13
Ducted Blower Indoor Units
Model
A5VDB125V
A5VDB140V
A5VDB224V
A5VDB280V
Power Supply
220V~/50Hz
380V/3N~/50Hz
Cable
Intersection
Surface(mm
2
)
Normal
1.5
2.5
TBA
Quantities
3
5
TBA
Note:
• The lead-in position of power cable must be provided a short circuit device with a sufficient capacity. This device has a contact separation of 3 mm at least.
• All cable shall be connected and fixed tightly, and connecting wires must be fixed on the line card;
• All wires must not touch the refrigerant pipes and compressors, motors and other moving parts, and all the conducting wires must undergo safety measures to
prevent water, dust, corrosion, vibration and rodents.
All above intersection surface of power wires are minimum requirements. The actual specifications Influenced by radiation, temperature, length etc, please
adjust it according to the related electric manual.
Wall Mounted Indoor Units
Model
A5VWM022W
A5VWM028W
A5VWM036W
A5VWM045W
A5VWM056W
A5VWM071W
Power Supply
220V~/50Hz
Cable
Intersection
Surface(mm
2
)
1.5
Quantities
3
Note:
• The lead-in position of power cable must be provided a short circuit device with a sufficient capacity. This device has a contact separation of 3 mm at least.
• All cable shall be connected and fixed tightly, and connecting wires must be fixed on the line card.
• All wires must not touch the refrigerant pipes and compressors, motors and other moving parts, and all the conducting wires must undergo safety measures to
prevent water, dust, corrosion, vibration and rodents.
• All above intersection surface of power wires are minimum requirements. The actual specifications Influenced by radiation, temperature, length etc, please
adjust it according to the related electric manual.
Ceiling Mounted
Model
A5VCM056V
A5VCM071V
A5VCM112V
A5VCM125V
Power Supply
220V~/50Hz
Cable
Intersection
Surface(mm
2
)
Normal
1.5
Quantities
3
Note:
• The lead-in position of power cable must be provided a short circuit device with a sufficient capacity. This device has a contact separation of 3 mm at least.
• All cable shall be connected and fixed tightly, and connecting wires must be fixed on the line card.
• All wires must not touch the refrigerant pipes and compressors, motors and other moving parts, and all the conducting wires must undergo safety measures to
prevent water, dust, corrosion, vibration and rodents.
• All above intersection surface of power wires are minimum requirements. The actual specifications Influenced by radiation, temperature, length etc, please
adjust it according to the related electric manual.