15.
Syntax:
i32 setPowerOnDelay(u32 val)
Description:
This function sets the Power On delay.
Parameters:
This function takes an unsigned long variable as the parameter. The range of the
Power On delay is 8 ~ 60 seconds.
Return Value:
If this function works successfully, the function returns 0, any other value stands
for error.
16.
Syntax:
i32 getShutdownDelay(u32 *val)
Description:
This function gets the Shutdown delay.
Parameters:
This function takes a pointer to an unsigned long variable as the parameter. The
delay time will be put at the memory which is pointed by the parameter ‘val’.
Return Value:
If this function works successfully, the function returns 0, any other value stands for
error.
17.
Syntax:
i32 setShutdownDelay(u32 val)
Description:
This function sets the Shutdown delay.
Parameters:
This function takes an unsigned long variable as the parameter. The range of the
delay is 120 ~ 3600 seconds.
Return Value:
If this function works successfully, the function returns 0, any other value stands
for error.