AGTRON  

COFFEE ROAST ANALYZER 

 E20CP-III OPERATIONS MANUAL 

 

Software Version IR128-S5.0 & IR128-S5.5 USB/ADT         

2020 

 

Special Application 

Spectrophotometer 

 
                      
 
 
 
 

AGTRON INCORPORATED

 

9395 Double “R” Boulevard 

Reno, NV  89511 

PHONE: 1-775-850-4600 

FAX:   1-775-850-4611

 

 
 
 
 
 
 

Made in the USA 

  
 

 
 
 
 
 
 
 
 

 
 
 

Summary of Contents for E20CP-III

Page 1: ...E20CP III OPERATIONS MANUAL Software Version IR128 S5 0 IR128 S5 5 USB ADT 2020 Special Application Spectrophotometer AGTRON INCORPORATED 9395 Double R Boulevard Reno NV 89511 PHONE 1 775 850 4600 FAX...

Page 2: ...in a linear manner relative to the development of the collective organic chemistry The Agtron model E20CP III evaluates changes to these selected compounds by measuring their photometric response to...

Page 3: ...THE ANALYTICAL SCALE Page 12 VIII ACCESSING EDITING THE CUSTOM SCALE VARIABLES Page 13 IX IMPROVING ANALYTICAL ACCURACY AND REPEATABILITY Page 16 X NON STANDARD SCALE CALIBRATION Page 17 XI CONNECTIN...

Page 4: ...y pulling it straight out until it hits the bumper stop Look into the chassis under the drawer There are four posts sticking up from a raised platform that is affixed to the inside bottom of the chass...

Page 5: ...a 15 watt light bulb Turn the power switch to the ON position The display should activate and begin timing a 45 minute warm up period The unit model type serial number and other information will appe...

Page 6: ...keypad KEYS ANALYZER FUNCTION 0 9 Enters numeric values and access combination key functions CAL Activates calibration routine using stored high low values no editing function F CAL Displays stored h...

Page 7: ...you wish to change the Date Time displayed Depress the key The display will show YEAR YY Using the numeric keypad enter the last two digits of the year i e 2018 would be 18 The display will show MONTH...

Page 8: ...ill show AGTRON UNIT NN Use the numeric keypad to enter the two digit number to be assigned to the unit 01 99 If you wish to exit without entering an ID number key in 00 As soon as a two digit ID numb...

Page 9: ...ed with REFERENCE COFFEE SAMPLES of known or desired score see section VIII Non Standard Scale Calibration 1 Remove the two sided Red Black Calibration Disk set and dish from its storage box IMPORTANT...

Page 10: ...he sample drawer and will store a reference value The reference value stored is used automatically to recalibrate the analyzer every time the drawer is opened The display will change to LOW REFERENCE...

Page 11: ...container and thoroughly mixing the grounds to produce homogeneity It is also important that the particle specification is consistent Overfill the shallow side of the sample dish with the homogenized...

Page 12: ...S B x S C See Section VII for programming instructions To Switch Select Scales 1 Depress SCALE Each time the SCALE button is depressed selections will toggle in a loop between Agtron Scale Gourmet Sca...

Page 13: ...score offset constant VARIABLE DEFAULT VALUES LIMITS Variable A Default 0 0000 Limits 0 00000 to 0 59998 Variable B Default 1 000 Limits 0 000 to 9 876 Variable C Default 00 00 Limits 00 00 to 98 76...

Page 14: ...played depress the FNC key To edit the B variable depress the ENTER key The display will show ENTER TO SAVE EXIT B x S B 00 000 Key in the desired B value and depress the ENTER key to save and move to...

Page 15: ...ER key to save the C value exit the custom scale variable editing subroutine and return to normal analyzer function The display will show COFFEE MODE NOTE When all of the Custom Scale variables are se...

Page 16: ...f the surface compacts compresses and cakes the grind is too fine Remember what looks like an identical surface to the eye may appear quite different to the analyzer Time from Roasting Cooling Grindin...

Page 17: ...the 3 key then depress the F CAL key The display will show OPEN SAMPLE DRAWER SET REFERENCE MODE 3 Fully open the sample drawer The display will show HIGH REFERENCE RED DISK OR SAMPLE 4 Place the ligh...

Page 18: ...ibration to that scale a With the analyzer in the COFFEE MODE fully open the sample drawer and allow the analyzer to calibrate b Place the Calibration Reference disk set into the shallow side of the d...

Page 19: ...a Terminal WARNING The E20CP III does not have serial port isolation Connecting the analyzer to a non isolated serial port can permanently damage the internal micro processor Connect the analyzer seri...

Page 20: ...smitted with the notation that the auto data transmit feature is ON With auto transmit ON each time a reading is taken the product score with time and date will be transmitted b Depress the 6 SEND DAT...

Page 21: ...E USING THE NUMERIC KEYPAD AND DEPRESS THE ENTER KEY TO ENTER THAT VALUE 8 FULLY OPEN THE SAMPLE DRAWER CAREFULLY PLACE THE DARKER SAMPLE INTO THE SAMPLE POSITION AND FULLY CLOSE THE DRAWER 9 KEY IN T...

Page 22: ...e disk set is not in use Never leave the disk set in the analyzer CLEANING THE ANALYZER INTERIOR Unplug the analyzer Remove the LIFE DISK from under the sample drawer Clean the life disk with alcohol...

Page 23: ...56 9 75 70 53 1 NO TILE Medium Light 65 49 4 65 60 45 7 NO TILE Medium 55 42 0 55 50 38 3 NO TILE Medium Dark 45 34 6 45 40 30 8 NO TILE Dark 35 27 1 35 30 23 4 NO TILE Very Dark 25 19 7 25 Extremely...

Page 24: ...CTIONS Contact Agtron for a Return for Repair authorization number RFR before sending equipment to Agtron for service Analyzers returned without an RFR will not be received Repack the equipment in the...

Page 25: ...25 XV CE CERTIFICATE DECLARATION of CONFORMITY...