2. Power On Delay:
A. Range: 8 second to 60 seconds with 1 second increment
B. Default
Setting:
8 seconds
3. Soft Off Delay:
A. Range: 0 second to 3600 seconds with 1 second increment
B. Default
Setting:
5 seconds
4. Shutdown
Delay:
A. Range: 120 seconds to 3600 seconds with 1 second increment
B. Default
Setting:
180 seconds
5. Hard Off delay:
A. Range: 0 second to 3600 seconds with 1 second increment
B. Default
Setting:
60 seconds
6. Battery Low monitor
A. Enable or disable: If it is disable, the battery low monitor will not prohibit power on
or shut down platform due to battery low. Customers need to confirm their power
supply can support sufficient power for our system.
B. Default:
Disable
7. Battery low delta :
A. Battery low delta is a number in unit of Volt to determine the Battery low voltage.
B. Battery low voltage = Standard battery voltage (12V or 24V) – Delta. For example,
if delta is 2 Volts for a 12V vehicle, the Battery low voltage is 10 Volts.
C. Range: 0.5V to 3.0V with 0.5V increment.
Default Setting:
1.5V
8. Area “A” for Power Sub-System Model Name
9. Area “B” for Power Sub-System Firmware Revision
10. Area “C” for Power Sub-System Current Battery Voltage
26
Summary of Contents for AR-B6005
Page 1: ...1 AR B6005 Board User Manual ...
Page 8: ...2 2 Locations of I O ports Jumper settings definition 8 ...
Page 20: ...3 3 Superio Setup 20 ...
Page 23: ...3 5 Boot setup Choice boot priority 23 ...
Page 34: ...Driver Page This is the Driver Installation Page 34 ...
Page 35: ...Click the icon all the drivers will be selected 35 ...
Page 36: ...Click the icon all selected items will be cleared 36 ...
Page 38: ...Please click Yes to restart the system 38 ...
Page 43: ...Documents Page Double click on one of the items to open the manual 43 ...