background image

820 

N

orth Front 

S

t.

N

ew 

U

lm, M

N

 56073

Toll-Free 800 422 1316 
Phone 763 557 7162 

Fax 763 557 9731 
www.actdustcollectors.com 

Summary of Contents for LASERPACK

Page 1: ...IOM 101 1 v2 LASERPACK Installation and Operation Manual...

Page 2: ...t was performed and we were provided with the results the size of the explosion vents may be inaccurate and you may not be in compliance It is the owner operators responsibility to verify the Kst and...

Page 3: ...Operation Principle 5 Shipping and Receiving 6 Handling 6 Assembly Dust Collector Anchoring 7 Compressed Air 7 Electrical 8 Timer Board Programming 9 Maintenance Filter Replacement 12 Spark Trap Clean...

Page 4: ...ity to ensure that the equipment is correctly installed and operated It is also the user s responsibility to ensure and provide qualified personnel for the installation operation and maintenance of th...

Page 5: ...surface allowing clean air to be exhausted back into the atmosphere To remove excess dust buildup on the filters a timer board is used to sequentially open the diaphragm valves and release a pulse of...

Page 6: ...ting by the manufacturer Handling Handling should be performed by trained able and qualified personnel and be consistent with safe handling practices outlined by OSHA and local codes Review this manua...

Page 7: ...may occur to the components Prior to installation purge the compressed air lines of any dirt or buildup 1 Install the compressed air pipe line to the air manifold to either the top or bottom 1 NPT cou...

Page 8: ...agram on page 10 for 5 HP fan wiring See diagram on page 11 for 10 HP fan wiring 1 Fan Verify fan rotation by observing from the motor end Another indication is poor fan performance or a lack of air m...

Page 9: ...tput The highest output terminal value that has a wire installed in it Terminal outputs have a range from 1 22 and are found near the bottom of the timer board Time Off 10 Time On 100 High Limit 1 00...

Page 10: ...10 ACT Dust Collectors WIRING DIAGRAM 5 HP...

Page 11: ...11 ACT Dust Collectors WIRING DIAGRAM 10 HP...

Page 12: ...ccess door by pulling and lifting the cam handle 4 Once door is loose lift it off the securing hooks and set it down 5 Reach into the collector and pull out all of the filters Or work your way top dow...

Page 13: ...2 Lock out tag out power to the collector and fan 3 Access the spark trap by unbolting the spark trap cover 4 Remove any debris or buildup inside of the spark trap 5 Reinstall the spark trap cover Am...

Page 14: ...led in the rows below 2 Take a new bag and place it over the outside of the bag collar Secure the bag around the collar with the provided strap Securely tighten the strap 3 Grab the bottom of the bag...

Page 15: ...nlet box with no turning vanes mitered elbow with no vanes etc Filters at end of life Replace filters Not enough compressed air Verify that the pressure is high enough for effective cleaning set to 80...

Page 16: ...re opening closing Replace if defective If located in frigid outdoors temperatures a solenoid heater may be required Diaphragm Valve Replace worn diaphragms 1 800 422 1316 Timer board Manually pulse b...

Page 17: ...arranty does not cover any damage due to normal wear and tear including but not limited to corrosion abrasion elements and modifications This warranty covers parts only This warranty covers only the p...

Page 18: ...820 North Front St New Ulm MN 56073 Toll Free 800 422 1316 Phone 763 557 7162 Fax 763 557 9731 www actdustcollectors com...

Reviews: