ACR122L – Communication Protocol
Version 1.03
www.acs.com.hk
Page 13 of 57
For SAM Interface 1, STX = 02h and ETX = 03h
For SAM Interface 2, STX = 12h and ETX = 13h
For SAM Interface 3, STX = 22h and ETX = 23h
HOST_to_RDR_IccPowerOff Format
Offset
Field
Size
Value
Description
0
bMessageType
1
63h
1
dDwLength
<LSB .. MSB>
4
00000000h Message-specific data length.
5
bSlot
1
00-FFh
Identifies the slot number for this
command. Default=00h.
6
bSeq
1
00-FFh
Sequence number for command.
7
abRFU
3
Reserved for Future Use.
ACR122L Response Frame Format
STX
Bulk-IN Header
(RDR_to_HOST_SlotStatus)
abData Checksum
ETX
1 Byte
10 Bytes
0 Byte
1 Byte
1 Byte
For SAM Interface 1, STX = 02h and ETX = 03h
For SAM Interface 2, STX = 12h and ETX = 13h
For SAM Interface 3, STX = 22h and ETX = 23h
RDR_to_HOST_DataBlock Format
Offset
Field
Size
Value
Description
0
bMessageType
1
81h
Indicates that a data block is being
sent from the ACR122L.
1
dwLength
<LSB .. MSB>
4
0
Size of
abData
field (0 Bytes).
5
bSlot
1
Same as Bulk-OUT Identifies the slot number for this
command.
6
bSeq
1
Same as Bulk-OUT Sequence number for
corresponding command.
7
bStatus
1
8
bError
1
9
bClockStatus
1