5.

 

F/W_SEL (J204-14) 

Select Model type according to application. 

 

 

Module Type: Open 

 

Box Type: Connect to ground 

 

 

 

Module Type 

Box Type 

Use 

Select when applied to 

SpeedDome. (Appropriate setting 

with using Visca Protocol control) 

Select when applied to Stand alone 

Camera.  (Appropriate setting with 

OSD Menu Control) 

OSD Display 

Default: Off 

Default: On 

Freeze 

Zoom In/Out does not work with 

“Freeze On” 

But, when you use Zoom/Focus 

Direct Command Zoom/Focus 

works in “Freeze On”. (Preset 

Freeze function is available.) 

When you control Zoom/Focus in 

“Freeze On”, Freeze “On” turns to 

“Off” automatically. 

Zoom Position 

when camera 

turned on 

Setting Position with 

CAM_CUSTOM Command. 

(Default: 1x) 

When the camera is rebooted, Zoom 

position goes to last position. 

Summary of Contents for AS-CAM-10LHD-A

Page 1: ... Harrier series camera Edition v2 0 Issued Date 02 November 2022 Harrier 10x Autofocus Zoom Camera LVDS EX SDI CVBS AS CAM 10LHD A issue 02 Technical Reference Manual ...

Page 2: ...ents FEATURES 3 CAUTIONS 4 SPECIFICATION 5 CONNECTORS 7 INTERFACE 10 LVDS RECEIVER CIRCUIT EXAMPLE 11 CABLE SPECIFICATIONS 12 FUNCTIONS 20 PROTOCOL 28 VISCA COMMAND LIST 33 VISCA INQUIRY COMMAND LIST 39 OSD MENU 48 CAMERA DIMENSIONS 58 ORDERING INFORMATION 59 CONTACT DETAILS 59 ...

Page 3: ...peed shutter used in dark areas DNR Digital Noise Reduction 2D 3D The DNR technology eliminates noise thus generating a distinct and clear image This camera DNR function utilizes both an adaptive 2D filter reducing noise in the brightness of the image and an adaptive 3D filter reducing noise caused by movement Privacy mask Function The privacy zone function makes it possible to make specific areas...

Page 4: ... shock Operating and storage location Avoid viewing a very bright object such as light fittings during an extended period Avoid operating or storing the unit in the following locations Extremely hot or cold places operating temperature 10 C 50 C however we recommend that the unit be used within a temperature range of 0 C 45 C Damp or dusty places Places exposed to rain Places subject to strong vib...

Page 5: ...0dB AGC off Lens Lens type 10x Day Night Zoom Lens Zoom Ratio Optical x10 Digital x32 Zoom Focal Length f 5 1mm 51mm Aperture Ratio F1 6 wide F1 8 tele Angle of View D H V Wide 64 57 34 Tele 7 1 6 2 3 5 Function Focus Focus Distance Zoom Speed Lens Refresh E Zoom Mode Auto One Push Manual Distance Wide 0 1m Tele 1 0m near focus limit can also set to 3 0 5 0 10 0 m Zoom Speed 0 Slow 7 Fast Lens Ref...

Page 6: ... Format EX SDI COMM Defect DET Off On Image Range Full Comp User System NTSC PAL HD Format 1080p 30 25 fps 1080p 60 50 fps 720p 30 25 fps 720p 60 50 fps EX SDI Off On Communication ID 1 255 Baud Rate 2400 4800 9600 19200 38400 57600 115200 Protocol Pelco P Pelco D VISCA Update Display Disp Sel Set Title Init Sel Set Init Msg Language Disp Sel Off On ID Title Zoom Ratio System Message Set Title Tex...

Page 7: ...xD 18 VBS OUT 4 TXCLKOUT 19 GND 4 NC 19 GND 5 TXOUT2 20 GND 5 GND 20 DC 12V 6 TXOUT2 21 TXOUT7 6 NC 21 DC 12V 7 TXOUT1 22 TXOUT7 7 GND 22 DC 12V 8 TXOUT1 23 TXOUT6 8 ADKEY 23 DC 12V 9 TXOUT0 24 TXOUT6 9 NC 24 DC 12V 10 TXOUT0 25 EX SDI 10 D N IN 11 GND 26 EX SDI 11 NC 12 TxD CMOS 5 V 27 TXOUT5 12 MD OUT 13 RxD 28 TXOUT5 13 485 DIR 14 DC 12V 29 TXOUT4 14 F W_SEL 15 DC 12V 30 TXOUT4 15 GND Ref USL00...

Page 8: ...ternal signal in Day Night Ext In Mode Day Mode High 3 3V Night Mode Low Ground 2 AD KEY J204 8 The external wired remote controller connecter 3 MD J204 12 Port giving signal output of Motion Detection Alarm 4 485 DIR J204 13 Port giving output of TxD RxD direction in RS 485 communication TxD High 3 3V RxD Low Ground ...

Page 9: ...when applied to Stand alone Camera Appropriate setting with OSD Menu Control OSD Display Default Off Default On Freeze Zoom In Out does not work with Freeze On But when you use Zoom Focus Direct Command Zoom Focus works in Freeze On Preset Freeze function is available When you control Zoom Focus in Freeze On Freeze On turns to Off automatically Zoom Position when camera turned on Setting Position ...

Page 10: ...ce The AS CAM 10LHD A uses the THine LVDS transmitter IC chip The THine LVDS receiver IC chip THC63LVD1024 is recommended Recommended connectors and cables Cable 42 thin coaxial cable Connector USL20 30S KEL TX THC63LVD827 THine Electronics Inc RX THC63LVD1024 THine Electronics Inc ...

Page 11: ... Harrier series camera November 2022 www activesilicon com Page 11 of 59 LVDS receiver circuit example ...

Page 12: ... Harrier series camera November 2022 www activesilicon com Page 12 of 59 Cable specifications Connecting to USL20 30S KEL 42 thin coaxial cable Binding tape ...

Page 13: ... Harrier series camera November 2022 www activesilicon com Page 13 of 59 Timing Chart 1 1080p 30 Output Timing Chart 2 1080p 25 Output Timing Chart ...

Page 14: ... Harrier series camera November 2022 www activesilicon com Page 14 of 59 3 1080p 60 Output Timing Chart 4 1080p 50 Output Timing Chart ...

Page 15: ... Harrier series camera November 2022 www activesilicon com Page 15 of 59 5 720p 30 Output Timing Chart 6 720p 25 Output Timing Chart ...

Page 16: ... Harrier series camera November 2022 www activesilicon com Page 16 of 59 7 720p 60 Output Timing Chart 8 720p 50 Output Timing Chart ...

Page 17: ...r series camera November 2022 www activesilicon com Page 17 of 59 LENS DRIVER ZOOM FOCUS IRIS D N Block Diagram 5V DSP LVDS AMP HD Digital LVDS EX SDI Analog SD CVBS DC12V TxD RxD CMOS Sensor 1 2 8 2 16M Pixel ...

Page 18: ...y 1 Zoom 1 Zoom operation cycle 200 000 cycles 2 Operation condition See below 3 Test condition Normal temperature Wide Tele 2 Focus 1 Focus operation cycle 200 000 cycles 2 Operation condition See below 3 Test condition Normal temperature Near side Far side 1 Cycle 1sec 1sec 1 Cycle ...

Page 19: ...is 1 Auto iris operation cycle 50 000 cycles 2 Operation condition See below 3 Test condition Normal temperature Open Closed 4 IRCF 1 IRCF operation cycle 50 000 cycles 2 Operation condition See below 3 Test condition Normal temperature 4 5V 0V 4 5V A B A B 1sec 1sec A 200ms B 800ms ...

Page 20: ...oming out Separate mode Optical zoom and digital zoom can be operated separately 2 Focus Auto focus mode Auto Mode Auto Focus automatically adjusts the focus position to maximize the high frequency content of the picture in a center measurement area taking into consideration the high luminance and strong contrast components Auto Mode is the normal mode for AF operation Interval Mode The mode used ...

Page 21: ...inity mode The lens is forcibly moved to a position suitable for an unlimited distance Near Limit Focus Distance Can be set in minimum range of focus 3 White balance AUTO mode This mode computes the white balance value output using color information from the entire screen It outputs the proper value using the colortemperature One push mode This is a fixed white balance mode that may be automatical...

Page 22: ...Shutter speed and Gain User can also use Digital Slow Shutter by adjusting the shutter speed Bright mode Manual User can set Iris and Gain Refer to the Exposure Control in Command List for the value range of AGC Gain Shutter Speed Iris and Exposure compensation Exposure compensation Brightness Function to offset the internal reference brightness level used in the AE mode 5 WDR Wide Dynamic Range T...

Page 23: ...Auto Mode Automatically switches the settings needed for attaching or removing the IR Cut Filter With a set level of darkness the IR Cut Filter is automatically disabled With a level of brightness the IR Cut Filter is automatically enabled IR Detection On systems equipped with an IR light the internal data of the camera is used to make the proper decisions to avoid malfunctions Ext In Mode Switche...

Page 24: ...VISCA Command Privacy related commands in Command List Mask Number mm Mask A 00h Mask X 17h Mask A has highest priority and Mask X has lowest priority Mask setting bit pp pp pp pp pp pp pp pp Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Mask X W V U T S R Q P O N M L K J I H G F E D C B A Mask Modify setting nn 00h modifying the mask size for the existing mask size 01h setti...

Page 25: ...transparency Transparency Black 00h 10h Gray Light Dark 01 h 11 h 02 h 12 h 03 h 13 h 04 h 14 h 05 h 15 h 06 h 16 h White 07 h 17 h Red 08 h 18 h Green 09 h 19 h Blue 0A h 1A h Cyan 0B h 1B h Yellow 0C h 1C h Magenta 0D h 1D h Pan Tilt angle ppp qqq Range of angle PAN 180 180 TILT 90 90 Angle resolution 360 4096 ...

Page 26: ...r the alarm activated 13 DNR Digital Noise Reduction By using both of 2D DNR space based and 3D DNR time based the amount of low illuminance noise has been significantly reduced and the signal to noise ratio S N as well as horizontal resolution has been improved resulting in a clear and sharp image display even in the dark environment If the DNR Level is set too high the camera malfunction of imag...

Page 27: ...rall CMOS pixel blemishes and mask severely flawed pixels automatically upon receiving the COMP SCAN command This feature helps to make the flaws found in CMOS images even after the camera has been powered on for some time When you use this function the lens needs to be blocked to prevent light getting into the lens 19 Custom Preset As with the position preset function the camera shooting conditio...

Page 28: ... to be returned If the Command ACK Completion communication time can be cut shorter than the 1V cycle time then every 1V cycle can receive a Command 1V cycle 30fps mode 33 3ms 60fps mode 16 7ms 25fps mode 40 0ms 50fps mode 20 0ms 2 Communication parameter Protocol VISCA Pelco D Pelco P ID 1 7 VISCA 1 255 Pelco D Pelco P Baud rate 2400 4800 9600 19200 38400 57600 115200 bps Data bit 8 Start bit 1 S...

Page 29: ...CS Stop FF ID 00 00 Don t care CS Menu Set FF ID 00 03 or 07 00 5F CS Esc FF ID 00 03 or 07 00 60 CS Up FF ID 00 08 00 XX CS Down FF ID 00 10 00 XX CS Left FF ID 00 04 XX 00 CS Right FF ID 00 02 XX 00 CS Set Zoom Preset FF ID 00 03 00 Preset ID 01 05 CS Clear Zoom Preset FF ID 00 05 00 Preset ID 01 05 CS Go to Zoom Preset FF ID 00 07 00 Preset ID 01 05 CS Focus Mode FF ID 00 2B 00 00 01 Auto 02 Ma...

Page 30: ...0 ID 01 00 00 00 AF CS Stop A0 ID 00 00 Don t care AF CS Menu Set A0 ID 00 03 or 07 00 5F AF CS Esc A0 ID 00 03 or 07 00 60 AF CS Up A0 ID 00 08 00 XX AF CS Down A0 ID 00 10 00 XX AF CS Left A0 ID 00 04 XX 00 AF CS Right A0 ID 00 02 XX 00 AF CS Set Zoom Preset A0 ID 00 03 00 Preset ID 01 05 AF CS Clear Zoom Preset A0 ID 00 05 00 Preset ID 01 05 AF CS Go to Zoom Preset A0 ID 00 07 00 Preset ID 01 0...

Page 31: ...ge R Socket Number 1 3 When command messages are sent to the camera it is normal to send the next command message after waiting for the completion message or error message to return However to deal with advanced uses the camera has three buffers memories for commands so that up to three commands including the commands currently being executed can be received When the camera receives commands it no...

Page 32: ...f communication Camera ID 1 Socket number 1 Command Inquiry command Network change message Sent from the peripheral device to the controller when a device is removed from or added to the network The address must be re set when this message is received Y0 38 FF Y 9 F Camera address 8 ...

Page 33: ...parated Stop 8x 01 04 06 00 FF Tele Variable 8x 01 04 06 2p FF p 0 Slow 7 Fast Effective separate mode Wide Variable 8x 01 04 06 3p FF x1 Max 8x 01 04 06 10 FF x1 Max Magnification switchover Effective separate mode Direct 8x 01 04 46 00 00 0p 0q FF pq D Zoom Position Effective separate mode CAM_Focus Stop 8x 01 04 08 00 FF Far Standard 8x 01 04 08 02 FF Near Standard 8x 01 04 08 03 FF Far Variabl...

Page 34: ... 01 04 44 00 00 0p 0q FF pq B Gain 0 14h CAM_Chroma Direct 8x 01 04 13 00 00 0p 0q FF pq Chroma level 0 14h CAM_AE Full Auto 8x 01 04 39 00 FF Auto exposure mode Manual 8x 01 04 39 03 FF Manual control mode Shutter Priority 8x 01 04 39 0A FF Shutter priority auto exposure mode Iris Priority 8x 01 04 39 0B FF Iris priority auto exposure mode Bright 8x 01 04 39 0D FF Bright Mode Manual control CAM_S...

Page 35: ...FF pq Start Vertical Position 0 3Ch Area End X 8x 01 04 3C 30 00 0p 0q FF pq End Horizontal Position 4 3Ah Area End Y 8x 01 04 3C 40 00 0p 0q FF pq End Vertical Position 4 40h CAM_HLC Mode 8x 01 04 32 0p FF p HLC Mode 0 Off 1 On 2 Night Only Level 8x 01 04 32 10 00 0p 0q FF pq HLC Level 0 14h Clip Color 8x 01 04 32 3p FF p HLC Color 0 Dh 0 BLK 1 6 Gray 7 WHT 8 RED 9 GRN Ah BLU Bh CYN Ch YEL Dh MAG...

Page 36: ... FF IR Detection On Off IR Detection Off 8x 01 04 6E 03 FF IR Detection Level 8x 01 04 6E 10 0p FF p IR Detection Threshold Level 0 4h CAM_AutoICRAlarm Reply On 8x 01 04 31 02 FF Auto ICR switching Alarm ON OFF Off 8x 01 04 31 03 FF Reply y0 07 04 31 02 FF ICR OFF ON y0 07 04 31 03 FF ICR ON OFF CAM_Stabilizer On 8x 01 04 34 02 FF Stabilizer ON OFF HOLD Off 8x 01 04 34 03 FF Hold 8x 01 04 34 00 FF...

Page 37: ...nnnn FF xx X position 0 27h yy Y Position 0 Eh cc Color Fixed 07 White ss NORMAL 00 INVERSE 01 BLINK 02 nnnnn Display String Max 26 char Blue Screen 8x 01 05 20 pq FF p Transparency 0 0 1 25 2 50 3 75 q Blue Screen Display 0 Off 1 On Screen Clear 8x 01 05 30 01 FF Screen All clear CAM_Mute On 8x 01 04 75 02 FF Mute ON OFF Off 8x 01 04 75 03 FF On Off 8x 01 04 75 10 FF CAM_PrivacyZone SetMask 8x 01...

Page 38: ... Start Horizontal Position 00 0Eh q Start Vertical Position 00 07 r End Horizontal Position 01 0Fh s End Vertical Position 01 08h MD Zoom Preset 8x 01 04 1E 02 FF MD Zoom Preset On 8x 01 04 1E 03 FF MD Zoom Preset Off Set MD Zoom Pos 8x 01 04 1E 10 FF Set MD Zoom preset to current zoom position Alarm Reply y0 07 04 1B 0p FF p Detection Frame Set CAM_Continuous ZoomPosReply On 8x 01 04 69 02 FF Zoo...

Page 39: ... 0p FF p AF State 0 Stop 1 Run CAM_AFTimeSettingInq 8x 09 04 27 FF y0 50 0p 0q 0r 0s FF pq Active Time rs Interval Time CAM_CompScanThrsInq 8x 09 04 19 03 FF y0 50 00 00 0p 0q FF pq White spot compensation Threshold CAM_WBModeInq 8x 09 04 35 FF y0 50 00 FF Auto y0 50 01 FF Indoor y0 50 02 FF Outdoor y0 50 03 FF One Push AWB y0 50 05 FF Manual CAM_RGainInq 8x 09 04 43 FF y0 50 00 00 0p 0q FF pq R G...

Page 40: ...Inq 8x 09 04 32 10 FF y0 50 00 00 0p 0q FF pq HLC Level 0 14h CAM_HLCColorInq 8x 09 04 32 30 FF y0 50 0p FF p HLC Color 0 Dh 0 BLK 1 6 Gray1 6 7 WHT 8 RED 9 GRN Ah BLU Bh CYN Ch YEL Dh MAG CAM_WDModeInq 8x 09 04 3D FF y0 50 02 FF WDR On y0 50 03 FF WDR Off CAM_WDLevelInq 8x 09 04 7D FF y0 50 0p FF p WDR Level 0 4 CAM_ACEInq 8x 09 04 1A FF y0 50 02 FF Adaptive Contrast Enhancement On y0 50 03 FF Ad...

Page 41: ...3 FF Off y0 05 00 FF Hold CAM_StabilizerRangeInq 8x 09 04 54 00 FF y0 50 0p FF p DIS Dzoom Range 0 10 1 20 2 30 CAM_StabilizerFilterInq 8x 09 04 54 10 FF y0 50 0p FF p DIS Filter 0 Low 1 Middle 2 High CAM_StabilizerAutoCInq 8x 09 04 54 20 FF y0 50 0p FF p Auto centering mode 0 OFF 1 Half 2 Full CAM_MemoryInq 8x 09 04 3F FF y0 50 0p FF p Last Recall Memory No CAM_MemSaveInq 8x 09 04 23 0t FF y0 50 ...

Page 42: ...ion 0100h vw Socket Number 3 CAM_ModelInq 8x 09 00 37 FF y0 50 pp pp pp qq qq FF pppppp Model Code Module Type YY465Ah Box Type YY4658h YY Custom Code standard model 00 qqqq Version CAM_MDModeInq 8x 09 04 1B FF y0 50 02 FF On y0 50 03 FF Off CAM_MDFunctionInq 8x 09 04 1C FF y0 50 0m 0n 0p 0q 0r 0s FF m Display mode n Detection Frame Set bit 0 1 bit 1 2 bit 3 3 pq Threshold Level 00 14h rs Interval...

Page 43: ...30 1 25 1 1 15 1 12 0 1 8 1 6 Iris Hex Value Iris 11 F1 7 10 F2 3 0F F2 6 0E F3 1 0D F3 4 0C F3 8 0B F4 4 0A F5 2 09 F6 6 08 F8 6 07 F11 3 06 F11 3 CLOSE 2 3 05 F11 3 CLOSE 1 3 00 Closed Bright Hex Step IRIS GAIN 1B 11 A 1A 11 9 19 11 8 18 11 7 17 11 6 16 11 5 15 11 4 14 11 3 13 11 2 12 11 1 11 11 0 10 10 0 0F 0F 0 0E 0E 0 0D 0D 0 0C 0C 0 0B 0B 0 0A 0A 0 09 09 0 08 08 0 07 07 0 06 06 0 05 05 0 00 ...

Page 44: ... B000 C000 D000 10cm E000 F000 Magnification Zoom Position x1 4000 x2 6000 x3 6A80 x4 7000 x5 7300 x6 7540 x7 76C0 x8 7800 x9 78C0 x10 7980 x11 7A00 x12 7AC0 x13 7B40 x14 7B80 x15 7BC0 x16 7C00 x17 7C40 x18 7C80 x19 7CC0 x21 7D00 x23 7D40 x25 7D80 x28 7DC0 x32 7E00 Magnification Zoom Position x1 00 x2 80 x3 AA x4 C0 x5 CC x6 D5 x7 DB x8 E0 x9 E3 x10 E6 x11 E8 x12 EB x13 ED x14 EE x15 EF x16 F0 x17...

Page 45: ...E 46 f 67 Ë 05 26 F 47 g 68 Î 06 27 G 48 h 69 Ï 07 28 H 49 i 6A Ñ 08 29 I 4A j 6B Ô 09 2A J 4B k 6C Ö 0A 2B K 4C l 6D Ù 0B 2C L 4D m 6E Û 0C 2D M 4E n 6F Ü 0D 2E N 4F o 70 ß 0E 2F O 50 p 71 à 0F 30 P 51 q 72 â 10 0 31 Q 52 r 73 ä 11 1 32 R 53 s 74 ç 12 2 33 S 54 t 75 è 13 3 34 T 55 u 76 é 14 4 35 U 56 v 77 ê 15 5 36 V 57 w 78 ë 16 6 37 W 58 x 79 î 17 7 38 X 59 y 7A ï 18 8 39 Y 5A z 7B ñ 19 9 3A Z ...

Page 46: ...3 Simplified Chinese 05 Traditional Chinese Monitoring Mode 72 06 1080p 30fps 08 1080p 25fps 09 720p 60fps 0C 720p 50fps 0E 720p 30fps 11 720p 25fps 13 1080p 60fps 14 1080p 50fps Output Enabling 73 02 Analog output disabled 03 Analog output enabled 04 Analog output auto detection LVDS mode 74 0 Single output 1 Dual output HD delay 75 0 Delay disabled 1 Delay enabled VD HD polarity 7A 0 Positive 1 ...

Page 47: ...tivesilicon com Page 47 of 59 Other Control Values Setting Value Range AF Active Time 00 0sec FFh 255sec AF Interval Time 00 0sec FFh 255sec R Gain 00 14h B Gain 00 14h Aperture Level 00 0Ah Threshold Level of ICR 00 1Ch Gap Level of ICR 00 04h ...

Page 48: ...ons can be setup using Menu Key Command of Visca protocol The menu consists of the Main Menu and Sub Menu The main menu is displayed where 7 camera functions can be selected To the push of each main menu selection the sub menu is displayed If you want to save the menu select SAVE If you don t want to save the menu select EXIT After select Power off on If you want default the menu select DFLT ...

Page 49: ...I T SAVE DFLT FOCUS Select auto focus mode AUTO ONE PUSH MANUAL DISTANCE Select minimum distance in focus between camera and object 0 1 1 0 3 0 5 0 10 0 m ZOOM SPEED Select Zoom Speed 0 Slow 7 Fast LENS REFRESH Lens origin calibrated automatically ONE PUSH ON 1 day 10days E ZOOM Select maximum digital zoom magnification OFF ON max x2 x19 x21 x23 x25 x28 x32 ZOOM PRESET Select zoom preset PRESET Se...

Page 50: ...t in SHUT P or MANUAL mode 60 50 fps mode x8 x4 x2 1 60 50 1 120 100 1 250 1 700 1 1000 1 1600 1 2500 1 5000 1 7000 1 10000 1 30000 sec 30 25 fps mode x4 x2 1 30 25 1 60 50 1 120 100 1 250 1 700 1 1000 1 1600 1 2500 1 5000 1 7000 1 10000 1 30000 sec IRIS Iris level can be set in IRIS P or MANUAL mode 0 20 DSS Select maximum DSS Digital Slow Shutter 60 50 fps mode OFF x2 x4 x8 30 25 fps mode OFF x2...

Page 51: ...ust the window size Can t use WDR and BLC at the same time When WDR On BLC is Off And when BLC is On WDR is Off BLC doesn t work in Manual Exposure Mode DAY NIGHT Select Day Night MODE AUTO EXT IN DAY NIGHT AUTO DELAY 0 255 sec THRS 0 28 Day Night switching level in Auto Mode Switching in lower lux with lower threshold level GAP LOW MID LOW MIDDLE MID HIGH HIGH Margin between Day Night switching l...

Page 52: ...OR OUTDOOR AUTO Automatically adjusts color according to the available lighting ONE PUSH It is a fixed white balance mode that may be automatically readjusted only by pressing ONE PUSH MANUAL Color can be corrected when the user increases or decreases RED GAIN or BLUE GAIN INDOOR Set color temperature to be Indoor light 3700 K OUTDOOR Set color temperature to be Outdoor light 5100 K RED GAIN Adjus...

Page 53: ...jected to the camera masking is used on the portion to prevent partial saturation on the monitor MODE OFF ON NIGHT LEVEL 0 20 steps COLOR 0 13 steps DNR Select Digital Noise Reduction OFF LOW MIDDLE HIGH AUTO MIRROR Select a flip mode OFF H V H V H You can flip the picture horizontally on the screen V You can flip the picture vertically on the screen H V You can flip the picture horizontally verti...

Page 54: ...de OFF ON GAMMA Select GAMMA 0 45 0 55 0 65 0 75 INTELLIGENCE PRIVACY Hide an area you want to hide on the screen OFF ON MASK Select mask area number 1 24 MODE Mask enable or disable OFF ON POSITION Adjust the mask position SIZE Adjust the mask size COLOR Select mask color 0 13 TRANS Select mask transparency level 0 4 M ENU FOCUS EXPOSURE W HI TE BAL I M AGE I NTELLI GENCE SPECI AL FUNC DI SPLAY E...

Page 55: ...ore sensitive to setting to low step with sensitivity POSITION Adjust the Area position SIZE Adjust the Area size INTERVAL Select the alarm interval time 0 255sec DWELL TIME Select the duration time about changing MD mode 0 255sec ZOOM PRESET Select Motion Zoom Preset Mode and Position OFF ON DIS Select Digital Image Stabilizer mode OFF ON RANGE Setting the image compensation range 10 20 30 FILTER...

Page 56: ...xed When you use this function the lens needs to be blocked from light getting into the lens IMAGE RANGE Select image bit range Full 100 Compressed 75 FULL COMP USER LEVEL Select user mode level 0 32 SYSTEM Select NTSC 30 60fps or PAL 25 50fps HD FORMAT Select Digital output 1080p 30 25 fps 1080p 60 50 fps 720p 30 25 fps 720p 60 50 fps EX SDI Select EX SDI mode OFF ON When EX SDI on and HD FORMAT ...

Page 57: ...TIO OFF ON SYSTEM MSG OFF ON MD Alarm and Wait message SET TITLE Select camera title menu Text edit max 40 characters INIT SEL Select display initial message OFF ON ID OFF ON BAUDRATE OFF ON PROTOCOL OFF ON VERSION OFF ON INIT MSG OFF ON SET INIT MSG modify initial message Text edit max 40 characters LANGUAGE Select language English Simplified Chinese Traditional Chinese Japanese Character Table o...

Page 58: ... Harrier series camera November 2022 www activesilicon com Page 58 of 59 Camera Dimensions Front Left Top Right Bottom Back ...

Page 59: ...Ethernet IP output x different variants of the camera x 1 wired regular Ethernet x 2 wireless regular Ethernet x 3 wired PoE x 4 wireless PoE CONTACT DETAILS Headquarters Active Silicon Ltd Pinewood Mews Bond Close Iver Bucks SL0 0NA UK Tel 44 0 1753 650600 Fax 44 0 1753 651661 Email info activesilicon com Website www activesilicon com North America Active Silicon Inc 479 Jumpers Hole Road Suite 3...

Reviews: