AcuRite 01602BPDIA2 Instruction Manual Download Page 7

7

A B C

SETUP

5-in-1 Sensor Setup

1

A-B-C Switch

Set to match 

display unit

2

Install Batteries 

4 AA Batteries

3

Rain Gauge Stabilizer

Remove and discard

Set the A-B-C Switch

Locate the A-B-C switch inside the 

battery compartment. Set the A-B-C 

switch to A, B or C. You must select 

the same letter choices for both the 

sensor and the display unit in order 

for the units to synchronize. 

Install or Replace Batteries

Batteries MUST be installed for 

this product to operate. AcuRite 

recommends high quality alkaline 

or lithium batteries for the best 

product performance. Heavy duty 

or rechargeable batteries are not 

recommended.
The 5-in-1 sensor requires lithium 

batteries in low temperature 

conditions. Cold temperatures can 

cause alkaline batteries to function 

improperly. Use lithium batteries in 

the 5-in-1 sensor for temperatures 

below -4ºF / -20ºC.
1. Slide off the battery   

 

  compartment cover. 
2. Insert 4 x AA batteries into the 

  battery compartment, as  

  shown. Follow the polarity  

  (+/-) diagram in the battery  

 compartment.
3. Replace the battery cover.

Remove Rain Gauge Stabilizer

Locate and remove the rain gauge 

stabilizer (plastic tab) taped into 

the bottom of the sensor. The rain 

gauge will not function until this is 

removed.

2

3

1

Summary of Contents for 01602BPDIA2

Page 1: ...ts 5 in 1 3 Features Display Unit 4 Back of Display Unit 6 Setup 7 5 in 1 Sensor Setup 7 Display Unit Setup 8 Set the Time Date 9 Measurement Units 10 Placement Guidelines 11 5 in 1 Sensor Installatio...

Page 2: ...D screen prior to using this product Locate the tab and peel off to remove Package Contents 1 Display unit with tabletop stand 2 5 in 1 sensor 3 Sensor mounting bracket 4 Mounting hardware 5 Snap in d...

Page 3: ...ion heating resulting in more accurate temperature measurement 3 A B C Switch ID code that must match display s A B C switch to ensure units synchronize 4 Battery Compartment 5 Temperature Humidity Se...

Page 4: ...4 Features Benefits Display Unit 1 31 32 33 34 30 29 28 27 26 25 24 22 20 23 21 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 16...

Page 5: ...ll time low and date recorded for current category selected on display 16 Press twice for all time high and date recorded 20 Record Lows Shown for current category selected on the display 16 21 Clear...

Page 6: ...asy wall mounting 3 Battery Compartment Cover 4 A B C Switch ID code that must match 5 in 1 sensor s A B C switch to ensure units synchronize 5 Clear Today Clears data recorded since 12 00am 6 Reset F...

Page 7: ...ne or lithium batteries for the best product performance Heavy duty or rechargeable batteries are not recommended The 5 in 1 sensor requires lithium batteries in low temperature conditions Cold temper...

Page 8: ...WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an...

Page 9: ...irm hour selection 5 Press the up or down arrows to adjust minutes 6 Press the button to confirm minute selection The clock is now set Set the Date 1 Press the up or down arrow buttons until SET DATE...

Page 10: ...Category part of the display unit 2 Press the button to set the unit preference 3 Press the up or down arrows to select STAND for standard or METRIC for metric units 4 Press the button to confirm you...

Page 11: ...away from large metallic items thick walls metal surfaces or other objects that may limit wireless communication PREVENT WIRELESS INTERFERENCE Place both units at least 3 feet 9 m away from electroni...

Page 12: ...he hardware bag 2 Insert the mounting base into the hole on the bottom of the sensor 3 Make sure the arrows on the top of the sensor are pointed in the proper direction and the bubble level is centere...

Page 13: ...ther forecaster displays the current pressure and the direction it s trending FALLING STEADY or RISING Rainfall Event The rainfall feature tracks rain accumulation over all time the current month and...

Page 14: ...lue by pressing the up or down arrow buttons 4 Press the button to confirm a value 5 Next press the button to activate the alarm The alarm ON indicator will highlight on the display Alarm is now progr...

Page 15: ...tall batteries in display unit 4 Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Outdoor temperature is flashing or showing dashes Flashing of the...

Page 16: ...ou may need to clean inside the sensor Video available at www acurite com 5in1 Inaccurate wind readings What is wind reading being compared to Pro weather stations are typically mounted at 30 ft high...

Page 17: ...Cup Remove and empty rain collector debris filter The debris filter is located in the rain collector funnel Remove from the top by gently squeezing and pulling out Clean the Wind Vane Anemometer Remo...

Page 18: ...er should take more than 20 minutes to empty a quicker period will result in inaccurate calibration Try to simulate a normal steady rainfall When cup is empty of water display unit should register 1 0...

Page 19: ...llowing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to whic...

Page 20: ...es are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liab...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...uRite uses patented technology Visit www AcuRite com patents for details Printed in China 01602BPDIA2 INST 020915 It s More than Accurate it s AcuRite offers an extensive assortment of precision instr...

Reviews: