Offset
Field
Size
Value
Description
8
bError
1
Slot error register as defined in CCID
section 4.2.1
9
bClockStatus
1
value =
00h
Clock running
01h
Clock stopped in state L
02h
Clock stopped in state H
03h
Clock stopped in an unknown state
All other values are RFU.
8.2.3.
RDR_to_PC_Parameters
This message is sent by ACR33U-A1 SmartDuo in response to
PC_to_RDR_GetParameters
,
PC_to_RDR_ResetParameters
and
PC_to_RDR_SetParameters
messages.
Offset
Field
Size
Value
Description
0
bMessageType
1
82h
1
dwLength
4
Size of extra bytes of this message
5
bSlot
1
Same value as in Bulk-OUT message
6
bSeq
1
Same value as in Bulk-OUT message
7
bStatus
1
Slot status register as defined in CCID
section 4.2.1
8
bError
1
Slot error register as defined in CCID
section 4.2.1
9
bProtocolNum
1
Specifies what protocol data structure
follows.
00h
= Structure for protocol T=0
01h
= Structure for protocol T=1
The following values are reserved for
future use.
80h
= Structure for 2-wire protocol
81h
= Structure for 3-wire protocol
82h
= Structure for I2C protocol
10
abProtocolDat
aStructure
Byte
array
Protocol Data Structure as summarized
in CCID section 10.1.6