: [email protected]

FRANCE

ACV FRANCE sa

31, RUE AMPERE - Z.I MI - PLAINE
F-69680 CHASSIEU - FRANCE
TEL.:+33 4 72 47 07 76
FAX:+33 4 72 47 08 72
E-MAIL: [email protected]

ITALIA

ACV ITALIA

VIA MALPIGHI 6
I-48018 FAENZA (RA) - ITALIA
TEL.:+39 0546 62 25 15
FAX:+39 0546 62 25 05
E-MAIL: [email protected]

NEDERLAND

ACV NEDERLAND bv

POSTBUS 350
NL-2980 AJ RIDDERKERK - NEDERLAND
TEL.:+31 180 42 10 55
FAX:+31 180 41 58 02
E-MAIL: [email protected]

POLAND

ACV POLSKA sp. z.o.o.

BUIRO GLOWNE 
PL-87 - 702 KONECK - POLAND
TEL.:+48 54 272 23 00
FAX:+48 54 272 23 01
E-MAIL: [email protected]

PORTUGAL

BOILERNOX LDA

RUA OUTEIRO DO POMAR
CASAL DO CEGO, FRACÇÃO C,
PAVILHÃO 3 - MARRAZES
2400-402 LEIRIA - PORTUGAL
TEL.:+351 244 837 239/40
FAX:+351 244 823 758
E-MAIL: [email protected]

RUSSIA

ACV RUSSIA

1/9, MALYI KISELNYI
103031 MOSCOW - RUSSIA
TEL.:+7 095 928 48 02 / +7 095 921 89 79
FAX:+7 095 928 08 77
E-MAIL: [email protected]

SLOVAK REPUBLIC

ACV SLOVAKIA s.r.o.

PLUHOVÁ 49
831 04 BRATISLAVA - SLOVAK REPUBLIC
TEL.:+421 2 444 62 276
FAX:+421 2 444 62 275
E-MAIL: [email protected]

UK

ACV UK Ltd

ST. DAVID’S BUSINESS PARK
DALGETY BAY - FIFE - KY11 9PF - SCOTLAND
TEL.:+44 1383 82 01 00
FAX:+44 1383 82 01 80
E-MAIL: [email protected]

USA

TRIANGLE TUBE PHASE III

FREEWAY CENTER - 1 TRIANGLE LANE
BLACKWOOD NJ 08012 - USA
TEL.:+1 856 228 8881
FAX:+1 856 228 3584
E-MAIL: [email protected]

ARGENTINA

TECNOPRACTICA

ALFEREZ BOUCHARD 4857
1605 CARAPACHAY - BUENOS AIRES
TEL.: +54 11 47 65 33 35
FAX: +54 11 47 65 43 07
E-MAIL: [email protected]

BRAZIL

SIMETAL INDUSTRIA E COMERCIO
DE FERRAMENTAS LTDA

RUA GERSON ANDREIS 535
95112 - 130 CAXIAS DO SUL - BRAZIL
TEL.: +55 54 227 12 44
FAX: +55 54 227 12 26
E-MAIL: [email protected]

BULGARIA

PROXIMUS ENGINEERING LTD

7 BIAL KREM STR.
9010 VARNA - BULGARIA
TEL.:+359 52 500 070
FAX:+359 52 301 131
E-MAIL: [email protected]

CHINA

BEIJING HUADIAN HT POWER TECHNOLOGY
DEVELOPMENT CO. LTD

ROOM B-912, TOWER B, COFCO PLAZA
N°. 8, JIANGUOMENNEI AVENUE
BEIJING 100005 - PEOPLE’S REPUBLIC OF CHINA
TEL.:+86 10 652 30 363/393 EXT 101
FAX:+86 10 652 27 071
E-MAIL: [email protected]

DENMARK

VARMEHUSET

FRICHSVEJ 40 A
8600 SILKEBORG - DENMARK
TEL.:+45 86 82 63 55
FAX:+45 86 82 65 03
E-MAIL: [email protected]

ESTONIA

TERMOX AS

TAHE 112A
51013 TARTU - ESTONIA
TEL.:+372 736 73 39
FAX:+372 736 73 44
E-MAIL: [email protected]

GREECE

ESTIAS

MARASLI STREET 7
54248 THESSALONIKI - GREECE
TEL.:+30 310 31 98 77
FAX:+30 310 31 97 22
E-MAIL: [email protected]

ÎLE MAURICE

SOTRATECH

29, RUE MELDRUM
BEAU BASSIN - ÎLE MAURICE
TEL.:+230 46 76 970
FAX:+230 46 76 971
E-MAIL: [email protected]

LITHUANIA

UAB “GILIUS IR KO”

SAVARNORIU PR. 192
3000 KAUNAS - LITHUANIA
TEL.:+370 7 308 930
FAX:+370 7 731 796

MAROC

CASATHERM

PLACE EL YASSIR
20300 CASABLANCA - MAROC
TEL.:+212 22 40 15 23
FAX:+212 22 24 04 86

MOLDAVIA

STIMEX - PRIM S.R.L.

STR BUCURESTI, 60A
2012 CHISINAU - MOLDAVIA
TEL.:+37 32 22 46 75
FAX:+37 32 27 24 56
E-MAIL: [email protected]

ÖSTERREICH

PROTHERM HEIZUNGSTECHNIK Gmbh

TRAUNUFERSTRASSE 113
4052 ANSFELDEN - ÖSTERREICH
TEL.:+43 7229 804 82
FAX:+43 7229 804 92
E-MAIL: [email protected]

ROMANIA

SC TRUST  EURO THERM  SA

D.N PIATRA NEAMT - ROMAN 
km 2 C.P 5 O.P 3 jud. Neamt
5600 PIATRA NEAMT - ROMANIA
TEL.:+40 33 20 62 06
FAX:+40 33 20 62 00
E-MAIL: [email protected]

SLOVENIA

Z*MAJ d.o.o.

CESTA OF 49
1420 TRBOVLJE - SLOVENIA
TEL.:+386 356 32 830
FAX:+386 356 32 831
E-MAIL: [email protected]

SWEDEN

WÄRMEPRODUKTER I KLIPPAN AB

TEMPLAREGATAN 7
26435 KLIPPAN - SWEDEN
TEL.:+46 435 184 10
FAX:+46 435 184 02
E-MAIL: [email protected]

TUNISIE

SO.CO.ME CHAUMAX

BOÎTE POSTALE N°44
1002 TUNIS - TUNISIE
TEL.:+216 71 78 15 91
FAX:+216 71 78 87 31

UKRAINE

UKRTEPLOSERVICE LTD

PR. LAGUTENKO 14
83086 DONETSK - UKRAINE
TEL.:+38 062 382 60 47/48
FAX:+38 062 335 16 89
E-MAIL: [email protected]

Summary of Contents for Delta Classic

Page 1: ...NG AND SERVICING INSTRUCTIONS DELTA Classic Combination boiler with atmospheric burner ACV reserves the right to modality the technical specifications and components of its products without prior notice 664Y0100 05 11 2002 ...

Page 2: ...ooting 6 4 SERVICING 6 4 1 Recommendation 6 4 2 Servicing the gas boiler 6 4 3 Servicing the safety devices 6 4 4 Servicing the burner 7 4 5 Emptying the boiler 7 4 6 Spare parts 7 5 DESCRIPTION 8 5 1 Overview 8 5 2 Description of operation 8 5 3 Design features 9 6 TECHNICAL SPECIFICATION 10 6 1 Effective dimensions 10 6 2 Maximum operating conditions 10 6 3 Domestic hot water performance 10 6 4 ...

Page 3: ...ulations 2 2 2 CENTRAL HEATING CONNECTION 2 2 2 1 Examples of basic circuit configurations The drain valve and safety valve must be connected to the sewer drain 1 3 way manual motorisable mixer valve 2 Safety valve pre set to 3 bar with pressure gauge 3 Circulator 4 Non return valve 5 System filling valve 6 Expansion tank 7 Room thermostat 8 ACV 13 controller see controller kit page 5 9 Central he...

Page 4: ...Hot water expansion tank Installing a hot water expansion tank avoids any risk of pressure surges due to water hammer 2 2 3 4 Hot water circulation If the tank is situated a long way from the point of use then installing a closed return circuit can provide a faster supply of hot water always available 2 2 3 5 Description 1 Safety unit 2 Pressure reducer 3 Thermostatic mixing valve 4 Hot water circ...

Page 5: ...Orange N Black B Blue R Red T Green yellow 1 2 C L1 L1 N T1 T2 N T1 T2 S3 S3 N L1 230V 50 Hz 6A M R B B O B B O M M T N N 1O 11 9 2 8 7 3 6 1 12 2 4 1 3 5 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 bl n z br SQK 349 QAAD50 QAAD70 QAC32 QAD22 P1 B5 B9 B3 B2 P1 Y1 Y2 N B5 B9 B3 B2 B2 Water temperature detector B9 Outside temperature detector...

Page 6: ...in the boiler room by the electrician 2 1 3 3 2 5 4 7 1 8 6 4 1 RECOMMENDATION ACV advises that boilers should be serviced at least once a year The burner must be serviced and tested by a competent engineer 4 2 SERVICING THE GAS BOILER 1 Switch off the power at the mains switch outside the boiler and close the gas tap 2 Set the on off switch on the control panel to the OFF position 3 Release and r...

Page 7: ... When the boiler is empty return the isolating and safety valves to their initial positions 4 5 2 EMPTYING THE HOT WATER TANK 1 Switch off the mains power to the boiler at the external switch installed by the electrician 2 Relieve the pressure in the primary circuit 3 Close valves A and B 4 Open valves C and D first C then D 5 Let the water drain away 6 After emptying return the valves to their in...

Page 8: ... heating system or the domestic hot water system the thermostat starts the burner The combustion gases quickly heat up the primary fluid creating a natural circulation around the tank 5 2 2 DOMESTIC HOT WATER HEATED INDIRECTLY This circulation facilitates heat exchange between the primary fluid and the domestic water which takes place all over the tank surface The corrugations on the inner and out...

Page 9: ...ulation coefficient sprayed on without the use of CFCs 5 3 5 JACKET The boiler is covered by a steel jacket which has been scoured and phosphated before being stove enamelled at 220 C 5 3 6 BURNER DELTA Classic boilers are fitted with an atmospheric burner with elec tric ignition IMPORTANT When starting the burner for the first time and when servicing it refer to the technical instructions supplie...

Page 10: ...hot water performances G20 G25 G30 P30 Operating at 80 c Peak delivery at 40 C 6T 30 C litres 10 266 339 339 339 Peak delivery at 40 C 6T 30 C litres 60 820 1025 1151 1161 Continuous delivery 40 C 6T 30 C litres h 665 823 975 986 Operating at 80 c Initial heating time minutes 40 29 24 24 After draw off of 140 l à 45 C minutes 16 12 10 10 Specific delivery litres minutes 11 14 14 5 14 5 Results obt...

Page 11: ...point 11 G20 G25 G30 P30 Gas G20 20 mbar I E2 I 2E LL Burner pressure mbar 13 3 12 8 12 3 Flow rate m3 h 2 76 3 50 4 13 Gas G25 25 mbar I 2L Burner pressure mbar 13 4 13 4 13 4 Flow rate m3 h 3 10 3 88 4 50 Gas G31 37 50 mbar I 3P Burner pressure mbar 28 5 Flow rate m3 h 1 64 Injectorr Ø 1 100 mm 450 470 510 3x190 BE FR I E2 AT DK ES GB I 2H IT PT IE SE BE FR ES GB I 3P IE PT NL I 2L LU DE I 2ELL ...

Page 12: ...the temperature on the thermostat 1 to save energy If there is not enough hot water we recommend setting the thermostat 1 to its maximum value When the next heating season begins simply select Winter to reactivate the heating system 4 Thermometer item 4 Fig 21 Reads the temperature of the boiler primary circuit central heating directly 5 Regulator item 5 Fig 21 See the user instructions enclosed i...

Page 13: ...ights replace the cover If the burner is not working isolate the electricity supply before attempting to reset the safety thermostat 4 Remove the front panel of the casing and reset the safety thermostat positioned on top of the boiler Wait until the boiler temperature is below 60 C Then replace the casing front panel 5 If the burner lights replace the cover 6 If the fault persists notify the inst...

Page 14: ...NGLE TUBE PHASE III FREEWAY CENTER 1 TRIANGLE LANE BLACKWOOD NJ 08012 USA TEL 1 856 228 8881 FAX 1 856 228 3584 E MAIL sales triangletube com ARGENTINA TECNOPRACTICA ALFEREZ BOUCHARD 4857 1605 CARAPACHAY BUENOS AIRES TEL 54 11 47 65 33 35 FAX 54 11 47 65 43 07 E MAIL jchas tecnopractica com BRAZIL SIMETAL INDUSTRIA E COMERCIO DE FERRAMENTAS LTDA RUA GERSON ANDREIS 535 95112 130 CAXIAS DO SUL BRAZI...