INSTALLATION INSTRUCTIONS
Min.
300 mm
Min.
220 mm
Min. 25 mm
Min. 25 mm
prestige
- The boiler must be mounted on a non-flammable wall.
- Drill two 10 mm diameter holes, spaced as indicated on
the above drawing.
- Secure the wall-mount bracket with the delivered anchor
screws.
- Hook the boiler on the bracket.
BOILER ROOM
- Make sure that all air vents are unobstructed any times.
- Do not store any flammable products in the boiler room.
- Do not store any corrosive products, paint, solvents, salts,
chlorine products and other detergent products near the
appliance.
- If you smell gas, do not switch on any lights, turn off the
gas tap at the meter, ventilate the rooms and contact your
installer.
101,6 mm
101,6 mm
48,4 mm
53,2 mm
53,2 mm
48,4 mm
WALL MOUNTING OF THE BOILER
288
48
I / J
K
I
K
65
316
J
435
prestige
C
D
E
F
B
H
G
A
DIMENSIONS
50 / 75
A mm
980
B mm
500
C mm
392
D mm
100
E mm
150
F mm
175
G mm
930
H mm
400
ACCESSIBILITY
The appliance must be positioned in such a way to be
accessible any time. In addition, the following distances are
required around the appliance.
I. Heating supply 1”1/4 [F]
J. Heating
return
1”1/4
[F]
K. Gas connection 3/4” [M]
Summary of Contents for 75