background image

Indicators on LCD

Transmission Indicator

Temperature / Timer display

Fan speed display

Sleep Display

Mode display

ON/OFF display

The transmission indicator lights when remote

controller transmits signals to the indoor unit.

Displays the current operation mode. Including

auto (

), cool ( ), dry (

), heat (

) (Not

applicable to cooling only models), fan (

)

and back to auto (

).

Displays the temperature setting (17 C~30 C). When

you set the operating mode to FAN, no temperature

setting is displayed. And

O

O

if in the TIMER mode, shows

the ON and OFF settings of the TIMER.

Displayed by pressing the ON/OFF button.

Press the ON/OFF button again to remove.

Displays the selected fan speed, AUTO(no display)

and three fan speed levels " " (LOW) "

(HIGH) can be indicated. The fan speed is AUTO

when the operating mode is either AUTO or DRY.

" (MED)

" "

Displayed under sleeping operation.

Press the SLEEP button again to remove.

Note:

All indicators shown in the diagram are for instruction purposes

only. But during the actual operation only the relative functional

signs are shown on the display window.

Lock Display

Displayed when LOCK mode is activated.

FOLLOW ME Display

Displayed when Follow me function is activated.

auto cool dry heat fan

sleep follow me lock run

SET TEMP. TIMER ONOFF

How to use the buttons

Cooling /Heating/Fan operation

MODE

UP/DOWN

FAN

ON/OFF

Ensure the unit is plugged in and power is

available.

1. Press the

button to select COOL,

HEAT or FAN mode.

2. Press the

buttons to set the

desired temperature.

3. Press the

button to select the fan speed

in four steps- Auto, Low, Med,or High.

4. Press the

button to start the air

conditioner.

The temperature can

be set within a range of 17 C~ 30 C in 1 C

increments.

O

O

O

In the FAN mode, the set temperature is not

displayed on the remote controller and you are not

able to control the room temperature either. In this

case, only step 1, 3 and 4 may be performed.

NOTE

Auto operation

MODE

UP/DOWN

ON/OFF

Ensure the unit is plugged in and power is

available. The OPERATION indicator on the

display panel of the indoor unit starts flashing.

1. Press the

button to select Auto.

2. Press the

button to set the

desired temperature. The temperature can

be set within a range of 17 C~ 30 C in 1 C

increments.

3. Press the

button to start the air

conditioner.

O

O

O

1. In the Auto mode, the air conditioner can logically

choose the mode of Cooling, Fan, and Heating

by sensing the difference between the actual

ambient room temperature and the set temperature

on the remote controller.

2. In the Auto mode, you can not switch the fan speed.

It has already been automatically controlled.

3. If the Auto mode is not comfortable for you, the

desired mode can be selected manually.

NOTE

1

2

3

4

MODE

SWING

TEMP

SHORTCUT

FAN

SPEED

TIMER

OFF

RESET LOCK

LED

FOLLOW ME

TIMER

ON

TURBO

SELF CLEAN

SWING

SLEEP

ON/OFF

Summary of Contents for SWB52E

Page 1: ...this manual carefully and keep it for future reference REMOTE CONTROLLER The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details last updated 27052014 Read This Manual Thank you very much for purchasing an ActronAir air conditioner Please read this owner s manual carefully before using your air condi...

Page 2: ...mote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer CAUTIONS Do not mix old and new batteries or...

Page 3: ...ours then hold steady for the next 5 hours after that the unit will stop operation This function is only available under Cooling Heating and AUTO operations O SLEEP Button Used to stop or start horizontal louvre move ment or set the desired up down air flow direction The louvre changes 6º degrees in angle for each press When pressed for more than 2 seconds the louvre will swing up and down automat...

Page 4: ... and the control will return to the initial settings RESET Button Push this button to decrease setting temper ature in a range of 17 C 30 C O O UP Button Push this button to increase setting temper ature in a range of 17 C 30 C O O DOWN Button 9 14 LOCK Button When you press the recessed LOCK button all current settings are locked in and the remote controller does not accept any operation except t...

Page 5: ... UP DOWN FAN ON OFF Ensure the unit is plugged in and power is available 1 Press the button to select COOL HEAT or FAN mode 2 Press the buttons to set the desired temperature 3 Press the button to select the fan speed in four steps Auto Low Med or High 4 Press the button to start the air conditioner The temperature can be set within a range of 17 C 30 C in 1 C increments O O O In the FAN mode the ...

Page 6: ...ER ON the last Auto on setting time and the signal H will be shown on the LCD display area Now it is ready to reset the Auto on time to START the operation 2 Push the TIMER ON button again to set desired Auto on time Each time you press the button the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours 3 After setting the TIMER ON there will be a one secon...

Page 7: ...er will stop automatically at the set time To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of stopping operation time and the signal H will show on the display area 2 Press the TIMER OFF button to display 10H on the TIMER OFF display of the remote controller 3 Wait for 3 seconds and the digital display area will show the temperature again The TIMER OFF indicat...

Page 8: ...LLOW ME function is initiated When the function is activated the remote displays the actual temperature at its location The remote control will send this signal to the air conditioner every 3 minutes interval until press the FOLLOW ME button again The Follow Me function is not available under DRY and FAN mode Switch the operation mode or turn off the unit will cancel the Follow Me function automat...

Reviews: