ActSafe ACX POWER ASCENDER Quick Start Manual Download Page 2

C

Batteries 

ActSafe recommends users to follow the Battery care  

guidelines below for optimal lifetime and performance: 

 

»

 

Battery can stay connected to ACX during transport or short  

term storage (1 week). For longer storage, disconnect the  

battery and do a maintenance charge every 3 months

 

»

 Always charge batteries as soon as possible after use

 

»

 Disconnect batteries from the charger after charging

 

»

 Always store batteries fully charged

 

»

 Store batteries between 5°C (41°F) and 25°C (77°F)

 

 

 

 

DANGER

Not following instructions may result in 

DAMAGE TO PROPERTY, SERIOUS  

BODILY INJURY OR DEATH.

Note – Battery lifetime

Under normal service conditions it is expected 

that the Battery will last 3-5 years or around 

approximately 500 charging cycles. Lifetime  

is dependent on how much load is lifted and 

the operational temperatures. 

 

 

Lifting distances

Lifting distances with battery powered ACX with 100 kg (220 lb),  

150 kg (330 lb) and 200 kg (440 lb) at different temperatures. 

250 m

200 m

Lifting distance

Load

100 kg 

 (220 lb)

150 kg 

(330 lb)

200 kg 

(440 lb)

150 m

100 m

50 m

820 ft

656 ft

492 ft

328 ft

164 ft

0

0

Note

All values on this page apply to operating 

temperatures. Ascenders and especially 

batteries should be stored between 5°C (1°F) 

and 25°C (77°F) for optimal performance and 

service life. For more info see section E.08.

 

-10°C (14°F)

0°C (32°F)

20°C (68°F)

40°C (104°F)

RECOMMENDATION

In cold environments, maintain optimal Battery 

temperature and performance by keeping  

the Battery in the transportation box as long 

as possible. 

 i

1.

  Connect the Charger to mains supply. 

2.

 Connect Battery to charger.

3.

  Constant charging controlled by BMS. The Battery  

is full when all 4 Battery LEDs are continuously lit.

4.

  10 minutes balancing and all LEDs are lit  

continuously. The LEDs slowly pulsate when  

balancing is completed.

5.

 Disconnect Battery from charger.

6.

  Disconnect Charger from main supply.

 Battery Status 

 

 

The Battery Status Indicator is positioned at the back of the Battery 

and can be activated by pushing the button next to the LEDs.  

The Battery Indicator has 4 LEDs each representing 25% charge.

LEDs

Capacity

1 red, 3 green

75-100%

1 red, 2 green

50-75%

1 red, 1 green

25-50%

1 red

0-25%

B

Note

Batteries are fully regulated as Dangerous 
Goods (Class 9 UN3480 Lithium Ion Batteries)  
and must be handled and shipped accordingly. 
A defective Battery must not be shipped.

 

RECOMMENDATION

Empty a fully charged Battery for improved 
descending by running the Ascender 
unloaded for 2 minutes at full speed before 
the operation.

 

 i

D

Summary of Contents for ACX POWER ASCENDER

Page 1: ...be required by your national regulations For any purpose other than that for which it has been designed In an explosive environment If modified in any way by anyone other than ActSafe Systems After a free fall from a height of more than 0 5 m 2 ft or any other severe impact onto a hard surface If subjected to misuse in any way so that parts or components might have been damaged The Ascender system...

Page 2: ...res Ascenders and especially batteries should be stored between 5 C 1 F and 25 C 77 F for optimal performance and service life For more info see section E 08 10 C 14 F 0 C 32 F 20 C 68 F 40 C 104 F RECOMMENDATION In cold environments maintain optimal Battery temperature and performance by keeping the Battery in the transportation box as long as possible i 1 Connect the Charger to mains supply 2 Co...

Page 3: ...ely turn the Ascender off 2 Reset the Emergency Stop by pulling out the button Throttle Travel down Travel up Emergency Descent The dead rope must never be loaded in order to avoid side loading on the Rope Guide Do not build tramways using the primary rope as shown in the picture CAUTION When descending make sure the rope is fed neatly into the Rope Grab so that there are no kinks or twists in the...

Page 4: ...on 150 m 492 ft UP Speed Selection Speed Indicator DOWN Speed Selection Power Button Link and Power LEDs USB Protection Cap Connection Point Activate the Remote Control by pushing the Power Button 1 Activation and connection The green POWER LED will show and the blue LINK LED will start to blink for a few seconds whilst a connection is established with the Ascender Once connected the blue LINK LED...

Reviews: