DISPLAY UNIT FRONT

1.  Current Outdoor Temperature
2. Outdoor Low Temperature Record 

  Lowest temperature recorded since  

 midnight.

3. Outdoor High Temperature Record 

  Highest temperature recorded since  

 midnight.

4. 12 to 24 Hour Weather Forecast 

   Self-Calibrating Forecasting pulls data 

from the outdoor sensor to generate 

your personal forecast. 

5. Learning Mode Icon

 

   Disappears after weather forecast  

self-calibration is complete.

6.   Intelli-Time

®

 Clock 

Automatically updates for  

Daylight Saving Time.

7.  Time Zone 
8. Current Indoor Temperature
9. “ “ Arrow 

  for setup preferences.

10. Humidity Level Icon 

 

Indicates a high, low or ideal 

  indoor humidity level.

11. “

“ Button 

  for setup preferences.

12. Display Unit Low Battery Indicator 
13. “

“ Arrow 

  for setup preferences.

14. Current Indoor Humidity
15. Date
16. Day of the Week
17.  Pressure History Chart 

 

Displays the past 12 hours of data for  

  barometric pressure.

18. Current Barometric Pressure 

 

FALLING, STEADY or RISING  

  indicates the direction pressure is  

 trending.

19. Outdoor Low Humidity Record 

  Lowest humidity recorded since  

 midnight.

20. Outdoor High Humidity Record 

  Highest humidity recorded since  

 midnight.

21. Current Outdoor Humidity
22. Historical Barometric Pressure 

 

Pressure reading 12 hours ago.

23. Outdoor Sensor Signal Strength
24. Sensor Low Battery Indicator 
25.  Momentary Backlight Button 

Activates momentary backlight.

DISPLAY UNIT BACK

26.  Integrated Hang Hole 

for easy wall mounting.

27.   A-B-C  Switch 

ID code that must match sensor’s 

A-B-C switch to ensure units 

synchronize.

28. Reset 

 

Full reset to factory defaults.

29. Battery Compartment
30. Battery Compartment Cover

Summary of Contents for 1086

Page 1: ... 2 Product Registration 2 Features Benefits Sensor 2 Features Benefits Display 3 Setup 5 Sensor Setup 5 Display Setup 6 Intelli Time Clock 7 Set the Time Date Units 7 Placement Guidelines 8 Using the Weather Station 9 Troubleshooting 10 Care Maintenance 12 Replace Intelli Time Battery 12 Specifications 13 FCC Information 13 Customer Support 14 Warranty 14 Weather Station model 01086 ...

Page 2: ...lay unit with tabletop stand 2 Outdoor sensor 3 Instruction Manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product Features Benefits 4 3 2 1 5 OUTDOOR SENSOR 1 Integrated Hanger For easy placement 2 Wireless Signal Indicator Flashes when data is being sent to the display u...

Page 3: ...3 17 18 20 19 21 15 16 Features Benefits DISPLAY UNIT FRONT 2 3 1 4 5 6 7 8 RESET 30 26 27 28 29 9 11 12 13 14 25 23 24 22 BACK OF DISPLAY UNIT 10 ...

Page 4: ...ery Indicator 13 Arrow for setup preferences 14 Current Indoor Humidity 15 Date 16 Day of the Week 17 Pressure History Chart Displays the past 12 hours of data for barometric pressure 18 Current Barometric Pressure FALLING STEADY or RISING indicates the direction pressure is trending 19 Outdoor Low Humidity Record Lowest humidity recorded since midnight 20 Outdoor High Humidity Record Highest humi...

Page 5: ... batteries are not recommended The sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the sensor for temperatures below 4ºF 20ºC 1 Slide off the battery compartment cover Take note of the A B C switch setting inside the battery compartment 2 Insert 2 x AA batteries into the battery compartme...

Page 6: ...es in fire as batteries may explode or leak DO NOT mix old and new batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals Display Unit Setup Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You must select the same letter choi...

Page 7: ... release the or V buttons press and HOLD to fast adjust To save your adjustments press and release the button again to adjust the next preference The preference set order is as follows TIME ZONE PST MST CST EST AST HAST AKST DST Daylight Saving Time ON or OFF CLOCK HOUR CLOCK MINUTE CALENDAR DATE CALENDAR MONTH CALENDAR YEAR TEMPERATURE SCALE ºF or ºC BAROMETRIC PRESSURE SCALE inHg or hPa If you l...

Page 8: ...e a well covered tree branch The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor Important Placement Guidelines To ensure accurate temperature measurement place units out of direct sunlight and away from any heat sources or vents Display unit and outdoor sensor must be within 330 ft 100 m of each other To maximize wireless r...

Page 9: ...ric Pressure Subtle variations in barometric pressure greatly impact the weather This weather center displays the current pressure and indicates the direction the pressure is trending FALLING STEADY or RISING The history chart lets you monitor the change in pressure over time Humidity Level Icon The Humidity Level Icon easily conveys a low high or ideal indoor humidity level for your home and heal...

Page 10: ...doors and remove batteries from each 2 Make sure the A B C switch on both units match 3 Reinstall batteries in the outdoor sensor 4 Reinstall batteries in the display unit 5 Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Sometimes changing to a different channel can help Inaccurate forecast Weather Forecast icon predicts conditions for the nex...

Page 11: ...Check that the batteries are installed correctly Batteries may need to be replaced Reset the display by pressing the reset button located on the back of the display unit Date and time will need to be entered after a reset The unit lost power or batteries were changed and the time is not correct The Intelli Time battery needs to be replaced see page 12 Once the new battery is installed time and dat...

Page 12: ...lace Intelli Time Clock Battery Intelli Time technology is powered by a pre installed coin cell battery that stores the time and date settings The battery has a shelf life of several years To replace the Intelli Time battery 1 Locate the coin cell battery compartment door on the back of the display unit Unscrew and remove the compartment cover 2 Insert 1 x CR2032 coin cell battery into the battery...

Page 13: ...ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipm...

Page 14: ...ies are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or con...

Page 15: ...15 ...

Page 16: ...s AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 01086 INST 061914 It s more than accurate it s AcuRite offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature Humidity Weather Alert Radio Kitchen Thermometers Timers C...

Reviews: