TCM-6630 Hardware User’s Manual
Speed 15
400
400
DWELL TIME
The DWELL TIME is the duration time that the speed dome will stay at the sequence point,
and the range is from <0> to <127> seconds. The speed dome will go to the next sequence
point when the DWELL TIME is up. If the setting is <0>, the speed dome will stay at this
sequence point until users manually move the speed dome.
RUN SEQUENCE
User can command the speed dome camera to run the selected Sequence line manually.
EXIT
Select the item to exit the SEQUENCE menu.
AUTOPAN
Auto-pan means rotating or scanning side-to-side motion by a speed dome camera to view an area
horizontally. The parameters can be set on this page.
AUTOPAN LINE
There are four sets of auto-pan lines built in speed dome camera. Users are able to command
the speed dome camera to do continuously panning without limit by setting the start point the
same as endpoint.
START POINT
Follow the description to set the start position of the AUTOPAN path.
1. Move the cursor to <START POINT> and press <ENTER> while <TO FIND> item flashes,
the item will turn <TO SAVE> automatically.
2. Move the speed dome to a desired position and press <ENTER> to save the position as
the start point; the cursor will move to <END POINT> automatically. Ensure to set the end
AUTOPAN
AUTOPAN LINE
1
START POINT
TO FIND
END POINT
TO FIND
DIRECTION
RIGHT
SPEED
1
RUN AUTOPAN
ENTER
EXIT
YES