14
Operation Manual
LC7-2 Wall Control
Operation Manual - LC7-2 Wall Control
Document: 0525-080
Ver. 1 190923
12.03.01. Turn On the ON/OFF Button Backlight
1. Press and hold the
REPEAT
button.
2. Press and release the
button, along with the
REPEAT
button.
3. Lock
symbol will appear for 3 seconds showing that the
button backlight is set.
backlight will
remain lit.
12.03.02. Turn Off the On/Off Button Backlight
1. Press and hold the
REPEAT
button.
2. Press and release the
button, along with the
REPEAT
button.
3. Lock
symbol will appear for 3 seconds showing that the
button backlight is set.
backlight will
turn OFF
.
13. Program Menu
NOTE
• The Program Menu has a 60 second inactive timeout, once expired, display will return to the home screen.
• Program Menu
01
(7-Day Programmable Function),
02
(Clock) and
03
(Temperature Set back) can only be set via Wall
Control 1 (
C-1
). Wall Control 2 and 3 (
C-2
and
C-3
) will skip these Menu and directly proceed at Menu
04
.
13.01. 7-Day Programmable Function
13.01.01. Time clock Operation
NOTE
• The 7-Day Time clock feature of the LC7-2 control allows you to set the air conditioning system to Turn-ON and
Turn-OFF at different times for each day of the week.
• Each day can have 2-Programmed Events.
• Each event has an On and Off time.
• Ensure that the current day and time are set correctly before proceeding with programming.
• To reset any scheduled time clock events, press and hold the
PROG
and
DISP
buttons for 3 seconds.
13.01.02. Example of Time clock Operation
MON
TUE
WED
THU
FRI
SAT
SUN
EVENT 1
ON
TIME
6:00am
6:00am
6:00am
6:00am
6:00am
7:00am
8:00am
OFF TIME 10:00am 10:00am 10:00am 10:00am 10:00am
9:00am
11:00am
EVENT 2
ON
TIME
4:00pm
4:00pm
4:00pm
4:00pm
1:00pm
-:--
-:--
OFF TIME 10:00pm 10:00pm 10:00pm 10:00pm
11:00pm -:--
-:--