INFORMATIONS GÉNÉRALES

TABLE DES MATIÈRES

Description du produit                                                              18
Spécifications                                                                                  18
Stockage et mise au rebut                                                                                        18
Consignes de sécurité importantes                                 19
Caractéristiques du produit                                                                              20
Matériel d’installation (fourni)                                             20
Outils d’installation recommandés                                20
Exigences d’installation                                                                                                21
Installation électrique                                                               22
Installation de l’appareil                                                           23
Changement de la cellule ActivePure

®

                         25

Changer le ballast                                                                         26
Témoin lumineux UV/Témoin  
lumineux d’entretien                                                                 28
Pièces de rechange et service                                             28
Informations relatives à la garantie                                                       29
Déclaration FCC et partie responsable                                      30

DESCRIPTION DU PRODUIT 

Félicitations pour l’achat de votre système d’amélioration de la purification d’air activTek INDUCT 750/2000! L’unité 
se monte facilement sur le côté alimentation des conduits d’air d’un système de climatisation et de chauffage, par un 
électricien ou un professionnel du CVC, afin d’assurer une désinfection des surfaces et de l’air 24 h/24 et 7 j/7  Veuillez 
lire et suivre toutes les procédures d’entretien décrites dans le présent manuel avant de l’installer ou de le réparer 

ENTREPOSAGE ET ÉLIMINATION 

Ne pas jeter ce produit avec les ordures ménagères  Les 

déchets électriques et les produits électroniques doivent 

être recyclés de manière appropriée, conformément aux 

pratiques mises en place par votre administration locale 

 

SPÉCIFICATIONS

activTek INDUCT 750/2000

• Numéro de modèle: A1022D  (750) & A1023D (2000)
• Numéro de série: US40338B  (750) & US40663B (2000)

Technologie:

ActivePure

®

Électrique:

• Tension d’alimentation: 100/240 V; 50/60Hz
• Courant: 0,17A (750)
• Puissance: 19W  (2000)

Mécanique:

•Distribution par une unité de traitement  
   de l’air avec interrupteur de sécurité

Poids et dimensions:

• 3 lb (1,36 kg)
• 9,62 po H x 9,62 po L x 7,48 po P (750)
  (24 cm x 24 cm x 19 cm)
• 8,5 po H x 8,5 po L x 11 po P (2000)
  (24 cm x 24 cm x 28,5 cm)

Température de fonctionnement:

• 34 °F à 200 °F (1 °C — 93 °C) 

Couverture maximale recommandée  
pour un espace étroit1:

• Chaque lieu est unique et une bonne  
  configuration est aussi importante que la  
  technologie  Pour approuver la couverture dans  
  votre bâtiment, consultez votre représentant  
  commercial ou contactez le service à la clientèle  
  au 1 866 736 0503   

Garantie:

• Garantie limitée de cinq (5) ans

DBG Group Investments, LLC se réserve le droit de modifier 

des spécifications sans préavis.

Consignez des renseignements relatifs à votre nouveau activTek 
INDUCT 750/2000 here  À conserver pour référence future 

Numéro de modèle                                                                                                           

Numéro de série                                                                                                                    

Date d’achat                                                                                                                              

Distributeur ou entrepreneur indépendant :

Nom                                                                                                                                               

Numéro de téléphone                                                                                                        

Adresse                                                                                                                                         

À REMPLIR ET À CONSERVER

1  Suppose des plafonds de 8 pieds de haut  Les solutions doivent 
être personnalisées en fonction de différents facteurs, notam-
ment les capacités et les paramètres du système de CVC, le débit 
d’air en tenant compte des murs, la pression de l’air et les portes, 
ainsi que les températures et taux d’humidité de l’air ambiant, 
la densité variable, les concentrations connues de composés 
organiques volatiles et d’autres couches de protection 

Summary of Contents for INDUCT 2000

Page 1: ...READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION INDUCT 750 INDUCT 2000 Electronic Air Purification System ...

Page 2: ...750 2000 Model Number A1022D 750 A1023D 2000 Sales Number US40338B 750 US40663B 2000 Technology ActivePure Electrical Input Voltage 100 240 V 50 60Hz 0 17A 17 watts 750 0 17A 19 watts 2000 Mechanical Distribution via Air Handler Safety Switch Installed Weight Dimensions 3 lbs 1 36 kg 9 62 x 9 62 x 7 48 750 24 cm x 24 cm x 19 cm 8 5 H x 8 5 W x 11 D 2000 24 cm x 24 cm x 28 5 cm Operating Temperatur...

Page 3: ... Location for Protective Earth Line CAUTION Wiring and installation of this unit must be done by a licensed HVAC contractor or electrician failure to do so will void warranty of the product When the unit is installed in a roof mounted HVAC system the unit must be protected from the elements Read this manual in its entirety before using your activTek INDUCT750 2000 Keep out of the reach of children...

Page 4: ...olts Item US70680 4 6 32 Toggle bolt wall anchors Item US70682 RECOMMENDED INSTALLATION TOOLS 3 1 2 Hole Saw for wood or metal Utility Knife 1 4 Nut Driver Bit Drill Power Driver Tin Snips for metal ductwork Phillips Screwdriver Dust Mask 3 8 Drill Bit if installing into fiberglass ducting with toggle bolts 1 4 YOU MAY ALSO NEED CAUTION When the unit is installed in a roof mounted HVAC system the ...

Page 5: ...oof mounted HVAC system the unit must be protected from the elements 1 Unit should be installed after the air handler in the HVAC system 2 The ductwork around the installation area should be clean and dry to ensure proper adhesion of the gasket materials and any tape used 3 When installing near a furnace or heating coils run the heating system through three 3 full heating cycles to ensure the temp...

Page 6: ...al contractor only For 120V domestic units Black L1 White Neutral Green Ground For commercial units Black L1 White L2 Green Ground For International Units Brown L1 Blue L2 Green w yellow stripe Ground ELECTRICAL REQUIREMENTS Wiring of the unit into your HVAC system should be done by a licensed HVAC installer or electrical contractor only CAUTION To Reduce the Risk of Electric Shock DO NOT use in w...

Page 7: ...mal position downstream from the air handler Ensure location in duct has enough room for the mounting plate It is recommended for maximum effectiveness that the unit be placed as close to the air handler as possible Hard wiring unit into HVAC system must be done by a licensed HVAC installer or electrical contractor only When the unit is installed in a roof mounted HVAC system the unit must be prot...

Page 8: ...g plate using 8 8 self tapping screws 8 Insert unit into opening Be sure the airwill pass though the ActivePure Cell honeycomb matrix 9 Secure the unit to the mounting plate with 4 thumb nuts 10 Plug unit into working powerreceptacle NOTE Unit requires power 24 7 Do not install where power to the unit will be cycled on and off INSTALLING THE UNIT CONT 4 Cut hole in duct using 3 5 hole saw ...

Page 9: ...e new ActivePure Cell into the base unit Be sure Air Flow Honeycomb Cell direction is correct WARNING UV Light in operation disconnect unit from power cord before servicing failure to follow warnings may result in severe eye damage If the unit is hard wired be sure the power to the unit is off always follow OHSA electrical lockout safety requirements to prevent accidental release of energy during ...

Page 10: ...ALLAST 2 Open the ballast housing by removing the four 4 screws then remove the cover 1 Disconnect unplug powercord from unit PowerCord Never attempt to check operation of the ActivePure Cell s by direct observation severe eye damage can result use the indicator lamps on the bottom of the ballast only Disconnect power at the breaker or fuse panel before servicing unit always follow OSHA lockout pr...

Page 11: ...D RED BLUE BLUE BLACK WHITE GREEN A B UPPER 6 terminals Black LED wire in LED White LED wire in LED 2 Blue wires in BLUE 2 Red wires in RED LOWER 3 terminals Black power wire in BLACK White power wire in WHITE GREEN is not used NOTE UV Bulb Indicator should be lit when in operation 4 Remove the two 2 nuts securing ballast to the case Remove the ballast 5 Place new ballast into the original locatio...

Page 12: ...ctivTek INDUCT 750 2000 unit requires no periodic maintenance beyond normal replacement of the ActivePure Cell every year UV bulb has an effective life of 9 000 hours NOTE For optimal performance we recommend the replacement of the ActivePure Cell every year even if the UV lamp appears to be operating normally The UV lamp operation indicator on the face of the unit will glow when the UV lamp is in...

Page 13: ...ction sites e g eBay and craigslist The only approved Internet presence for activTek products is www activTek net To confirm warranty coverage prior to purchasing a product contact activTek at 866 736 0503 with the serial number located on the back of the unit EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTI...

Page 14: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televi...

Page 15: ...15 ...

Page 16: ...Tek Environmental 1300 Valley Drive Bristol VA 24201 www activetek net DBG Group Investments LLC 1300 Valley Drive Bristol VA 24201 866 736 0503 Assembled in U S A DBG Group Investments LLC All Rights Reserved ID_OM_750 2K_65 00752_VA 01318 ...

Page 17: ...LIRE ATTENTIVEMENT LE MANUEL AFIN D UTILISER CORRECTEMENT L APPAREIL ET D ASSURER SON FONCTIONNEMENT OPTIMAL INDUCT 750 INDUCT 2000 Système électronique de purification de l air ...

Page 18: ... 750 A1023D 2000 Numérodesérie US40338B 750 US40663B 2000 Technologie ActivePure Électrique Tension d alimentation 100 240 V 50 60Hz Courant 0 17A 750 Puissance 19W 2000 Mécanique Distribution par une unité de traitement de l air avec interrupteur de sécurité Poids et dimensions 3 lb 1 36 kg 9 62 po H x 9 62 po L x 7 48 po P 750 24 cm x 24 cm x 19 cm 8 5 po H x 8 5 po L x 11 po P 2000 24 cm x 24 c...

Page 19: ...iser cet appareil avec une rallonge MISE EN GARDE Emplacement de la mise à la terre ATTENTION Le branchement et l installation de cet appareil doivent être effectués par un fournisseur ou un électricien agréé en CVC sinon la garantie du produit sera annulée Si l appareil est installé dans un système CVC fixé sur un toit il doit être protégé des éléments Veuillez lire entièrement ce manuel avant d ...

Page 20: ...ailettes pour ancrage au mur 6 Pièce US70682 OUTILS D INSTALLATION RECOMMANDÉS Scie cloche 3 po pour bois ou métal recommandé Couteau tout usage Embout de tournevis po Perceuse visseuse électrique Pinces à couper le métal pour les conduits en métal Tournevis cruciforme Masque anti poussières Mèche de forage 3 8 po en cas d installation dans des conduits en fibre de verre avec des boulons à ailette...

Page 21: ...n système CVC fixé sur un toit il doit être protégé des éléments 1 L unité doit être installée après le système de traitement d air du système CVC 2 Le conduit autour de la zone d installation doit être propre et sec pour permettre une bonne adhérence des joints et de tout ruban utilisé 3 Pour une installation à proximité d un four ou de serpentins de chauffage faites tourner le système de chauffa...

Page 22: ... technicien certifié Pour des unités domestiques à 120V Noir L1 Blanc neutre Vert terre Pour les unités commerciales Noir L1 Blanc L2 Vert terre Pour les unités internationales Marron L1 Bleu L2 Vert à rayures jaunes Terre INSTALLATION ÉLECTRIQUE L appareil doit être installé par un fournisseur ou un électricien agréé en CVC sinon la garantie du produit sera annulée ATTENTION Afin de réduire le ri...

Page 23: ...ir Assurez vous que l emplacement dans le conduit laisse suffisamment de place pour la plaque de fixation Pour une efficacité maximale il est recommandé que l unité soit placée le plus près possible de l appareil de traitement de l air Le câblage de l appareil dans un système CVC doit être effectué par un installateur ou un électricien CVC agréé uniquement Si l appareil est installé dans un systèm...

Page 24: ...into opening Be sure the airwill pass though the ActivePure Cell honeycomb matrix 9 Secure the unit to the mounting plate with 4 thumb nuts 10 Plug unit into working powerreceptacle REMARQUE L appareil doit être branché à une source d alimentation en tout temps Ne pas installer dans un endroit où l alimentation électrique de l appareil sera coupée puis remise fréquemment INSTALLATION DE L APPAREIL...

Page 25: ...ellule ActivePure dans la base de l appareil Assurez vous que l orientation du débit d air de la cellule alvéolaire est correcte MISE EN GARDE Lampe UV en marche débrancher l appareil du cordon électrique avant l entretien le non respect de cet avertissement peut entraîner de graves lésions oculaires Si l appareil est branché assurez vous que l alimentation de l appareil est coupée suivez toujours...

Page 26: ...les quatre 4 vis et ensuite le couvercle 1 Déconnectez débranchez le cordon électrique de l appareil Cordon électrique N essayez jamais de vérifier le fonctionnement de s la cellule s ActivePure par observation directe cela peut provoquer des dommages oculaires graves utilisez les indicateurs de lampe au bas du ballast uniquement Débranchez l alimentation dans le tableau des disjoncteurs ou des fu...

Page 27: ...ACK WHITE GREEN A B HAUT 6 terminaux Fil noir LED dans LED Fil blanc LED dans LED 2 fils bleus dans BLEU 2 fils rouges dans ROUGE BAS 3 terminaux Cordon électrique noir dans NOIR Cordon électrique blanc dans BLANC Le VERT n est pas utilisé REMARQUE L indicateur de lampe UV devrait être allumé lorsque celle ci fonctionne 4 Retirez les deux 2 écrous qui retiennent le ballast au boîtier Enlevez le ba...

Page 28: ...0678 TÉMOIN LUMINEUX UV TÉMOIN LUMINEUX D ENTRETIEN Votre unité activTek INDUCT 750 2000 ne nécessite aucun entretien régulier en dehors du remplacement annuel normal de la Cellule ActivePure L ampoule UV possède une durée de vie de 9 000 heures REMARQUE Pour une performance optimale nous recommandons de remplacer la Cellule ActivePure tous les ans même si le témoin UV semble fonctionner normaleme...

Page 29: ...e aux enchères par ex eBay et craigslist Le seul site internet autorisés pour les produits activTek est www activTek net Pour confirmer la couverture de la garantie avant l achat d un produit contactez activTek au 866 736 0503 avec le numéro de série situé à l arrière de l unité EXCLUSION D AUTRES GARANTIES ET CONDITIONS AUTRES QUE CELLES EXPOSÉES NOUS N ACCORDONS AUCUNE DÉCLARATION NI GARANTIE D ...

Page 30: ...tes dans les environnements domestiques Cet équipement produit utilise et peut émettre de l énergie radiofréquence et s il n est pas installé et utilisé conformément aux consignes peut entrainer des interférences néfastes aux communications radio Toutefois nous ne pouvons pas garantir que des interférences ne se produiront pas dans une installation particulière Si cet équipement entraine des inter...

Page 31: ...31 ...

Page 32: ...Environmental 1300 Valley Drive Bristol VA 24201 www activetek net DBG Group Investments LLC 1300 Valley Drive Bristol VA 24201 1 866 736 0503 Fabriqué aux États Unis DBG Group Investments LLC Tous droits réservés ID_OM_750 2K_65 00752_VA 01318 ...

Reviews: