720-00003.8 

  

WARNING: 

RISK OF ELECTRICAL SHOCK. 

When working with batteries, extreme caution must be 

exercised. The installation should be performed by qualified personnel. Individual safety requires plenty 
of ventilation. Remove jewelry, wear protective clothing and eye wear (safety glasses), and exercise 
caution. 

Always follow the manufacturer’s instructions for correctly installing batteries. 

CAUTION: 

RISK OF ELECTRIC SHOCK AND/OR ELECTRIC ENERGY - HIGH CURRENT LEVELS. 

Do not touch 

un-insulated battery connectors or terminals. Be sure to discharge static electricity from tools and 
technician by touching a grounded surface in the vicinity of the batteries but away from the cells and 
flame arrestors. All tools should be adequately insulated to avoid the possibility of shorting connections. 
Do not lay tools on the top of the battery. 

Package Contents and Needed Tools 

 

The BATTview package contains the following items based on the BATTview model:

 

§

 

1 x BATTview unit 

§

 

1 x Installation Manual 

§

 

3 x Threaded inserts (6-32 Flanged Press Insert-Brass) 

§

 

3 x Screws (6-32x1/4 phil pan ms) 

§

 

Dielectric grease 

§

 

2 Piercing Connectors (For BATTview Mobile model only) 

 

Items needed to install and configure BATTview: 

(NOT SUPPLIED)

 

§

 

Drill bit (3/16”) for inserts 

§

 

Drill bit (1/2”) for the Combo Probe 

§

 

Phillips head screwdriver 

§

 

Tie wraps are recommended to secure the BATTview to the battery 

§

 

RTV Silicon to seal the Combo Probe after installation 

§

 

ACT Mobile Router 

§

 

ACT Windows tablet- preferred (or windows laptop) with Quantum software  
installed 

 

BATTview Installation 

The BATTview unit has two separate battery voltage sense leads, Hall-effect current sensor and a 
combo probe that includes temperature and water level sensors as shown below, another 
temperature sensor is integrated in the negative battery voltage lead for redundancy and will 
ensure that if for any reason the internal temperature sensor gets damaged or fails, the battery 
temperature will continue to be measured and reported.  

Summary of Contents for BATTview ll Short

Page 1: ...720 00003 8 ADVANCED CHARGING TECHNOLOGIES BATTview ll Short Installation Manual ...

Page 2: ...rging Technologies All rights reserved Contact Information Advanced Charging Technologies 16855 Knott Ave La Mirada CA 90638 http www act chargers com Main 877 228 5922 Sales 877 228 5922 Service 877 228 5922 service act chargers com ...

Page 3: ...w package contains the following items based on the BATTview model 1 x BATTview unit 1 x Installation Manual 3 x Threaded inserts 6 32 Flanged Press Insert Brass 3 x Screws 6 32x1 4 phil pan ms Dielectric grease 2 Piercing Connectors For BATTview Mobile model only Items needed to install and configure BATTview NOT SUPPLIED Drill bit 3 16 for inserts Drill bit 1 2 for the Combo Probe Phillips head ...

Page 4: ...fePlus or Ametek Eclipse II Chargers ensure the PLC is disabled on the BATTview Settings Ø Clean any corrosion on the connector using a small wire brush and a mixture of baking soda and water Ø Apply a small amount of dielectric grease to the surfaces of intercell terminals before connecting the BATTview terminal The grease will help stop future corrosion while allowing the electricity to make con...

Page 5: ...e battery make sure it is installed at least 8 cells from the negative terminal as shown in the example picture below Seal the probe with RTV Silicon after inserting the probe in the battery Example BATTview ll Installed on 36V industrial battery Negative Battery Lead Positive Battery Lead Combo Probe Hall effect Current Sense Leads ...

Page 6: ...ng as shown in the pictures to the side Battery Voltage Sense Leads Piercing Connectors Using the 13 mm ratcheting wrench not supplied open the jaws of the 2 piercing connectors and clamp them on the positive RED and negative BLACK battery terminals Make sure the battery voltage sensing leads are also clamped securely to the piercing connectors Note When the BATTview powers up it will blink Blue o...

Page 7: ...anual for detailed step by step instructions to the BATTview 720 00002 BATTview Installation Manual On the Battery Settings screen please ensure you enter the battery information For BATTview mobile create a new Study to start logging the data Please refer to the full BATTview mobile installation manual for detailed step by step instructions 720 00004 BATTview Mobile Installation and Setup Manual ...

Page 8: ...00003 8 8 discrepancy in ACTview records which could prevent the ACT Support Team from providing future support Please refer to the full installation manual for step by step instructions to upload the data ...