Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
iNSTALLATiON iNSTRUCTiONS
RHYTHM SERiES
©2014 Acuity Brands Lighting, Inc.
7/29/14
INS-RHYTHM
9144 Deering Avenue | Chatsworth, CA 91311 | www.hydrel.com
Phone: 866.533.9901 | Fax: 866.533.5291
Fixture to SSBR Surface Box Connection
1) Route fixture cord along fixture and
Mounting Plate
Rod
(H) and secure with provided
Wire Keepers
(I) (J).
2) Trim excess cord at
SSBR
, strip back jacket approximately 4”, and slide through
½” Cord Seal
(K) provided.
a. Note:
½” Cord Seal
(K) may be utilized on either side of
SSBR
as required by installation.
3) Make electrical load connections as indicated on the labeled conductors and per all NEC and local code
requirements.
SSBR
Mounting Plate Rod
Wire Keepers
Wire Keepers
Cord Seal
H
I
J
K
J
H
I
K
WARNiNG
:
FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE
For your protection, read and follow these warnings and instructions carefully before installing this fixture. These instructions do not attempt to cover all installation
situations. If you do not understand these instructions or additional information is required, contact Hydrel Lighting or your local Hydrel Lighting distributor.
DISCONTINUED