ActSafe ACX POWER ASCENDER Quick Start Manual Download Page 4

ActSafe Systems AB  
Sagbäcksvägen 13  
437 31 Lindome 
Sweden

T: 

+46 31 65 56 60 

E: 

[email protected]

www.actsafe.se

Contact ActSafe or your local ActSafe Ascender  
distributor for more information.

ActSafe Quick Start Guide Rev. 2.0 

The Remote Control can be used for  

a multitude of applications for both  

personnel and equipment lifting. 

 

 The ACX Ascender can be operated  

by a Remote Control to a distance of 

up to 150 metres (492 ft) in direct line 

of sight.

 

 The Remote Control will override  

the throttle control on the Ascender. 

Once it is in use, it will not be 

possible to use the Ascender by 

its own controls. If the Remote 

Control is not used for 10 seconds, 

control is automatically returned to 

the Ascender. Control is instantly 

returned to the Ascender when  

the remote is turned off with the 

Power button.

150 m (492 ft)

UP/Speed Selection

Speed Indicator 

DOWN/Speed Selection

Power Button

Link and Power LEDs

USB Protection Cap 

Connection Point

Activate the Remote 

Control by pushing  

the Power Button. 

1. Activation and connection

The green ‘POWER‘  

LED will show and the 

blue ‘LINK’ LED will  

start to blink for a 

few seconds whilst 

a connection is 

established with  

the Ascender.

Once connected, the  

blue ’LINK’ LED on the 

Remote Control will  

be lit continuously. 

Select between 3  

speeds in both ascent 

and descent: 20%,  

50% and 100%.

The speeds can be  

set by a short push 

of the ‘UP’ or ‘DOWN’ 

button and the LED  

bar will indicate the 

selected speed.

Short 

press

3. Set the Ascender speed

20%

50%

100%

By pushing either the 

‘UP’ or ‘DOWN’ button 

the Remote Control will 

take over the control  

of the Ascender and  

the Ascender will  

stop immediately.

The green LED on  

the Ascender will turn 

blue to indicate control 

has been taken over  

by the Remote Control.

2. Take control of the Ascender

Short 

press

H

Controls

H

Controls Summary

Summary of Contents for ACX POWER ASCENDER

Page 1: ...be required by your national regulations For any purpose other than that for which it has been designed In an explosive environment If modified in any way by anyone other than ActSafe Systems After a free fall from a height of more than 0 5 m 2 ft or any other severe impact onto a hard surface If subjected to misuse in any way so that parts or components might have been damaged The Ascender system...

Page 2: ...res Ascenders and especially batteries should be stored between 5 C 1 F and 25 C 77 F for optimal performance and service life For more info see section E 08 10 C 14 F 0 C 32 F 20 C 68 F 40 C 104 F RECOMMENDATION In cold environments maintain optimal Battery temperature and performance by keeping the Battery in the transportation box as long as possible i 1 Connect the Charger to mains supply 2 Co...

Page 3: ...ely turn the Ascender off 2 Reset the Emergency Stop by pulling out the button Throttle Travel down Travel up Emergency Descent The dead rope must never be loaded in order to avoid side loading on the Rope Guide Do not build tramways using the primary rope as shown in the picture CAUTION When descending make sure the rope is fed neatly into the Rope Grab so that there are no kinks or twists in the...

Page 4: ...on 150 m 492 ft UP Speed Selection Speed Indicator DOWN Speed Selection Power Button Link and Power LEDs USB Protection Cap Connection Point Activate the Remote Control by pushing the Power Button 1 Activation and connection The green POWER LED will show and the blue LINK LED will start to blink for a few seconds whilst a connection is established with the Ascender Once connected the blue LINK LED...