S76G/S78G Commands Set Reference
v1.6.5
July 2, 2018
35 of 73
Product Name
Version
Doc No
Date
Page
Purpose: Get frequency range and duty cycle of specified band. If a specific frequency is overlapped
with more than one band ID, the smallest band ID will be selected. The default band setting of S76G
is as following (Only 868 Band, other bands only have one Band ID 0):
Band ID
Duty Cycle
0
100 (1%)
1
100 (1%)
2
1000 (0.1%)
3
10 (10%)
4
100 (1%)
5
1 (100%)
6
1 (100%)
7
1 (100%)
8
1 (100%)
9
1 (100%)
10
1 (100%)
11
1 (100%)
12
1 (100%)
13
1 (100%)
14
1 (100%)
15
0 (0%)
Example:
mac get_dc_band 2
>> 1000
3.2.46
mac get_join_ch
Response: a list of channel ID for join request. Default:
0, 1 and 2
Purpose: Get frequency channel ID for join request. The default channel ID for join request is
0, 1
and 2
.
Example:
mac get_join_ch
>> 0 1 2
3.2.47
mac get_upcnt
Response: uplink counter that will be used at next transmission. Default:
1
Purpose: Get uplink counter that will be used at next transmission.
Example:
mac get_upcnt