8
ACT Cartridge Dust Collector
Clean Air Side
Low Pressure Side =
–
Dirty Air Side
High Pressure Side =
+
Electrical
All wiring but main power lines will be assembled by ACT. In the case of maintenance or repair, refer to below
instructions.
Refer to nameplate in control panel for proper supply voltage.
Refer to page 9 for recommended timer board settings.
———————————————————————————————————————————————————-
All wiring should be done by a certified electrician and in accordance with all local and federal codes.
Refer to the job specific electrical drawing(s) located in the panel and manual binder for detailed instructions.
Fan and timing board/solenoid wiring are to be in separate conduits.
See diagram on page 10 for 5 HP fan wiring
See diagram on page 11 for 10 HP fan wiring
1. Fan
Verify fan rotation by observing from the motor end. Another indication is poor fan performance or a
lack of air movement.
2. Control Panel
The timer board is located inside the control box, mounted on the dust collector.
Once the timer board has been installed, the pressure gauge must be connected to the dust collector
using customer supplied ¼” tubing (see figure below for low and high pressure ports). If the dust
collector is installed outside, the tubing should UV resistant.
IMPORTANT:
Prior to operating the dust collector or adjusting the settings, ensure that the
down time clean feature has been properly wired. This feature will allow the dust collector to clean itself
during shut down, which will aid in prolonging the life of the filters.
Control Box