ACR89U-A1 – Reference Manual
Version 1.04
www.acs.com.hk
Page 8 of 57
Offset
Field
Size
Value
Description
40
dwFeatures
4
000204B2h
ACR89 supports the following features:
•
Automatic parameter configuration
based on ATR data
•
Automatic ICC clock frequency
change according to parameters
•
Automatic baud rate change
according to frequency and FI, DI
parameters
•
Automatic PPS made by the ACR89
according to the current parameters
•
Automatic IFSD
•
Short APDU level exchange with
ACR89
44
dwMaxCCIDMessageLength
4
00000110h Maximum message length accepted by
ACR89 is 272 bytes
48
bClassGetResponse
1
FFh
Echo class of APDU in Get Response
command
49
bClassEnvelope
1
FFh
Insignificant (Short APDU exchange
level)
50
wLCDLayout
2
0815h
8 lines x 21 characters LCD
52
bPINSupport
1
03h
ACR89 supports PIN Verification and
PIN Modification
53
bMaxCCIDBusySlots
1
01h
Only 1 slot can be simultaneously busy
Note:
Standard CCID adopts little endian mode.
3.2. CCID Class-Specific Requests
ACR89’s USB communication with PC is based on command message format standard of ACR89
reader. This device shall support one CCID Class-Specific Request. Class-specific requests are sent
via Control Pipe.
3.2.1.
Command Summary
Stop any current processing command and return to a state where ACR89 is ready to accept a new
command:
bmRequestType
bRequest
wValue
wIndex
wLength
Data
00100001B
ABORT
(01h)
bSeq, bSlot
Interface
0000h
None
3.3. CCID Command Pipe BulK-Out Message
ACR89 reader follows the CCID Bulk-OUT Messages as standard CCID Rev 1.1 session 6.1. In
addition, this specification defines some extended commands for operating additional features. This
section lists the CCID Bulk-OUT Messages to be supported by ACR89. The extended commands will
be introduced in
Section 3.5