ABC40UKA Manual
Page 11 of 35
Recommended Test Equipment
The following equipment or equivalent is recommended for installation and system alignment:
Equipment Type
Spectrum Analyzer
HP8563E
Digital
Voltmeter
Fluke
8050
Adapter Waveguide to coax
C or Ku-band
RF cables
With calibrated insertion loss up to 15GHz
40 dB attenuator
High Power to match HPA output.
Assortment of cables, connectors and adapters (calibrated up to 18 GHz).
Ensure that the BUC TX output power is disabled to prevent accidental transmission interference
with adjacent satellites or transponders before attempting to align or performing any other
operation involving the ODU. Before attempting any system change, carefully evaluate the possible
effects of the transmitted signal.