Programmable Alarms

This display features programmable alarms that sound an alert to notify you 

when a value (for temperature or humidity) has been reached or exceeded. 

When an alarm is triggered, the display emits an audible beep and flashes data 

in the affected category. You can customize the alarms by turning ON or OFF 

the alarms you’d like activated or deactivated, and by inputting your own values  

to trigger the alarm. 

Setup an Alarm

1.  Press and release the “

 ” button until the reading for which you wish to 

 set an alarm is shown on the display. “ ” will be shown.

2. Press and release the  “ “ or “ “ buttons until “

 ” appears.

3. Press and release the “SET” button. The current HIGH alarm value will be 

 shown.

4. Press and release the “ “ or “ “ buttons to adjust the alarm’s HIGH value.
5. Press and release the “SET” button. The current LOW alarm value will be  

 shown.

6. Press and release the “ “ or “ “ buttons to adjust the alarm’s LOW value.
7.  Press and release the “SET” button to end alarm adjustments, OR press 

 and release the “

 ” button to adjust the next alarm’s values.

Disable an Alarm 

1.  Press and release the “

 ” button until the reading for which you wish to 

  disable an alarm is shown on the display. “

 ” will be shown.

2. Press and release the“ “ or “ “ buttons until “ ” appears. 
3. Press and release the “

 ” button to cycle to the next reading. 

4. Repeat steps 1-3, as needed.

Note:

 To disable ALL alarms at once, press and HOLD the “

 ” button for  

10 seconds.
You will automatically exit alarm SET MODE if no buttons are pressed for  

10 seconds. Enter alarm SET MODE at any time by pressing the “

 ” button.

Summary of Contents for 00484

Page 1: ...nstructions 2 Package Contents 2 Product Registration 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Set the Time Date Units 7 Backlight Settings 7 Pla...

Page 2: ...rmance please read this manual in its entirety and retain it for future reference Unpacking Instructions Remove the protective film that is applied to the LCD screen prior to using this product Locate...

Page 3: ...dicator 8 Date 9 Display Low Battery Indicator 10 Clock 11 Current Indoor Temperature Arrow icon indicates the direction temperature is trending 12 Humidity Level Indicator Indicates a high low or ide...

Page 4: ...3 Button For alarm setup 4 RESET Button Full reset to factory defaults 5 Foldout Tabletop Stand 6 Battery Compartment 7 Plug in for Power Adapter 8 Battery Compartment Cover 9 Integrated Hang Hole Fo...

Page 5: ...ires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4 F 20 C 1 Slide o...

Page 6: ...g in the power adapter as the main power source for this product 1 2 2 Plug in Power Adapter PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOC...

Page 7: ...F or C BAROMETRIC PRESSURE UNITS inHg or hPa You will automatically exit SETUP MODE if no buttons are pressed for 8 seconds Enter setup mode at any time by pressing the SET button Display Backlight Se...

Page 8: ...ell covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate...

Page 9: ...to 24 hours by collecting data from the sensor in your backyard It generates a forecast with pinpoint accuracy personalized for your exact location Depending on your model weather forecast icons will...

Page 10: ...alarm value will be shown 4 Press and release the or buttons to adjust the alarm s HIGH value 5 Press and release the SET button The current LOW alarm value will be shown 6 Press and release the or bu...

Page 11: ...mperature or humidity Make sure both the display and sensor are placed out of direct sunlight and away from any heat sources or vents see page 8 Make sure the display is positioned away from moisture...

Page 12: ...least 5 seconds 2 Once in calibration mode the preference you are currently setting will be highlighted on the display 3 Press the or buttons to calibrate the data value higher or lower from the actu...

Page 13: ...ss and release the SET button three times to enter barometric pressure calibration mode 4 Press the or buttons to calibrate the pressure higher or lower 5 Press the SET button to confirm the calibrati...

Page 14: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Page 15: ...itation of incidental or consequential damages so the above limitation or exclusion may not apply to you We further disclaim liability from personal injury relating to our products to the extent permi...

Page 16: ...AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 00506 INST 072717 It s more than accurate it s AcuRite offers an extensive assortment of precision instrume...

Reviews: